Label-free isolation of circulating tumor cells using negative lateral dielectrophoresis-assisted inertial microfluidics

被引:1
|
作者
Mohammadi, Aliasghar [1 ]
Safari, Morteza [1 ]
Rahmanian, Mehdi [2 ]
机构
[1] Sharif Univ Technol, Dept Chem & Petr Engn, Tehran, Iran
[2] ACECR, Breast Canc Res Ctr, Interdisciplinary Technol Dept, Biomat & Tissue Engn Res Grp,Motamed Canc Inst, Tehran, Iran
关键词
SEPARATION; BLOOD; FLOW; MANIPULATION; DEVICE;
D O I
10.1007/s10404-023-02662-3
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A dielectrophoresis (DEP)-assisted inertial microfluidics method is introduced in this study for the isolation of circulating tumor cells (CTCs) from diluted blood samples. The method is based on the negative DEP, provided with the laterally allocated microelectrodes as well as the proper selection of the applied electric field frequency and voltage to suppress the limited purity arising from the overlapped sizes of CTCs and white blood cells. The dynamics of polystyrene microparticles (with the sizes of 5 and 15 & mu;m) were first investigated numerically and experimentally within the DEP-assisted inertial microfluidic device. While the dynamics of the larger microparticles were governed by the inertial and DEP forces, those of the smaller microparticles were subject to the Dean drag force. In the absence of the DEP force, the larger microparticles migrate to two stable equilibrium positions corresponding to the upper and lower walls for the microchannel cross section. In the presence of the DEP force, however, the equilibrium position corresponding to the lower wall is considerably displaced, while the top wall-associated equilibrium position remains almost intact. Finally, it was found that the proposed method outperformed the corresponding solely inertial method in terms of purity in the isolation of CTCs from diluted blood samples. For instance, at a hematocrit of 1%, the purity of isolated MDA-MB-231 cells spiked in diluted blood samples was 85.3% by the use of the solely inertial microfluidic device, while viable CTCs were captured by the DEP-assisted inertial microfluidic device with a purity of 94.1% at the total flow rate and applied voltage of, respectively, 650 & mu;L min(-1) and 50 V.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] High throughput, label-free isolation of circulating tumor cell clusters in meshed microwells
    Mert Boya
    Tevhide Ozkaya-Ahmadov
    Brandi E. Swain
    Chia-Heng Chu
    Norh Asmare
    Ozgun Civelekoglu
    Ruxiu Liu
    Dohwan Lee
    Sherry Tobia
    Shweta Biliya
    L. DeEtte McDonald
    Bassel Nazha
    Omer Kucuk
    Martin G. Sanda
    Benedict B. Benigno
    Carlos S. Moreno
    Mehmet A. Bilen
    John F. McDonald
    A. Fatih Sarioglu
    [J]. Nature Communications, 13
  • [42] High throughput, label-free isolation of circulating tumor cell clusters in meshed microwells
    Boya, Mert
    Ozkaya-Ahmadov, Tevhide
    Swain, Brandi E.
    Chu, Chia-Heng
    Asmare, Norh
    Civelekoglu, Ozgun
    Liu, Ruxiu
    Lee, Dohwan
    Tobia, Sherry
    Biliya, Shweta
    McDonald, L. DeEtte
    Nazha, Bassel
    Kucuk, Omer
    Sanda, Martin G.
    Benigno, Benedict B.
    Moreno, Carlos S.
    Bilen, Mehmet A.
    McDonald, John F.
    Sarioglu, A. Fatih
    [J]. NATURE COMMUNICATIONS, 2022, 13 (01)
  • [43] Highly efficient circulating tumor cell isolation from whole blood and label-free enumeration using polymer-based microfluidics with an integrated conductivity sensor
    Adams, Andre A.
    Okagbare, Paul I.
    Feng, Juan
    Hupert, Matuesz L.
    Patterson, Don
    Goettert, Jost
    McCarley, Robin L.
    Nikitopoulos, Dimitris
    Murphy, Michael C.
    Soper, Steven A.
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (27) : 8633 - 8641
  • [44] Label-free high throughput microfluidic device for the isolation of circulating tumor cells from breast cancer patients
    Lin, Eric
    Rivera, Lianette
    Yoon, Hyeun Joong
    Fouladdel, Shamileh
    Wieger, Jacob
    Guthrie, Stephanie
    Deol, Yadwinder S.
    Clouthier, Shawn G.
    Luther, Tahra K.
    Simeone, Diane M.
    Burness, Monika L.
    Azizi, Ebrahim
    Wicha, Max S.
    Nagrath, Sunitha
    [J]. CANCER RESEARCH, 2015, 75
  • [45] Highly efficient circulating tumor cell isolation from whole blood and label-free enumeration using polymer-based microfluidics with an integrated conductivity sensor
    Adams, André A.
    Okagbare, Paul I.
    Feng, Juan
    Hupert, Matuesz L.
    Patterson, Don
    Götten, Jost
    McCarley, Robin L.
    Nikitopoulos, Dimitris
    Murphy, Michael C.
    Soper, Steven A.
    [J]. Journal of the American Chemical Society, 2008, 130 (27): : 8633 - 8641
  • [46] Homoporous polydimethylsiloxane membrane microfilter for ultrafast label-free isolation and recognition of circulating tumor cells in peripheral blood
    Xie, Peng
    Yao, Xiaoyue
    Chu, Zhenyu
    Yang, Yang
    Li, Haifeng
    Tan, Siyuan
    Tang, Haodong
    Zhou, Jiahua
    Jin, Wanqin
    [J]. ISCIENCE, 2023, 26 (11)
  • [47] Hydrodynamic and label-free sorting of circulating tumor cells from whole blood
    Geislinger, Thomas M.
    Stamp, Melanie E. M.
    Wixforth, Achim
    Franke, Thomas
    [J]. APPLIED PHYSICS LETTERS, 2015, 107 (20)
  • [48] Biomechanics Based Microfluidic Biochip for the Label-free Isolation and Retrieval of Circulating Tumour Cells
    Lim, C. T.
    Tan, S. J.
    Lim, W. T.
    Tan, M. H.
    [J]. EUROPEAN JOURNAL OF CANCER, 2011, 47 : S48 - S48
  • [49] Hybrid magnetic and deformability based isolation of circulating tumor cells using microfluidics
    Chen, Hongmei
    Zhang, Zhichao
    Liu, Hailian
    Zhang, Zhifeng
    Lin, Changming
    Wang, Bin
    [J]. AIP ADVANCES, 2019, 9 (02)
  • [50] Evaluation of Positive and Negative Methods for Isolation of Circulating Tumor Cells by Lateral Magnetophoresis
    Kang, Haeli
    Kim, Jinho
    Cho, Hyungseok
    Han, Ki-Ho
    [J]. MICROMACHINES, 2019, 10 (06)