Diagnostic accuracy of superb microvascular imaging for detecting intraplaque neovascularization: a systematic review and meta-analysis

被引:2
|
作者
Zhao, Lina [1 ]
Han, Yubo [1 ]
Che, Yanling [1 ]
Zhang, Xuesong [1 ]
Luo, Min [1 ]
Li, Jinzhu [2 ]
机构
[1] Heilongjiang Univ Chinese Med, Affiliated Hosp 1, Dept Ultrasound Med, Harbin, Peoples R China
[2] Second Hosp Heilongjiang Prov, Dept Ultrasound Med, Harbin, Peoples R China
基金
中国国家自然科学基金;
关键词
Superb microvascular imaging (SMI); contrast-enhanced carotid ultrasonography (CEUS); carotid plaque; diagnostic accuracy; systematic review; CONTRAST-ENHANCED ULTRASOUND; STROKE RISK; SPECIFICITY; SENSITIVITY; PLAQUE; RATIO;
D O I
10.21037/cdt-23-202
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Atherosclerotic plaques can cause carotid artery stenosis, and "vulnerable plaques" can even lead to ischemic stroke. The objective of this study was to assess the accuracy of superb microvascular imaging (SMI) for the detection of carotid intraplaque neovascularization (IPN) in patients with atherosclerotic plaques. Methods: We searched the Cochrane Library, Embase, Medline, and Wanfang databases until January 17, 2023. We included original studies with information on diagnostic accuracy of SMI for the evaluation of carotid IPN. The primary outcome was the accuracy of SMI for detecting carotid IPN. A meta-analysis was performed to estimate the accuracy of each parameter. We used the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) to assess the risk of bias for each included article. Meta-regression was performed to determine items that may have contributed to heterogeneity in the sensitivity or specificity of the test. Results: This meta-analysis included 20 studies with 1,589 carotid plaques in 1,225 patients. The analysis showed a sensitivity and specificity of SMI for detecting IPN of 93% [95% confidence interval (CI): 87- 96%] and 80% (95% CI: 71-87%), respectively. The risk of bias across the QUADAS-2 domains was low. Only the proportion of dyslipidemia influenced the estimates of sensitivity and specificity. Conclusions: This review suggests that SMI has a good diagnostic performance for detecting carotid IPN. The very high sensitivity with excellent post-test probability indicated that SMI can be recommended to screen for carotid IPN among patients with carotid plaques.
引用
收藏
页码:893 / 905
页数:15
相关论文
共 50 条
  • [31] The accuracy of diagnostic imaging for the assessment of chronic osteomyelitis: A systematic review and meta-analysis
    Termaat, MF
    Raijmakers, PGHM
    Scholten, HJ
    Bakker, FC
    Patka, P
    Haarman, HJTM
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (11): : 2464 - 2471
  • [32] Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis
    Ravi Aggarwal
    Viknesh Sounderajah
    Guy Martin
    Daniel S. W. Ting
    Alan Karthikesalingam
    Dominic King
    Hutan Ashrafian
    Ara Darzi
    npj Digital Medicine, 4
  • [33] Diagnostic Accuracy of Arterial Spin-Labeling MR Imaging in Detecting the Epileptogenic Zone: Systematic Review and Meta-analysis
    Zeng, J. Y.
    Hu, X. Q.
    Xu, J. F.
    Zhu, W. J.
    Wu, H. Y.
    Dong, F. J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2021, 42 (06) : 1052 - 1060
  • [34] Diagnostic accuracy of arterial spin labeling MR imaging in detecting cerebral arteriovenous malformations: a systematic review and meta-analysis
    Hallak, Hana
    Aljarayhi, Salwa
    Abou-Al-Shaar, Hussam
    Martini, Michael
    Michealcheck, Charlotte
    Elarjani, Turki
    Bin-Alamer, Othman
    Naik, Anant
    Aldahash, Homoud
    Brinjikji, Waleed
    Lawton, Michael
    Alotaibi, Naif
    NEUROSURGICAL REVIEW, 2024, 47 (01)
  • [35] Diagnostic accuracy of OCT angiography for macular neovascularization in central serous chorioretinopathy: A systematic review and meta-analysis
    Kiilgaard, Hans Christian
    Nissen, Anne Helene Kollund
    Balaratnasingam, Chandrakumar
    Borrelli, Enrico
    Breazzano, Mark P.
    van Dijk, Elon H. C.
    Sevik, Mehmet Orkun
    Grauslund, Jakob
    Subhi, Yousif
    ACTA OPHTHALMOLOGICA, 2024, 102 (07) : 749 - 758
  • [36] Diagnostic accuracy of artificial intelligence for detecting gastrointestinal luminal pathologies: A systematic review and meta-analysis
    Parkash, Om
    Siddiqui, Asra Tus Saleha
    Jiwani, Uswa
    Rind, Fahad
    Padhani, Zahra Ali
    Rizvi, Arjumand
    Hoodbhoy, Zahra
    Das, Jai K.
    FRONTIERS IN MEDICINE, 2022, 9
  • [37] Comparison of diagnostic accuracy of Midkine and AFP for detecting hepatocellular carcinoma: a systematic review and meta-analysis
    Lu, Qingqing
    Li, Jie
    Cao, Hui
    Lv, Chenlu
    Wang, Xiaolin
    Cao, Shiqiong
    BIOSCIENCE REPORTS, 2020, 40
  • [38] Diagnostic Accuracy of IDX-DR for Detecting Diabetic Retinopathy: A Systematic Review and Meta-Analysis
    Khan, Zaid
    Gaidhane, Abhay m
    Singh, Mahendra
    Ganesan, Subbulakshmi
    Kaur, Mandeep
    Sharma, Girish chandra
    Rani, Pooja
    Sharma, Rsk
    Thapliyal, Shailendra
    Kushwaha, Monam
    Kumar, Harish
    Agarwal, Rajat kumar
    Shabil, Muhammed
    Verma, Lokesh
    Sidhu, Amritpal
    Manan, Norhafizah binti ab
    Bushi, Ganesh
    Mehta, Rachana
    Sah, Sanjit
    Satapathy, Prakasini
    Samal, Shailesh kumar
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2025, 273 : 192 - 204
  • [39] Chest CT for detecting COVID-19: a systematic review and meta-analysis of diagnostic accuracy
    Buyun Xu
    Yangbo Xing
    Jiahao Peng
    Zhaohai Zheng
    Weiliang Tang
    Yong Sun
    Chao Xu
    Fang Peng
    European Radiology, 2020, 30 : 5720 - 5727
  • [40] Diagnostic Accuracy of Monofilament Tests for Detecting Diabetic Peripheral Neuropathy: A Systematic Review and Meta-Analysis
    Wang, Fengyi
    Zhang, Jiaqi
    Yu, Jiadan
    Liu, Shaxin
    Zhang, Rengang
    Ma, Xichao
    Yang, Yonghong
    Wang, Pu
    JOURNAL OF DIABETES RESEARCH, 2017, 2017