The Effect of Boundary Conditions on the Wall Ends on Temperature Conditions and Effectiveness of Heat Exchangers with Parallel Flow of Heat Carriers

被引:1
|
作者
Valueva, E. P. [1 ]
机构
[1] Natl Res Univ, Moscow Power Engn Inst, Moscow 111250, Russia
基金
俄罗斯科学基金会;
关键词
heat exchanger; effectiveness; wall axial heat conduction; number of heat-transfer units; heat transfer; Biot number; CONDUCTION; PERFORMANCE;
D O I
10.1134/S0040601523100105
中图分类号
O414.1 [热力学];
学科分类号
摘要
The effect of heat conduction through the wall along the flow of heat carriers on the effectiveness of heat exchangers (HEs) when the wall ends are not thermally insulated from the environment has been investigated. An analytical solution of the problem for cocurrent flow of heat carriers was obtained for the same ratios of thermal equivalents of the heat carriers beta and heat-transfer coefficients alpha on both sides of the wall separating hot and cold heat carriers and for a counter flow at beta = alpha = 1. The solution to the problem depends on the number of heat-transfer units Ntu, parameter C(A )describing the axial wall heat conduction, the Biot number Bi, which determines relative heat transfer from the wall ends to the environment, and temperatures of the fluid in contact with the wall ends. The effect of axial wall heat conduction becomes more pronounced with decreasing parameter C-A. Two cases are examined: case I with surrounding fluid temperatures assumed as equal to the inlet and outlet temperatures of the hot heat carrier and case II with surrounding fluid temperatures assumed as equal to the inlet and outlet temperatures of the cold heat carrier. The results obtained demonstrate that, at low Biot numbers (Bi < 10(-3)), the effectiveness of a heat exchanger epsilon for any values of CA in a cocurrent HE hardly differs at all from the effectiveness of the HE in the absence of the axial wall heat conduction effect, epsilon(0), and for a counter flow at low C-A the HE effectiveness is noticeably less than epsilon(0) and decreases by two times at Ntu >> 1. At high Biot numbers (Bi > 1), the effect of axial wall conduction can increase the effectiveness of either heat carrier, while the temperature of the other heat carrier will change slightly during its flow through the heat exchanger. The predictions indicate that the best way for increasing the HE effectiveness is to employ the same thermal equivalents of two heat carriers and heat-transfer coefficients on both sides of the wall separating the hot and the heat carriers (beta = alpha = 1).
引用
收藏
页码:777 / 786
页数:10
相关论文
共 50 条
  • [41] Friction and Heat transfer in Slip flow Boundary Layer at Constant Heat Flux Boundary Conditions
    Yazdi, M. H.
    Abdullah, S.
    Hashim, I.
    Zaharim, A.
    Sopian, K.
    MATHEMATICAL METHODS, COMPUTATIONAL TECHNIQUES, NON-LINEAR SYSTEMS, INTELLIGENT SYSTEMS, 2008, : 207 - +
  • [43] Turbulent Heat Transfer in Parallel Flow Boundary Layers With Streamwise Step Changes in Surface Conditions
    Lindberg, W. R.
    Lee, R. C.
    Smathers, L. B.
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1989, 111 (1-4): : 1093 - 1096
  • [44] Viscous fluid flow and heat transfer past a permeable wall jet with convective boundary conditions
    Aly, Emad H.
    Usafzai, Waqar Khan
    Merkin, John H.
    Pop, Ioan M.
    MULTIDISCIPLINE MODELING IN MATERIALS AND STRUCTURES, 2024, 20 (04) : 658 - 670
  • [45] Heat transfer characteristics of parallel and counter flow micro-channel heat exchangers with varying wall resistance
    Maqableh, A. M.
    Khadrawi, A. F.
    Al-Nimr, M. A.
    Ammourah, S. A.
    Benim, A. C.
    PROGRESS IN COMPUTATIONAL FLUID DYNAMICS, 2011, 11 (05): : 318 - 328
  • [46] Formulas for Checking Calculations of Heat Exchangers with Crosswise Flow of Heat Carriers.
    Krasnoshchekov, L.F.
    1600,
  • [47] ROUGH-WALL TURBULENT HEAT-TRANSFER WITH STEP-WALL TEMPERATURE BOUNDARY-CONDITIONS
    TAYLOR, RP
    HOSNI, MH
    GARNER, JW
    COLEMAN, HW
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 1992, 6 (01) : 84 - 90
  • [48] Application of effectiveness-NTU relationship to parallel flow microchannel heat exchangers subjected to external heat transfer
    Mathew, B.
    Hegab, H.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2010, 49 (01) : 76 - 85
  • [49] The Effect of Axial Wall Conduction on Heat Transfer Parameters for a Parallel-Plate Channel Having a Step Change in Boundary Conditions
    Hassab, M. A.
    Mansour, M. Khamis
    Ismail, M. Shawky
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2013, 63 (06) : 430 - 451
  • [50] Modeling of dynamic of heat exchangers in operate conditions
    Obstawski, Pawel
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (3A): : 156 - 160