Theoretical performance studies on environment friendly refrigerants used in refrigeration units

被引:1
|
作者
Kumma, Nagarjuna [1 ]
Seethala, Gokul Sai [1 ]
Bhagat, Yatna [1 ]
Sarath, Sai [2 ]
Kruthiventi, Satya Sai Harish [1 ]
机构
[1] Natl Inst Technol Tiruchirappalli, Dept Mech Engn, Low Temp Lab, Trichy 620015, India
[2] Koneru Lakshmaiah Educ Fdn, Dept Mech Engn, Guntur 522502, Andhra Pradesh, India
关键词
Exergy; Flammability; Eco-friendly; Minimum Inert Concentration; Domestic refrigeration units; FLAME RETARDANTS; R134A; FLAMMABILITY; MIXTURES; ALTERNATIVES; REPLACEMENT; R1234YF; SYSTEM; R404A; HFC;
D O I
10.1007/s11356-023-26409-3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
European Union regulations stipulate that household refrigeration systems must operate with fluid refrigerants that possess low global warming potential (GWPs). In this work, theoretical performance of six binary and one ternary mixture (which consists of R13I1, R290, R161, R32, R1234yf, and R1234ze(E)) was investigated. The performance parameters such as coefficient of performance (COP), refrigeration effect (RE), volumetric cooling capacity (VCC), discharge temperature, pressure ratio, and specific power consumption of all considered refrigerant mixtures is studied with respect to the evaporator temperature range of -18 to 18(0)C and the condenser temperature range of 40 to 55(0)C. The properties corresponding to different operating conditions for the refrigerants considered in this study are estimated using REFPROP 10. The findings demonstrated that, when compared to R134a, all the investigated refrigerants exhibited very low specific power consumption (apart from M9, M10, and M14-M16), and high volumetric cooling capacity (VCC) (apart from M11 and M13) under the operating conditions of evaporator temperature -18(0)C and condenser temperature 40(0)C. M1-M3 and M11-M13 gave similar and within 10% deviation in coefficient of performance, while M3 and M11-M13 refrigerant mixtures offer significantly low discharge temperatures when compared to R134a. Refrigerant mixtures M2 and M11 consistently exhibited a better performance in comparison to R134a in the aspect of majority of the performance parameters considered in this study. Finally, it is understood that M2 and M11 are two possible alternative refrigerants to conventional refrigerants used in small refrigeration units (R134a and R22). Further, it is also identified that these mixtures are non-flammable, possess zero ODP and low GWP values.
引用
收藏
页码:63065 / 63083
页数:19
相关论文
共 50 条
  • [41] Thermodynamic Assessment of Using Water as a Refrigerant in Cascade Refrigeration Systems With Other Environmentally Friendly Refrigerants
    Alkhulaifi, Yousif M.
    Mokheimer, Esmail M. A.
    [J]. JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2022, 144 (02):
  • [42] An Overview of Environment-Friendly Refrigerants for Domestic Air Conditioning Applications
    Uddin, Kutub
    Saha, Bidyut Baran
    [J]. ENERGIES, 2022, 15 (21)
  • [43] Comparative study of the performance of an ejector refrigeration cycle operating with various refrigerants
    Sun, DW
    [J]. ENERGY CONVERSION AND MANAGEMENT, 1999, 40 (08) : 873 - 884
  • [44] Investigation on performance of ejector and optimal refrigerants for solar ejector refrigeration system
    Zhang, Yufeng
    Zhao, Wei
    Tian, Qi
    Sun, Yuexia
    [J]. Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2007, 28 (02): : 130 - 136
  • [45] Performance of Non-CFC Refrigerants for Low-Temperature Refrigeration
    Rajapaksha, Leelananda
    [J]. ENGINEER-JOURNAL OF THE INSTITUTION OF ENGINEERS SRI LANKA, 2009, 42 (02): : 25 - 32
  • [46] A review on the performance of nanoparticles suspended with refrigerants and lubricating oils in refrigeration systems
    Saidur, R.
    Kazi, S. N.
    Hossain, M. S.
    Rahman, M. M.
    Mohammed, H. A.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (01): : 310 - 323
  • [47] NEW TRENDS IN THE NATURAL AND MIXED REFRIGERANTS USED IN AIR CONDITIONING AND REFRIGERATION SYSTEMS - A REVIEW
    Kabeel, A. E.
    Abdelgaied, Mohamed
    Almagar, Ali M.
    [J]. 9TH INTERNATIONAL CONFERENCE ON COMPRESSORS AND COOLANTS, 2017, : 213 - 221
  • [48] Comparison of the flow characteristics and performance of low-GWP refrigerants in expansion capillary used in air conditioning units
    Barbhuiya, S. H.
    Prasad, K.
    Kruthiventi, S. S. H.
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2024,
  • [49] Refrigeration Linde-Hampson Machine at 90K Operation by Use of Ozone Friendly Refrigerants
    Dalakov, Petar
    Klier, Juergen
    Rozhentsev, Andrey
    [J]. 15TH CRYOGENICS 2019 IIR INTERNATIONAL CONFERENCE, 2019, : 45 - 52
  • [50] Alternative refrigerants in vapour compression refrigeration cycle for sustainable environment: a review of recent research
    Bhatkar, V. W.
    Kriplani, V. M.
    Awari, G. K.
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2013, 10 (04) : 871 - 880