Continuous Non-Invasive Blood Pressure Measurement Using 60 GHz-Radar-A Feasibility Study

被引:5
|
作者
Vysotskaya, Nastassia [1 ,2 ]
Will, Christoph [1 ]
Servadei, Lorenzo [3 ]
Maul, Noah [2 ]
Mandl, Christian [1 ]
Nau, Merlin [2 ]
Harnisch, Jens [1 ]
Maier, Andreas [2 ]
机构
[1] Infineon Technol AG, Campeon 1-15, D-85579 Neubiberg, Germany
[2] Friedrich Alexander Univ Erlangen Nuremberg FAU, Dept Comp Sci Pattern Recognit 5, Martensstr 3, D-91058 Erlangen, Germany
[3] Tech Univ Munich, Dept Elect & Comp Engn, Arcisstr 21, D-80333 Munich, Germany
关键词
FMCW radar; vital sensing; continuous blood pressure monitoring; signal processing; wearable device; PULSE-WAVE ANALYSIS; MEASURING DEVICES; TRANSIT-TIME; CALIBRATION; SOCIETY; PPG;
D O I
10.3390/s23084111
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Blood pressure monitoring is of paramount importance in the assessment of a human's cardiovascular health. The state-of-the-art method remains the usage of an upper-arm cuff sphygmomanometer. However, this device suffers from severe limitations-it only provides a static blood pressure value pair, is incapable of capturing blood pressure variations over time, is inaccurate, and causes discomfort upon use. This work presents a radar-based approach that utilizes the movement of the skin due to artery pulsation to extract pressure waves. From those waves, a set of 21 features was collected and used-together with the calibration parameters of age, gender, height, and weight-as input for a neural network-based regression model. After collecting data from 55 subjects from radar and a blood pressure reference device, we trained 126 networks to analyze the developed approach's predictive power. As a result, a very shallow network with just two hidden layers produced a systolic error of 9.2 +/- 8.3mmHg (mean error +/- standard deviation) and a diastolic error of 7.7 +/- 5.7mmHg. While the trained model did not reach the requirements of the AAMI and BHS blood pressure measuring standards, optimizing network performance was not the goal of the proposed work. Still, the approach has displayed great potential in capturing blood pressure variation with the proposed features. The presented approach therefore shows great potential to be incorporated into wearable devices for continuous blood pressure monitoring for home use or screening applications, after improving this approach even further.
引用
收藏
页数:36
相关论文
共 50 条
  • [21] CONTINUOUS NON-INVASIVE ARTERIAL PRESSURE (CNAP) MEASUREMENT: COMPARING THE CNAP DEVICE TO THE NON-INVASIVE BLOOD PRESSURE ARM CUFF DURING SURGERY
    Khera, J. K.
    Solangasenathirajan, S.
    Jones, M.
    Jonas, M.
    [J]. INTENSIVE CARE MEDICINE, 2013, 39 : S295 - S295
  • [22] A new estimate technology of non-invasive continuous blood pressure measurement based on electrocardiograph
    Wu, Chung-Min
    Chuang, Chueh Yu
    Chen, Yeou-Jiunn
    Chen, Shih-Chung
    [J]. ADVANCES IN MECHANICAL ENGINEERING, 2016, 8 (06)
  • [23] Impact of continuous, non-invasive blood pressure measurement on sleep quality during polysomnography
    Thomas Wibmer
    Benedikt Schildge
    Christoph Fischer
    Stefanie Brunner
    Cornelia Kropf-Sanchen
    Stefan Rüdiger
    Ioanna Blanta
    Kathrin M. Stoiber
    Wolfgang Rottbauer
    Christian Schumann
    [J]. Sleep and Biological Rhythms, 2013, 11 : 254 - 260
  • [24] Methods for Continuous Non-invasive Measurement of Blood Pressure: Pulse Transit Time a Review
    Kaur, Harleen
    Bhutto, Javed Khan
    Choudhary, Bhawani Shankar
    [J]. ASIAN JOURNAL OF PHARMACEUTICS, 2018, 12 (03) : S863 - S872
  • [25] Impact of continuous, non-invasive blood pressure measurement on sleep quality during polysomnography
    Wibmer, Thomas
    Schildge, Benedikt
    Fischer, Christoph
    Brunner, Stefanie
    Kropf-Sanchen, Cornelia
    Ruediger, Stefan
    Blanta, Ioanna
    Stoiber, Kathrin M.
    Rottbauer, Wolfgang
    Schumann, Christian
    [J]. SLEEP AND BIOLOGICAL RHYTHMS, 2013, 11 (04) : 254 - 260
  • [26] Non-invasive blood pressure measurement in dogs and cats
    Mandigers, P
    [J]. TIJDSCHRIFT VOOR DIERGENEESKUNDE, 2005, 130 (07) : 198 - 201
  • [27] Advances in Non-Invasive Blood Pressure Measurement Techniques
    Panula, Tuukka
    Sirkia, Jukka-Pekka
    Wong, David
    Kaisti, Matti
    [J]. IEEE REVIEWS IN BIOMEDICAL ENGINEERING, 2023, 16 : 424 - 438
  • [28] Non-invasive measurement of rapid blood pressure changes
    Raamat, R
    Toska, K
    Jagomägi, K
    Talts, J
    [J]. MEDICON 2001: PROCEEDINGS OF THE INTERNATIONAL FEDERATION FOR MEDICAL & BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2001, : 889 - 892
  • [29] Rhabdomyolysis complicating non-invasive blood pressure measurement
    Srinivasan, Chitra
    Kuppuswamy, Balaji
    [J]. INDIAN JOURNAL OF ANAESTHESIA, 2012, 56 (04) : 428 - U126
  • [30] Advances in Non-Invasive Blood Pressure Measurement Techniques
    Panula, Tuukka
    Sirkia, Jukka-Pekka
    Wong, David
    Kaisti, Matti
    [J]. IEEE REVIEWS IN BIOMEDICAL ENGINEERING, 2023, 16 : 424 - 438