Evaluation of Image Quality and Detectability of Deep Learning Image Reconstruction (DLIR) Algorithm in Single- and Dual-energy CT

被引:12
|
作者
Zhong, Jingyu [1 ]
Shen, Hailin [2 ]
Chen, Yong [3 ]
Xia, Yihan [3 ]
Shi, Xiaomeng [4 ]
Lu, Wei [5 ]
Li, Jianying [6 ]
Xing, Yue [1 ]
Hu, Yangfan [1 ]
Ge, Xiang [1 ]
Ding, Defang [1 ]
Jiang, Zhenming [1 ]
Yao, Weiwu [1 ]
机构
[1] Shanghai Jiao Tong Univ, Tongren Hosp, Dept Imaging, Sch Med, 1111 Xianxia Rd, Shanghai 200336, Peoples R China
[2] Shanghai Jiao Tong Univ, Suzhou Kowloon Hosp, Dept Radiol, Sch Med, Suzhou 215028, Peoples R China
[3] Shanghai Jiao Tong Univ, Ruijin Hosp, Sch Med, Dept Radiol, Shanghai 200025, Peoples R China
[4] Imperial Coll London, Dept Mat, South Kensington Campus, London SW7 2AZ, England
[5] GE Healthcare, Computed Tomog Res Ctr, Shanghai 201203, Peoples R China
[6] GE Healthcare, Computed Tomog Res Ctr, Beijing 100176, Peoples R China
基金
中国国家自然科学基金;
关键词
Multidetector computed tomography; Deep learning; Image reconstruction; Image enhancement; Radiation dosage; TASK-BASED PERFORMANCE; ITERATIVE RECONSTRUCTION; COMPUTED-TOMOGRAPHY; DOSE REDUCTION; ABDOMINAL CT; NOISE; CHEST; RESOLUTION; SYSTEM;
D O I
10.1007/s10278-023-00806-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study is aimed to evaluate effects of deep learning image reconstruction (DLIR) on image quality in single-energy CT (SECT) and dual-energy CT (DECT), in reference to adaptive statistical iterative reconstruction-V (ASIR-V). The Gammex 464 phantom was scanned in SECT and DECT modes at three dose levels (5, 10, and 20 mGy). Raw data were reconstructed using six algorithms: filtered back-projection (FBP), ASIR-V at 40% (AV-40) and 100% (AV-100) strength, and DLIR at low (DLIR-L), medium (DLIR-M), and high strength (DLIR-H), to generate SECT 120kVp images and DECT 120kVp-like images. Objective image quality metrics were computed, including noise power spectrum (NPS), task transfer function (TTF), and detectability index (d '). Subjective image quality evaluation, including image noise, texture, sharpness, overall quality, and low- and high-contrast detectability, was performed by six readers. DLIR-H reduced overall noise magnitudes from FBP by 55.2% in a more balanced way of low and high frequency ranges comparing to AV-40, and improved the TTF values at 50% for acrylic inserts by average percentages of 18.32%. Comparing to SECT 20 mGy AV-40 images, the DECT 10 mGy DLIR-H images showed 20.90% and 7.75% improvement in d ' for the small-object high-contrast and large-object low-contrast tasks, respectively. Subjective evaluation showed higher image quality and better detectability. At 50% of the radiation dose level, DECT with DLIR-H yields a gain in objective detectability index compared to full-dose AV-40 SECT images used in daily practice.
引用
收藏
页码:1390 / 1407
页数:18
相关论文
共 50 条
  • [41] Improved Image Quality in Dual-Energy Abdominal CT: Comparison of Iterative Reconstruction in Image Space and Filtered Back Projection Reconstruction
    Wang, Rui
    Yu, Wei
    Wu, Runze
    Yang, Hua
    Lu, Dongxu
    Liu, Jiayi
    Zhang, Zhaoqi
    Zhang, Chuanchen
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (02) : 402 - 406
  • [42] Image reconstruction and image quality evaluation for a dual source CT scanner
    Flohr, T. G.
