Predictive value of 3D ultrasound assessment of endometrial receptivity for PGD/PGS for transfer pregnancy outcome

被引:2
|
作者
Sun, Kaixuan [1 ]
Xiu, Yinling [1 ]
Wang, Yinghua [1 ]
Yu, Tingting [1 ]
Lu, Xiaoli [1 ]
Wang, Xiliang [1 ]
Yu, Yuexin [1 ]
机构
[1] Gen Hosp Northern Theater Command, Dept Reprod Med, 5 Guangrong Rd, Shenyang 110016, Liaoning, Peoples R China
关键词
PGD; PGS; Pregnancy outcome; Endometrium; Window of receptivity; 3D ultrasound; IN-VITRO FERTILIZATION; EMBRYO-TRANSFER; THICKNESS; IMPLANTATION; RATES; PROGESTERONE; EXPRESSION; CYCLES; PHASE; IVF;
D O I
10.1186/s12884-023-05534-4
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
ObjectiveTo investigate the predictive value of three-dimensional ultrasound assessment of endometrial receptivity in PGD/PGS transplantation patients on pregnancy outcome.Methods280 patients undergoing PGD/PGS transplantation were enrolled and divided into group A and group B according to the patients' pregnancy outcomes. The general conditions, endometrial receptivity indexes of the two groups were compared. Multifactorial logistic regression analysis was used to determine the factors influencing pregnancy outcome in PGD/PGS transplant patients. ROC curves were plotted to analyze the predictive value of 3D ultrasound parameters on pregnancy outcome. The results of the study were validated with patients who underwent FET transplantation, and the patients in the validation group were treated with the same 3D ultrasound examination method and treatment plan as the observation group.ResultsThe differences in basic situations between two groups were not statistically significant (P > 0.05). The percentage of endometrial thickness, endometrial blood flow, and endometrial blood flow classification type II + II were higher in group A than in group B (P < 0.05). Multifactorial logistic regression analysis showed that endometrial thickness, endometrial blood flow and endometrial blood flow classification were influencing factors of pregnancy outcome in PGD/PGS patients. The sensitivity of predicting pregnancy outcome based on the results of transcatheter 3D ultrasound was 91.18%, the specificity was 82.35%, and the accuracy was 90.00%, which has a high predictive value.Conclusion3D ultrasound can predict pregnancy outcome by assessing the endometrial receptivity of PGD/PGS transplantation, in which endometrial thickness and endometrial blood flow have a good predictive value.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Predictive value of crossover sign for outcome of ultrasound-guided vacuum aspiration in women with Cesarean scar pregnancy
    Shen, M.
    Li, L.
    Zhu, L.
    Liu, J.
    Lin, T.
    Liu, X.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2024, 63 (04) : 544 - 550
  • [42] 4D/3D ultrasound-guided embryo transfer
    Nazzaro, A.
    Salerno, A.
    Fusco, P.
    Iammarone, M.
    HUMAN REPRODUCTION, 2006, 21 : I137 - I138
  • [43] MURINE-DERIVED 3D ENDOMETRIAL ORGANOID MODEL TO INVESTIGATE THE ROLE OF NODAL SIGNALING IN UTERINE RECEPTIVITY
    Pinel, Laurie
    Dufort, Daniel
    PLACENTA, 2024, 154 : E55 - E55
  • [44] Prenatal assessment and pregnancy outcomes of foetal low-lying conus medullaris using 3D ultrasound
    Jing, Baihua
    Zhang, Huijing
    Sun, Yu
    BMC PREGNANCY AND CHILDBIRTH, 2022, 22 (01)
  • [45] Prenatal assessment and pregnancy outcomes of foetal low-lying conus medullaris using 3D ultrasound
    Baihua Jing
    Huijing Zhang
    Yu Sun
    BMC Pregnancy and Childbirth, 22
  • [46] Mean value coordinates based 3D animation transfer
    Department of Common Courses, Zhejiang Police College, Hangzhou 310053, China
    Jisuanji Fuzhu Sheji Yu Tuxingxue Xuebao, 2008, 5 (625-630):
  • [47] Endometrial volume as assessed by three-dimensional ultrasound is a predictor of pregnancy outcome after in vitro fertilization and embryo transfer
    Zollner, U
    Zollner, KP
    Specketer, MT
    Blissing, S
    Müller, T
    Steck, T
    Dietl, J
    FERTILITY AND STERILITY, 2003, 80 (06) : 1515 - 1517
  • [48] Value of 3D ultrasound in the management of suspected Asherman's syndrome
    Knopman, Jaime
    Copperman, Alan B.
    JOURNAL OF REPRODUCTIVE MEDICINE, 2007, 52 (11) : 1016 - 1022
  • [49] The value of 3D ultrasound in permanent breast seed implant brachytherapy
    Morton, Daniel
    Michael, Justin
    Batchelar, Deidre
    Hilts, Michelle
    Fenster, Aaron
    Crook, Juanita
    MEDICAL PHYSICS, 2017, 44 (08) : 4382 - 4383
  • [50] 3D ultrasound biomicroscopy (3D-UBM) imaging of the eye for unique 3D assessment of ciliary body
    Minhaz, Ahmed Tahseen
    Wu, Hao
    Helms, Richard W.
    Sevgi, Duriye Damla
    Kim, Alvin
    Kwak, Sunwoo
    Orge, Faruk H.
    Wilson, David L.
    MEDICAL IMAGING 2020: ULTRASONIC IMAGING AND TOMOGRAPHY, 2020, 11319