A tunnel structure health monitoring method based on surface strain monitoring

被引:1
|
作者
Zhou, Ziyang [1 ]
Zhou, Zihan [1 ,2 ]
Lu, Chunfang [3 ]
He, Chuan [1 ]
机构
[1] Southwest Jiaotong Univ, Key Lab Transportat Tunnel Engn, Minist Educ, Chengdu 610031, Sichuan, Peoples R China
[2] Chongqing Jiaotong Univ, Inst Future Civil Engn Sci & Technol, Chongqing 400074, Peoples R China
[3] China Acad Railway Sci Corp Ltd, Beijing 100081, Peoples R China
关键词
Tunnel structure; Analytic method; Back analysis; Health monitoring; On-situ experiment; DEFORMATION;
D O I
10.1007/s13349-024-00788-8
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The effectiveness of tunnel monitoring is a challenging task due to the limitations of monitoring gauges and lack of monitoring sections. To address this, a novel theoretical analysis-based monitoring method for tunnel structures was proposed in this study. A theoretical approach was employed to establish the correlation between external loads and structural stress-strain response in tunnel lining during grouting and stability periods. A method has been developed to derive the distribution of external loads and internal forces throughout the entire tunnel using strain monitoring at specific locations on the structure. This method has been further validated through a case study of the Liucun Tunnel, providing insights into the accuracy of the monitoring approach. It is found that during the grouting period, the segment ring is surrounded by grout, resulting in peak external loads and internal forces. As the tunnel lining enters the load stability period, both the external loads and internal forces gradually decrease and stabilize. Comparing the results of the monitored method for deriving tunnel external loads, structural bending moments and axial forces with the on-situ measurements, the new monitoring method yields errors in the response of tunnel external loads and internal forces. The average error in external loads is less than 12%, the average error in bending moments is less than 20%, and the average error in axial forces is less than 8%. The proposed monitoring method effectively addresses the issue of long-term failure of monitoring elements due to its replaceability. Additionally, utilizing theoretical methods for derivation allows obtaining more tunnel structural information based on limited monitoring data from the elements. This provides a new approach for long-term structural health monitoring. To address the existing errors in the monitoring method described in this study, the accuracy can be further improved by optimizing the model, incorporating more advanced monitoring techniques, and implementing standardized and improved construction practices.
引用
收藏
页码:1339 / 1367
页数:29
相关论文
共 50 条
  • [21] Monitoring technology and method of karst surface and structure deformation based on radar interferometry
    Hu, Jiyuan
    Cehui Xuebao/Acta Geodaetica et Cartographica Sinica, 2022, 51 (10):
  • [22] On a defect identification method based on monitoring the structure and peculiarities of surface wave fields
    O. V. Bocharova
    A. V. Sedov
    I. E. Andzhikovich
    V. V. Kalinchuk
    Russian Journal of Nondestructive Testing, 2016, 52 : 377 - 382
  • [23] Telecommunications tunnel monitoring system based on distributed optical fiber strain measurement
    Naruse, H
    Komatsu, K
    Fujihashi, K
    Okutsu, M
    17TH INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS, PTS 1 AND 2, 2005, 5855 : 168 - 171
  • [24] A comprehensive virtual reality system for tunnel surface documentation and structural health monitoring
    Attard, Leanne
    Debono, Carl James
    Valentino, Gianluca
    di Castro, Mario
    Osborne, John Andrew
    Scibile, Luigi
    Ferre, Manuel
    2018 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS AND TECHNIQUES (IST), 2018, : 158 - 163
  • [25] Optical fibre strain measurement for tunnel lining monitoring
    Cheung, L. L. K.
    Soga, K.
    Bennett, P. J.
    Kobayashi, Y.
    Amatya, B.
    Wright, P.
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-GEOTECHNICAL ENGINEERING, 2010, 163 (03) : 119 - 130
  • [26] Structural Health Monitoring Method of Pantograph-Catenary System Based on Strain Response Inversion
    Liu, Sheng
    Wei, Yibo
    Yin, Yongxin
    Feng, Tangzheng
    Lin, Jinbao
    FRONTIERS IN PHYSICS, 2021, 9
  • [27] Electrospun Nanofiber Based Strain Sensors for Structural Health Monitoring
    Servati, P.
    Soltanian, S.
    Ko, F.
    STRUCTURAL HEALTH MONITORING 2013, VOLS 1 AND 2, 2013, : 1535 - 1542
  • [28] Strain based structural health monitoring of stiffened composite plate
    Chandra Sahoo P.
    Nimje S.V.
    Roy S.
    Materials Today: Proceedings, 2023, 72 : 1631 - 1636
  • [29] Study of sensitivity for strain-based structural health monitoring
    Herrera-Iriarte, A.
    Alvarez-Montoya, J.
    Sierra-Perez, J.
    4TH INTERNATIONAL CONFERENCE ON RELIABILITY ENGINEERING (ICRE 2019), 2020, 836
  • [30] MEMS based strain and corrosion sensors for Structural Health Monitoring
    Mugambi, E. M.
    Kwan, K.
    Laskowski, B. C.
    Ooi, T. K.
    Corder, A.
    STRUCTURAL HEALTH MONITORING 2007: QUANTIFICATION, VALIDATION, AND IMPLEMENTATION, VOLS 1 AND 2, 2007, : 730 - 737