Validated portable device for the qualitative and quantitative electrochemical detection of MDMA ready for on-site use

被引:5
|
作者
Van Echelpoel, Robin [1 ,2 ]
Parrilla, Marc [1 ,2 ]
Sleegers, Nick [1 ,2 ]
Shanmugam, Saranya Thiruvottriyur [1 ,2 ]
van Nuijs, Alexander L. N. [3 ]
Slosse, Amorn [4 ]
Van Durme, Filip [4 ]
De Wael, Karolien [1 ,2 ]
机构
[1] Univ Antwerp, Dept Bioengn, A Sense Lab, Groenenborgerlaan 171, B-2020 Antwerp, Belgium
[2] Univ Antwerp, NANOlab Ctr Excellence, Groenenborgerlaan 171, B-2020 Antwerp, Belgium
[3] Toxicol Ctr, Dept Pharmaceut Sci, Univ Pl 1, B-2610 Antwerp, Belgium
[4] Natl Inst Criminalist & Criminol NICC, Vilvoordsesteenweg 100, B-1120 Brussels, Belgium
关键词
Electrochemical sensors; Qualitative detection; Quantitative detection; Smartphone application; MDMA detection; ECSTASY; PHARMACOLOGY; COCAINE; ORIGIN; MDA;
D O I
10.1016/j.microc.2023.108693
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Identifying and quantifying 3,4-methylenedioxymethamphetamine (MDMA) on-site in suspected illicit drug samples, whether it be at recreational settings or manufacturing sites, is a major challenge for law enforcement agencies (LEAs). Various analytical techniques exist to fulfil this goal, e.g. colourimetry and portable spectro-scopic techniques, each having its specific limitations (e.g. low accuracy, fluorescence, no quantification) and strengths (e.g. fast, easy to use). In this work, for the first time, an electrochemical MDMA sensor is presented to become a detection tool that can realistically be used on-site. More specifically, the use of a single buffer solution and an unmodified screen-printed electrode, along with the integration of a data analysis algorithm and mobile application permits the straightforward on-site identification and quantification of MDMA in suspicious samples. Multiple studies investigating different parameters, including pH, concentration, reproducibility, temperature and binary mixture analyses, were executed. To fully understand all the occurring redox processes, liquid chromatography coupled with high-resolution mass spectrometry analysis of partially electrolyzed MDMA samples was performed unravelling oxidation of the methylenedioxy group. Validation of the methodology was executed on 15 MDMA street samples analysed by gas chromatography coupled with mass spectrometry and compared with the performance of a commercial portable Raman and Attenuated Total Reflection Fourier Transform Infrared Spectroscopy (ATR-FTIR) device. The novel methodology outperformed the spectroscopic techniques, correctly identifying all 15 street samples. Additionally, the electrochemical sensor predicted the purity of the tablets with a mean absolute error of 2.3%. Overall, this new, electrochemical detection strategy provides LEAs the rapid, low-cost, on-site detection and quantification of MDMA in suspicious samples, without requiring specialized training.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] On-Site Electrochemical Detection of Corrosion in Substation Grounding System
    Yu, Ben
    Zhao, Peng
    Cai, Yuhang
    Yuan, Weiming
    Yu, Jinshan
    Tan, Yu
    [J]. ENERGIES, 2024, 17 (16)
  • [32] Development of a portable test device for assessing on-site floor slipperiness:: an interim report
    Grönqvist, R
    Hirvonen, M
    Rajamäki, E
    [J]. APPLIED ERGONOMICS, 2001, 32 (02) : 163 - 171
  • [33] QuickAnalysis: A Software Designed and Developed for a Portable On-Site Pathogen Detection System
    Liao, Pei
    Fang, Yile
    Chen, Hui
    Wu, Yanqi
    Deng, Yan
    Chen, Zhu
    He, Nongyue
    Liu, Hongna
    Li, Song
    [J]. JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2019, 19 (04) : 2054 - 2059
  • [35] A spore-based portable kit for on-site detection of fluoride ions
    Qin, Yuqing
    Faheem, Aroosha
    Hu, Yonggang
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2021, 419
  • [36] Optical design of portable Raman spectrometer based on-site rapid detection
    Luo, Weibo
    Yang, Jianfeng
    [J]. ICOSM 2020: OPTOELECTRONIC SCIENCE AND MATERIALS, 2020, 11606
  • [37] A smartphone-based quantitative detection device integrated with latex microsphere immunochromatography for on-site detection of zearalenone in cereals and feed
    Li, Xiangmei
    Wang, Jin
    Yi, Changqing
    Jiang, Lelun
    Wu, Jinxiao
    Chen, Xiaomin
    Shen, Xing
    Sun, Yuanming
    Lei, Hongtao
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2019, 290 : 170 - 179
  • [38] Early on-site detection of strawberry anthracnose using portable Raman spectroscopy
    Kim, Soogeun
    Hong, Sang-Hyun
    Kim, Joon Heon
    Oh, Myoung-Kyu
    Eom, Tae Joong
    Park, Yang Ho
    Shin, Gil Ho
    Yim, Sang-Youp
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2023, 303
  • [39] On-site detection of TNT in groundwater using a portable fiber optic immunosensor
    Donner, BL
    ShriverLake, LC
    Ligler, FS
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 211 : 40 - ENVR
  • [40] A Portable Array Visualization Device Integrating Sample Preparation and Detection All-in-One for the On-Site Analysis of Complex Samples
    Li, Dan
    Huo, Zhiming
    Xia, Ling
    Xiao, Xiaohua
    Li, Gongke
    [J]. ANALYTICAL CHEMISTRY, 2024, 96 (14) : 5368 - 5374