Novel Hotspot Temperature Prediction of Oil-Immersed Distribution Transformers: An Experimental Case Study

被引:11
|
作者
Abdali, Ali [1 ,2 ]
Abedi, Ali [1 ]
Mazlumi, Kazem [3 ]
Rabiee, Abbas [3 ]
Guerrero, Josep M. [4 ]
机构
[1] Kooshkan Transformers Co, R&D Dept, Zanjan 1991647113, Iran
[2] Univ Zanjan, Fac Engn, Dept Elect Engn, Zanjan 4537138791, Iran
[3] Univ Zanjan, Fac Engn, Dept Elec tr Engn, Zanjan 4537138791, Iran
[4] Aalborg Univ, CROM Ctr Res Microgrids, AAU Energy, DK-9220 Aalborg, Denmark
关键词
Oil insulation; Mathematical models; Power transformer insulation; Windings; Transformers; Oils; IEC Standards; Computational fluid dynamics (CFD); corrugated wall distribution transformer (DT); hotspot temperature (HST); optical fiber sensor (OFS); thermal camera; HOT-SPOT TEMPERATURE; POWER TRANSFORMER; MODEL; OPTIMIZATION; MANAGEMENT;
D O I
10.1109/TIE.2022.3206690
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Distribution transformers (DTs) are deemed fundamental and high-priced equipment for power grids, and their failure influences grid reliability. The continuity of DT operation highly depends on its insulation conditions and following that to the hotspot temperature (HST). In this article, a novel formula is proposed for HST prediction of DTs by considering the effective electrical and mechanical parameters on heat dissipation capacity. Additionally, complete and accurate 3D modeling based on computational fluid dynamics (CFD) is presented to validate the proposed novel formula for HST prediction. In this modeling, the conservator, which plays a key role in the HST value, is accurately modeled. Optical fiber sensors are utilized in the studied 500-kVA DT to verify the accuracy of the proposed HST prediction formula during the experimental temperature rise test. Experimental results show that the proposed formula is highly accurate and has an acceptable correlation with the empirical values. The root-mean-square error, mean error, and average error percentage (AEP) of the proposed formula are 0.3?, 0.3 ?, and 0.37%, respectively, in HST transient values, and 0.3 ?, 0.3 ?, and 0.29% in HST steady-state values, which substantiate the precision and proficiency of the proposed HST prediction formula rather than IEC and IEEE equations. Finally, a thermal camera is employed to verify the results of CFD-based 3D modeling in top-oil temperature, bottom-oil temperature, and conservator oil temperature during the experimental tests. According to the measurement results, temperatures of CFD-based 3D simulation and thermal camera in the aforementioned three points are in good agreement with each other and AEP is less than 1.4%, which indicates the accuracy and efficiency of the proposed 3-D modeling.
引用
收藏
页码:7310 / 7322
页数:13
相关论文
共 50 条
  • [21] Experimental and numerical investigation of wicked heat pipe cooling efficacy in oil-immersed transformers
    Dastjerd, Fateme Tavakoli
    Niazmand, Hamid
    Mahian, Omid
    APPLIED THERMAL ENGINEERING, 2024, 250
  • [22] 3D modeling of winding hot spot temperature in oil-immersed transformers
    Reza Kebriti
    S. M. Hassan Hossieni
    Electrical Engineering, 2022, 104 : 3325 - 3338
  • [23] The Study and Analysis of Oil-immersed Power Transformer by Using Artificial Neural Network for Designing Program Apply in the Industry of Testing Oil-immersed Transformers
    Boonsaner, Nutthaphan
    Chancharoensook, Phop
    Bunnag, Chisanucha
    Suwantaweesuk, Achirawit
    Vongphanich, Kiattisak
    2020 8TH INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD 2020), 2020, : 274 - 277
  • [24] 3D modeling of winding hot spot temperature in oil-immersed transformers
    Kebriti, Reza
    Hossieni, S. M. Hassan
    ELECTRICAL ENGINEERING, 2022, 104 (05) : 3325 - 3338
  • [25] Recent diagnostic technology on oil-immersed power transformers in Japan
    Tsuchie, M
    IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS: NEW WAVE OF T&D TECHNOLOGY FROM ASIA PACIFIC, 2002, : 1496 - 1499
  • [26] Ensemble Anomaly Data Detection Method for Oil-immersed Transformers
    Kari, Tusongjiang
    Abudukerimu, Munawaer
    Jia, Jing
    Ma, Xiaojing
    2024 6TH ASIA ENERGY AND ELECTRICAL ENGINEERING SYMPOSIUM, AEEES 2024, 2024, : 463 - 468
  • [27] On the estimation.of elapsed life of oil-immersed power transformers
    Pradhan, MK
    Ramu, TS
    IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (03) : 1962 - 1969
  • [28] Effect of loads on temperature distribution characteristics of oil-immersed transformer winding
    Zhao Z.
    Jiang Z.
    Li Y.
    Li C.
    Zhang D.
    Distributed Generation and Alternative Energy Journal, 2022, 37 (02): : 237 - 254
  • [29] A Probabilistic Approach for Forecasting the Allowable Current of Oil-Immersed Transformers
    Bracale, Antonio
    Carpinelli, Guido
    Pagano, Mario
    De Falco, Pasquale
    IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (04) : 1825 - 1834
  • [30] The Aging Diagnosis of Solid Insulation for Oil-Immersed Power Transformers and Its Remaining Life Prediction
    Lin Chaohui
    Zhang Bide
    Yuan Yuchun
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,