Long-term monitoring and evaluation of drought and determining the accuracy of its indicators in western Iran

被引:1
|
作者
Khasraei, Ahmad [1 ]
Abyaneh, Hamid Zare [1 ]
Jovzi, Mehdi [2 ]
Albaji, Mohammad [3 ]
机构
[1] Bu Ali Sina Univ, Fac Agr, Dept Water Engn, Hamadan, Iran
[2] Kermanshah Agr & Nat Resources Res & Educ Ctr, Soil & Water Res Dept, AREEO, Kermanshah, Iran
[3] Shahid Chamran Univ Ahvaz, Fac Water & Environm Engn, Dept Irrigat & Drainage, Ahvaz, Iran
关键词
China-Z index; Drought; Precipitation; Rainfall anomaly; Semi-arid region; METEOROLOGICAL DROUGHT; SEMIARID REGIONS; RIVER-BASIN; INDEX RDI; PREDICTION; FREQUENCY;
D O I
10.1007/s10668-024-04608-3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The identification and evaluation of drought events are essential to prevent and reduce their effects. This event is usually monitored and evaluated using different drought indices. This study aims to investigate the trend of rainfall, monitoring, and evaluation of drought in the western part of Iran. In this paper, five cities Orumiyeh, Sanandaj, Hamedan, Khorramabad, and Ilam, which are located in the west of Iran, were evaluated and monitored with the standardized precipitation index (SPI), percent of normal index (PNI), China-Z index (CZI), deciles index (DI), modified CZI (MCZI), Z-score index (ZSI), and rainfall anomaly index (RAI). The results showed that the annual rainfall in 11 years (2008-2018) in Sanandaj, Khorramabad, and Ilam stations was less than their average long-term annual rainfall, which was 415, 475, and 511 mm, respectively. The annual rainfall in 10 years (2009-2018) in Hamedan and Orumiyeh stations was less than their average long-term annual rainfall, which was 299 and 310 mm, respectively, during this decade of drought. The evaluation of indices in a long-term period showed that monitoring with the SPI in semi-humid and semi-arid climates was more accurate than the other indices. The CZI was ranked second in importance in these climates due to the high correlation of 93%.
引用
收藏
页数:24
相关论文
共 50 条
  • [41] The long-term vascular access patency and the effect of its monitoring
    Berdych, M
    Taborsky, P
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2005, 20 : V151 - V151
  • [42] Evaluation of dry textile electrodes for long-term electrocardiographic monitoring
    Alizadeh-Meghrazi, Milad
    Ying, Binbin
    Schlums, Alessandra
    Lam, Emily
    Eskandarian, Ladan
    Abbas, Farhana
    Sidhu, Gurjant
    Mahnam, Amin
    Moineau, Bastien
    Popovic, Milos R.
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2021, 20 (01)
  • [43] Evaluation of dry textile electrodes for long-term electrocardiographic monitoring
    Milad Alizadeh-Meghrazi
    Binbin Ying
    Alessandra Schlums
    Emily Lam
    Ladan Eskandarian
    Farhana Abbas
    Gurjant Sidhu
    Amin Mahnam
    Bastien Moineau
    Milos R. Popovic
    [J]. BioMedical Engineering OnLine, 20
  • [44] Experiences in long-term evaluation of mercury emission monitoring systems
    Cheng, Chin-Min
    Lin, Hung-Ta
    Wang, Qiang
    Chen, Chien-Wei
    Wang, Chia-Wei
    Liu, Ming-Chung
    Chen, Chi-Kuan
    Pan, Wei-Ping
    [J]. ENERGY & FUELS, 2008, 22 (05) : 3040 - 3049
  • [45] Smartwatch: Performance Evaluation for Long-Term Heart Rate Monitoring
    Dung Phan
    Siong, Yee Lee
    Pathirana, Pubudu N.
    Seneviratne, Aruna
    [J]. 2015 INTERNATIONAL SYMPOSIUM ON BIOELECTRONICS AND BIOINFORMATICS (ISBB), 2015, : 144 - 147
  • [46] Evaluation of a long-term amphibian monitoring protocol in Central America
    Kaiser, Kristine
    [J]. JOURNAL OF HERPETOLOGY, 2008, 42 (01) : 104 - 110
  • [47] Evaluation of long-term voltage dip monitoring in the distribution system
    Tesarova, Miloslava
    Kaspirek, Martin
    [J]. PROCEEDINGS OF THE 7TH INTERNATIONAL SCIENTIFIC SYMPOSIUM ON ELECTRICAL POWER ENGINEERING (ELEKTROENERGETIKA 2013), 2013, : 268 - 271
  • [48] Long-term monitoring and evaluation in Spanish National Parks Network
    Bonache, J.
    de Mingo-Sancho, G.
    Serrada, J.
    Amengual, P.
    Perales, J.
    Martinez, R.
    Rodado, S.
    Albornos, E.
    [J]. ECOSISTEMAS, 2016, 25 (01): : 31 - 48
  • [49] EVALUATION OF SHORT AND LONG-TERM CHANGES IN ASTRA ELECTRODES AND THE EFFECT ON ACCURACY
    KESSNER, A
    KELLEY, ML
    BOWERS, GN
    [J]. CLINICAL CHEMISTRY, 1980, 26 (07) : 1032 - 1033
  • [50] Long-term accuracy surveillance of a system for self-monitoring of blood glucose
    Freckmann, G.
    Baumstark, A.
    Jendrike, N.
    Leucht, T.
    Wintergerst, P.
    Rittmeyer, D.
    Pleus, S.
    [J]. DIABETOLOGIA, 2015, 58 : S448 - S448