    Bruder, H.
    Stierstorfer, K.
    Petersilka, M.
    Schmidt, B.
    McCollough, C. H.
    MEDICAL PHYSICS, 2008, 35 (12) : 5882 - 5897
  • [43] Pseudo low-energy monochromatic imaging of head and neck cancers: Deep learning image reconstruction with dual-energy CT
    Yuhei Koike
    Shingo Ohira
    Yuri Teraoka
    Ayako Matsumi
    Yasuhiro Imai
    Yuichi Akino
    Masayoshi Miyazaki
    Satoaki Nakamura
    Koji Konishi
    Noboru Tanigawa
    Kazuhiko Ogawa
    International Journal of Computer Assisted Radiology and Surgery, 2022, 17 : 1271 - 1279
  • [44] Pseudo low-energy monochromatic imaging of head and neck cancers: Deep learning image reconstruction with dual-energy CT
    Koike, Yuhei
    Ohira, Shingo
    Teraoka, Yuri
    Matsumi, Ayako
    Imai, Yasuhiro
    Akino, Yuichi
    Miyazaki, Masayoshi
    Nakamura, Satoaki
    Konishi, Koji
    Tanigawa, Noboru
    Ogawa, Kazuhiko
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2022, 17 (07) : 1271 - 1279
  • [45] Performance evaluation of a deep learning image reconstruction (DLIR) algorithm in “double low” chest CTA in children: a feasibility study
    Jihang Sun
    Haoyan Li
    Jun Gao
    Jianying Li
    Michelle Li
    Zuofu Zhou
    Yun Peng
    La radiologia medica, 2021, 126 : 1181 - 1188
  • [46] Improving lesion conspicuity in abdominal dual-energy CT with deep learning image reconstruction: a prospective study with five readers
    Jingyu Zhong
    Lingyun Wang
    Hailin Shen
    Jianying Li
    Wei Lu
    Xiaomeng Shi
    Yue Xing
    Yangfan Hu
    Xiang Ge
    Defang Ding
    Fuhua Yan
    Lianjun Du
    Weiwu Yao
    Huan Zhang
    European Radiology, 2023, 33 : 5331 - 5343
  • [47] Quantitative and qualitative assessments of deep learning image reconstruction in low-keV virtual monoenergetic dual-energy CT
    Jack Junchi Xu
    Lars Lönn
    Esben Budtz-Jørgensen
    Kristoffer L. Hansen
    Peter S. Ulriksen
    European Radiology, 2022, 32 : 7098 - 7107
  • [48] Quantitative and qualitative assessments of deep learning image reconstruction in low-keV virtual monoenergetic dual-energy CT
    Xu, Jack Junchi
    Lonn, Lars
    Budtz-Jorgensen, Esben
    Hansen, Kristoffer L.
    Ulriksen, Peter S.
    EUROPEAN RADIOLOGY, 2022, 32 (10) : 7098 - 7107
  • [49] Improving lesion conspicuity in abdominal dual-energy CT with deep learning image reconstruction: a prospective study with five readers
    Zhong, Jingyu
    Wang, Lingyun
    Shen, Hailin
    Li, Jianying
    Lu, Wei
    Shi, Xiaomeng
    Xing, Yue
    Hu, Yangfan
    Ge, Xiang
    Ding, Defang
    Yan, Fuhua
    Du, Lianjun
    Yao, Weiwu
    Zhang, Huan
    EUROPEAN RADIOLOGY, 2023, 33 (08) : 5331 - 5343
  • [50] Image quality and dose reduction opportunity of deep learning image reconstruction algorithm for CT: a phantom study
    Greffier, Joel
    Hamard, Aymeric
    Pereira, Fabricio
    Barrau, Corinne
    Pasquier, Hugo
    Beregi, Jean Paul
    Frandon, Julien
    EUROPEAN RADIOLOGY, 2020, 30 (07) : 3951 - 3959