Simulation of urban functional zone air temperature based on urban weather generator (UWG): a case study of Beijing, China

被引:1
|
作者
Huo, Hongyuan [1 ]
Geng, Xiaowei [1 ,6 ]
Zhang, Wenzhi [2 ]
Guo, Li [3 ]
Leng, Pei [4 ]
Li, Zhao-Liang [4 ,5 ]
机构
[1] Beijing Univ Technol, Fac Architecture Civil & Transportat Engn, Beijing, Peoples R China
[2] China Univ Geosci Beijing, Coll Earth Resources & Environm, Beijing, Peoples R China
[3] Informat Engn Univ, Inst Geospatial Informat, Zhengzhou, Peoples R China
[4] Chinese Agr Acad Sci, Inst Agr Resources & Reg Planning, Key Lab Agr Remote Sensing, Minist Agr, Beijing, Peoples R China
[5] Univ Strasbourg, ICube, CNRS, Illkirch Graffenstaden, France
[6] Beijing Univ Technol, Fac Architecture Civil & Transportat Engn, Beijing 100124, Peoples R China
基金
中国国家自然科学基金;
关键词
Urban functional zone; urban air temperature; canopy urban heat island; UWG; CLIMATE;
D O I
10.1080/01431161.2023.2201389
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
Rapid urbanization has led to many urban thermal environment problems. Most studies focus on analysing the urban thermal environment from the perspective of land-use type, and often at a large scale. Thus, research of urban spatial thermal environment at a block scale with different urban functional zone (UFZ) becomes the focus of this paper. UFZ refers to urban planning units with similar socio-economic functions, which often have similar energy consumption and outdoor thermal environment. In this paper, the urban weather generator (UWG) model is used to quantitatively analyse the spatial thermal environment of Beijing. To accurately simulate the urban thermal environment, the underlying surface used in the simulation is replaced by the finely classified underlying surface of the urban functional area. In this paper, we first use POI + OSM data to divide the functional areas of Beijing. The recognition accuracy of functional area is 85.6%. Then, the UWG model is used to simulate the temperature and humidity differences in different functional areas, and finally the corresponding urban and rural weather stations were used to validate its accuracy. The results show that the model calibration method can effectively improve the simulation accuracy of UWG thermal environment, the R-2 is increased by about 0.12, and the RMSE is reduced by about 0.84. The canopy temperature of different urban functional areas from high to low is: industrial area>commercial area>residential area>public area>road and traffic area>green space and square area. This model is more suitable for areas with relatively homogenous urban morphology and sparse urban vegetation. The thermal environment simulation results of the same urban functional area are basically the same, with slight differences in the temperature peaks, and the average temperature in the city centre is higher than that in the suburbs.
引用
下载
收藏
页码:7095 / 7118
页数:24
相关论文
共 50 条
  • [1] Simulation of canopy urban heat island at a block scale based on local climate zones and urban weather generator: a case study of Beijing
    Zhang, Wenzhi
    Huo, Hongyuan
    Geng, Xiaowei
    Zhou, Ping
    Guo, Li
    Li, Zhao-Liang
    INTERNATIONAL JOURNAL OF REMOTE SENSING, 2023, 45 (19-20) : 7160 - 7184
  • [2] Urban functional zone classification based on self-supervised learning: A case study in Beijing, China
    Lu, Weipeng
    Qi, Ji
    Feng, Huihui
    FRONTIERS IN ENVIRONMENTAL SCIENCE, 2022, 10
  • [3] Improving urban air quality in China: Beijing case study
    Hao, JM
    Wang, LT
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2005, 55 (09) : 1298 - 1305
  • [4] An Agent-based Spatial Urban Social Network Generator: A Case Study of Beijing, China
    Zhuge, Chengxiang
    Shao, Chunfu
    Wei, Binru
    JOURNAL OF COMPUTATIONAL SCIENCE, 2018, 29 : 46 - 58
  • [5] Do Urban Functional Zones Affect Land Surface Temperature Differently? A Case Study of Beijing, China
    Feng, Yuning
    Du, Shihong
    Myint, Soe W.
    Shu, Mi
    REMOTE SENSING, 2019, 11 (15)
  • [6] A New Urban Functional Zone-Based Climate Zoning System for Urban Temperature Study
    Yu, Zhaowu
    Jing, Yongcai
    Yang, Gaoyuan
    Sun, Ranhao
    REMOTE SENSING, 2021, 13 (02) : 1 - 17
  • [7] Localized Downscaling of Urban Land Surface Temperature-A Case Study in Beijing, China
    Li, Nana
    Wu, Hua
    Ouyang, Xiaoying
    REMOTE SENSING, 2022, 14 (10)
  • [8] Evaluation of urban metabolism based on emergy synthesis: A case study for Beijing (China)
    Zhang, Yan
    Yang, Zhifeng
    Yu, Xiangyi
    ECOLOGICAL MODELLING, 2009, 220 (13-14) : 1690 - 1696
  • [9] Urban metabolism based on emergy and slack based model: A case study of Beijing, China
    Tao Song
    Jianming Cai
    Hui Xu
    Yu Deng
    Fangqu Niu
    Zhenshan Yang
    Shanshan Du
    Chinese Geographical Science, 2015, 25 : 113 - 123
  • [10] Urban Metabolism Based on Emergy and Slack Based Model: A Case Study of Beijing, China
    SONG Tao
    CAI Jianming
    XU Hui
    DENG Yu
    NIU Fangqu
    YANG Zhenshan
    DU Shanshan
    Chinese Geographical Science, 2015, 25 (01) : 113 - 123