Electrochemical biosensor for highly sensitive detection of cTnI based on a dual signal amplification strategy of ARGET ATRP and ROP

被引:9
|
作者
Gao, Tianyu [1 ]
Zhou, Zhenbo [2 ]
Cheng, Di [2 ]
Liu, Yanju [2 ]
Yang, Huaixia [2 ]
Wang, Ying [3 ]
机构
[1] Henan Univ Tradit Chinese Med, Affiliated Hosp 1, Zhengzhou, Peoples R China
[2] Henan Univ Chinese Med, Pharm Coll, Zhengzhou 450046, Peoples R China
[3] Zhengzhou Univ, Dept Geriatr Endocrinol, Affiliated Hosp 1, Zhengzhou 450052, Peoples R China
关键词
Biosensor; CTnI; Dual signal amplification; ARGET ATRP; ROP; CARDIAC TROPONIN-I; RADICAL POLYMERIZATION; APTASENSOR;
D O I
10.1016/j.talanta.2023.125009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cardiac troponin I (cTnI), a gold biomarker for the diagnosis of acute myocardial infarction (AMI), plays a vital role in the early diagnosis, treatment and prognosis analysis of AMI. In this paper, an electrochemical biosensor for the highly sensitive determination of cTnI was fabricated based on the dual signal amplification strategy of electron transfer atom transfer radical polymerization (ARGET ATRP) and ring-opening polymerization (ROP) for the first time. Briefly, the thiolate cTnI-aptamer 1, which was bonded to the electrode via Au-S bonds, specifically captured cTnI to the electrode surface. Then, cTnI-aptamer 2 (Apt2) was successfully introduced to the electrode surface to form Apt-cTnI-Apt sandwich structure. Subsequently, the initiator BIBB was connected to Apt2 through bromination reaction, and then the resulting ATRP polymer was employed as a macromolecular initiator for the succeeding reaction. Next, the monomers, & alpha;-amino acid-N-carboxylic acid anhydride ferrocene derivatives (NCA-Fc), used for the ROP reaction produced numerous electroactive polymers on the electrode surface. The dual action of ARGET ATRP and ROP significantly improved sensitivity of cTnI biosensor assay, the prepared biosensor displayed a wide linear detection range from 100 fg mL-1 to 100 ng mL-1, with a detection limit of 32.24 fg mL-1. The method exhibited favorable selectivity, simple operation and excellent stability. Furthermore, the biosensor still rendered satisfactory analytical performance in the detection of clinical serum samples, indicating the application potential in clinical diagnosis.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Simple Enzyme-Free Biosensor for Highly Sensitive and Selective Detection of miR-21 Based on Multiple Signal Amplification Strategy
    Huang, Lin-Na
    Zhong, Zi-Jie
    Lu, Qiu-Jun
    Chen, Feng
    Xie, Ling-Ling
    Wu, Cui-Yan
    Zhang, You-Yu
    JOURNAL OF ANALYSIS AND TESTING, 2022, 6 (01) : 36 - 43
  • [42] Simple Enzyme-Free Biosensor for Highly Sensitive and Selective Detection of miR-21 Based on Multiple Signal Amplification Strategy
    Lin-Na Huang
    Zi-Jie Zhong
    Qiu-Jun Lu
    Feng Chen
    Ling-Ling Xie
    Cui-Yan Wu
    You-Yu Zhang
    Journal of Analysis and Testing, 2022, 6 : 36 - 43
  • [43] Simple Enzyme-Free Biosensor for Highly Sensitive and Selective Detection of miR-21 Based on Multiple Signal Amplification Strategy
    Lin-Na Huang
    Zi-Jie Zhong
    Qiu-Jun Lu
    Feng Chen
    Ling-Ling Xie
    Cui-Yan Wu
    You-Yu Zhang
    JournalofAnalysisandTesting, 2022, 6 (01) : 36 - 43
  • [44] Highly sensitive biosensor for specific miRNA detection based on cascade signal amplification and magnetic electrochemiluminescence nanoparticles
    Li, Jiawen
    Chen, Cheng
    Luo, Fang
    Lin, Zhenyu
    Wang, Jian
    Huang, Aiwen
    Sun, Ying
    Qiu, Bin
    ANALYTICA CHIMICA ACTA, 2024, 1288
  • [45] Electrochemical biosensor for detection of ampicillin in milk based on Au5Pt and DNA cycle dual-signal amplification strategy
    Li, Mingyao
    Li, Ruiyi
    Li, Zaijun
    MICROCHIMICA ACTA, 2025, 192 (01)
  • [46] Dual-Signal Amplification Strategy for Sensitive MicroRNA Detection Based on Rolling Circle Amplification and Enzymatic Repairing Amplification
    Xiao, Fubing
    Liu, Jie
    Guo, Qinghui
    Du, Zhibo
    Li, Hong
    Sun, Chunlong
    Du, Wenfang
    ACS OMEGA, 2020, 5 (50): : 32738 - 32743
  • [47] A sensitive determination of albumin in urine by molecularly imprinted electrochemical biosensor based on dual-signal strategy
    Zhang, Guihua
    Yu, Ying
    Guo, Manli
    Lin, Bixia
    Zhang, Li
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 288 : 564 - 570
  • [48] Highly sensitive biosensor based on target induced dual signal amplification to electrochemiluminescent nanoneedles of Ru(II) complex
    Wang, Haijun
    Song, Yuhang
    Chai, Yaqin
    Yuan, Ruo
    BIOSENSORS & BIOELECTRONICS, 2019, 140 : 64 - 68
  • [49] Dual signal amplification photoelectrochemical biosensor for highly sensitive human epidermal growth factor receptor-2 detection
    Guo, Xiaoxi
    Liu, Shuping
    Yang, Minghui
    Du, Huitong
    Qu, Fengli
    BIOSENSORS & BIOELECTRONICS, 2019, 139
  • [50] DSN signal amplification strategy based nanochannels biosensor for the detection of miRNAs
    Liao, Tang-Bin
    Luo, Ke-Xin
    Tu, Ji-Yuan
    Zhang, Yu-Lin
    Zhang, Guo-Jun
    Sun, Zhong-Yue
    BIOELECTROCHEMISTRY, 2024, 160