Effect of mechanical loading on osseointegration combined with degradation behavior of magnesium bone screw in vivo

被引:5
|
作者
Gao, Yuanming [1 ,2 ]
Huang, Huiwen [1 ]
Jiang, Xiong [1 ]
Ha, Tong [1 ]
Li, Yinghui [3 ]
Zhang, Kuo [4 ]
Wang, Chao [1 ]
Wang, Lizhen [1 ]
Fan, Yubo [1 ,2 ]
机构
[1] Beihang Univ, Beijing Adv Innovat Ctr Biomed Engn, Sch Biol Sci & Med Engn, Key Lab Biomech & Mechanobiol,Minist Educ, Beijing 100083, Peoples R China
[2] Beihang Univ, Sch Engn Med, Beijing 100083, Peoples R China
[3] Beijing 2 Middle Sch, Beijing 100176, Peoples R China
[4] Peking Univ, Hlth Sci Ctr, Dept Lab Anim Sci, Beijing 100191, Peoples R China
基金
中国国家自然科学基金;
关键词
High-purity magnesium; Dynamic loading; Degradation behavior; Osseointegration; Mechanical properties; ELASTIC-MODULUS; ALLOY STENT; CORROSION; IMPLANTS; STRAIN; STRESS; VITRO; MG; FRACTURE; EXERCISE;
D O I
10.1016/j.apmt.2023.101793
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Mechanical environment is one of the critical factors that affect the degradation and osseointegration perfor-mance of magnesium-based orthopedic implants. In this study, the effects of in vivo static and dynamic loadings on osseointegration and biodegradation behavior of magnesium screw were investigated and compared. A total of 54 male New Zealand White rabbits were divided into three groups randomly, with their femoral condyles implanted with high-purity magnesium screws (Implanted Group), only drilled holes (Drilled Group) or without any surgery (Healthy Group) respectively. Half of the rabbits in each group stayed in cages all the time (as static subgroup), while the rest performed treadmill exercise (as dynamic subgroup). Dynamic loadings during rabbits' exercise were obtained based on kinematic analysis. Femoral condyles implanted with screws in Implanted Group were harvested at 8, 12 and 16 weeks after surgery to evaluate the biodegradation behavior and osseointegration. To compare the mechanical property of bone tissues, three femoral condyles of each subgroup in Implanted, Drilled, and Healthy groups were randomly selected to perform nanoindentation testing at 8, 12 and 16 weeks. Dynamic loading improved osseointegration performance obviously but did not affect the biodegradation behavior of magnesium screws. Elastic moduli of new-born bone surrounding magnesium bone screws were higher in the dynamic groups than that in static groups. Metabolism of released Mg ions from bone screw was normal both under static and dynamic loadings. The effects of mechanical loadings on osseointe-gration combined with degradation of magnesium screws in vivo were understood deeply in this study, providing guidance for patient's rehabilitative exercise postoperatively.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] In vitro fatigue behavior and in vivo osseointegration of the auxetic porous bone screw
    Wang, Lizhen
    Huang, Huiwen
    Yuan, Hao
    Yao, Yan
    Park, Jeong Hun
    Liu, Jinglong
    Geng, Xuezheng
    Zhang, Kuo
    Hollister, Scott J.
    Fan, Yubo
    ACTA BIOMATERIALIA, 2023, 170 : 185 - 201
  • [2] In vivo study of magnesium plate and screw degradation and bone fracture healing
    Chaya, Amy
    Yoshizawa, Sayuri
    Verdelis, Kostas
    Myers, Nicole
    Costello, Bernard J.
    Chou, Da-Tren
    Pal, Siladitya
    Maiti, Spandan
    Kumta, Prashant N.
    Sfeir, Charles
    ACTA BIOMATERIALIA, 2015, 18 : 262 - 269
  • [3] The Bone Buttress Theory: The Effect of the Mechanical Loading of Bone on the Osseointegration of Dental Implants
    Chavarri-Prado, David
    Brizuela-Velasco, Aritza
    Alvarez-Arenal, Angel
    Dieguez-Pereira, Markel
    Perez-Pevida, Esteban
    Viteri-Agustin, Iratxe
    Estrada-Martinez, Alejandro
    BIOLOGY-BASEL, 2021, 10 (01): : 1 - 15
  • [4] Cancellous Bone Osseointegration Is Enhanced by In Vivo Loading
    Willie, Bettina M.
    Yang, Xu
    Kelly, Natalie H.
    Han, Jane
    Nair, Turya
    Wright, Timothy M.
    van der Meulen, Marjolein C. H.
    Bostrom, Mathias P. G.
    TISSUE ENGINEERING PART C-METHODS, 2010, 16 (06) : 1399 - 1406
  • [5] Effect of mechanical stresses on degradation behavior of high-purity magnesium in bone environments
    Yao, Yan
    Xia, Jie
    Wang, Lizhen
    Gao, Yuanming
    Ding, Xili
    Wang, Chao
    Fan, Yubo
    JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2024, 171 : 252 - 261
  • [6] Corrosion degradation behavior of Mg?Zn?Zr bone screw in vitro and vivo
    Li Yufeng
    Sun Xiaohao
    Yu Xiao
    Liu Debao
    Chen, Minfang
    MATERIALS RESEARCH EXPRESS, 2019, 6 (11)
  • [7] Biocompatibility, Degradation Behavior, and Mechanical Properties of Magnesium Alloy Plates In Vivo
    Wang, Yongping
    Qin, Qingqing
    Liu, Xiaorong
    Li, Qiangqiang
    Zhang, Huaibin
    Yang, Dubin
    Jiang, Yao
    APPLIED BIONICS AND BIOMECHANICS, 2023, 2023
  • [8] In Vivo Degradation Behavior of Magnesium Alloy for Bone Implants with Improving Biological Activity, Mechanical Properties, and Corrosion Resistance
    Jian, Shun-Yi
    Lin, Chiu-Feng
    Tsai, Tung-Lin
    Wang, Pei-Hua
    Chen, Chung-Hwan
    Lin, Sung-Yen
    Tseng, Chun-Chieh
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2023, 24 (02)
  • [9] No effect of verapamil on the local bone response to in vivo mechanical loading
    Samnegård, E
    Cullen, DM
    Akhter, MP
    Kimmel, DB
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2001, 19 (02) : 328 - 336
  • [10] Ultrasound mimics the effect of mechanical loading on bone formation in vivo on rat ulnae
    Perry, Mark J.
    Parry, Laura K.
    Burton, Victoria J.
    Gheduzzi, Sabina
    Beresford, Jon N.
    Humphrey, Victor F.
    Skerry, Tim M.
    MEDICAL ENGINEERING & PHYSICS, 2009, 31 (01) : 42 - 47