Simulation of urban functional zone air temperature based on urban weather generator (UWG): a case study of Beijing, China

被引:1
|
作者
Huo, Hongyuan [1 ]
Geng, Xiaowei [1 ,6 ]
Zhang, Wenzhi [2 ]
Guo, Li [3 ]
Leng, Pei [4 ]
Li, Zhao-Liang [4 ,5 ]
机构
[1] Beijing Univ Technol, Fac Architecture Civil & Transportat Engn, Beijing, Peoples R China
[2] China Univ Geosci Beijing, Coll Earth Resources & Environm, Beijing, Peoples R China
[3] Informat Engn Univ, Inst Geospatial Informat, Zhengzhou, Peoples R China
[4] Chinese Agr Acad Sci, Inst Agr Resources & Reg Planning, Key Lab Agr Remote Sensing, Minist Agr, Beijing, Peoples R China
[5] Univ Strasbourg, ICube, CNRS, Illkirch Graffenstaden, France
[6] Beijing Univ Technol, Fac Architecture Civil & Transportat Engn, Beijing 100124, Peoples R China
基金
中国国家自然科学基金;
关键词
Urban functional zone; urban air temperature; canopy urban heat island; UWG; CLIMATE;
D O I
10.1080/01431161.2023.2201389
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
Rapid urbanization has led to many urban thermal environment problems. Most studies focus on analysing the urban thermal environment from the perspective of land-use type, and often at a large scale. Thus, research of urban spatial thermal environment at a block scale with different urban functional zone (UFZ) becomes the focus of this paper. UFZ refers to urban planning units with similar socio-economic functions, which often have similar energy consumption and outdoor thermal environment. In this paper, the urban weather generator (UWG) model is used to quantitatively analyse the spatial thermal environment of Beijing. To accurately simulate the urban thermal environment, the underlying surface used in the simulation is replaced by the finely classified underlying surface of the urban functional area. In this paper, we first use POI + OSM data to divide the functional areas of Beijing. The recognition accuracy of functional area is 85.6%. Then, the UWG model is used to simulate the temperature and humidity differences in different functional areas, and finally the corresponding urban and rural weather stations were used to validate its accuracy. The results show that the model calibration method can effectively improve the simulation accuracy of UWG thermal environment, the R-2 is increased by about 0.12, and the RMSE is reduced by about 0.84. The canopy temperature of different urban functional areas from high to low is: industrial area>commercial area>residential area>public area>road and traffic area>green space and square area. This model is more suitable for areas with relatively homogenous urban morphology and sparse urban vegetation. The thermal environment simulation results of the same urban functional area are basically the same, with slight differences in the temperature peaks, and the average temperature in the city centre is higher than that in the suburbs.
引用
下载
收藏
页码:7095 / 7118
页数:24
相关论文
共 50 条
  • [41] System Dynamics Modeling and Policy Simulation for Urban Traffic: a Case Study in Beijing
    Lei Wen
    Lu Bai
    Environmental Modeling & Assessment, 2017, 22 : 363 - 378
  • [42] The Governance of Urban Traffic Jam Based on System Dynamics: In Case of Beijing, China
    Yang, Haoxiong
    Lin, Kaichun
    Zhou, Yongsheng
    Du, Xinjian
    LTLGB 2012: PROCEEDINGS OF INTERNATIONAL CONFERENCE ON LOW-CARBON TRANSPORTATION AND LOGISTICS, AND GREEN BUILDINGS. VOL 1, 2013, : 197 - 207
  • [43] Emergy analysis of urban domestic water metabolism: A case study in Beijing (China)
    Liu, Gengyuan
    Casazza, Marco
    Hao, Yan
    Zhang, Yan
    Ulgiati, Sergio
    JOURNAL OF CLEANER PRODUCTION, 2019, 234 : 714 - 724
  • [44] Quantitative Analysis of the Determinants Influencing Urban Expansion: A Case Study in Beijing, China
    Xu, Qiurong
    Zheng, Xinqi
    Zhang, Chunxiao
    SUSTAINABILITY, 2018, 10 (05)
  • [45] Assessment of the impact of climate change on urban flooding: a case study of Beijing, China
    Ding, XingChen
    Liao, WeiHong
    Lei, XiaoHui
    Wang, Hao
    Yang, JiaLi
    JOURNAL OF WATER AND CLIMATE CHANGE, 2022, 13 (10) : 3692 - 3715
  • [46] Analysis of the urban turbidity island effect: a case study in Beijing City, China
    Luan, Qingzu
    Yang, M. Chang
    Feng, Tianqi
    Huang, Wenli
    ENVIRONMENTAL RESEARCH LETTERS, 2023, 18 (02)
  • [47] Diatoms are better indicators of urban stream conditions: A case study in Beijing, China
    Chen, Xiang
    Zhou, Weiqi
    Pickett, Steward T. A.
    Li, Weifeng
    Han, Lijian
    Ren, Yufen
    ECOLOGICAL INDICATORS, 2016, 60 : 265 - 274
  • [48] Analyzing spatial patterns of urban carbon metabolism: A case study in Beijing, China
    Yan, Zhang
    Xia, Linlin
    Xiang, Weining
    LANDSCAPE AND URBAN PLANNING, 2014, 130 : 184 - 200
  • [49] Evolving urban spatial structure and commuting patterns: A case study of Beijing, China
    Hu, Lingqian
    Sun, Tieshan
    Wang, Lanlan
    TRANSPORTATION RESEARCH PART D-TRANSPORT AND ENVIRONMENT, 2018, 59 : 11 - 22
  • [50] Urban dietary changes and linked carbon footprint in China: A case study of Beijing
    Xiong, Xin
    Zhang, Lixiao
    Hao, Yan
    Zhang, Pengpeng
    Chang, Yuan
    Liu, Gengyuan
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2020, 255