SSO risk evaluation method for grid-connected wind farm systems based on LHS and extended Prony

被引:0
|
作者
Chen, Wei [1 ]
Liu, Zhaohui [1 ]
Wei, Zhanhong [1 ]
Shi, Jinhui [1 ]
Xun, Ziang [1 ]
机构
[1] Lanzhou Univ Technol, Coll Elect & Informat Engn, Lanzhou 730050, Peoples R China
基金
中国国家自然科学基金;
关键词
DFIG-based wind farm; Subsynchronous oscillation; Extended Prony; LHS; Risk evaluation; STABILITY ANALYSIS; DAMPING CONTROL;
D O I
10.1007/s00202-022-01702-5
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As the proportion of installed wind power is increasing every year, the dynamic characteristics of the grid-connected system for wind farms are increasingly becoming complex, and the system faces the risk of subsynchronous oscillation (SSO). The uncertainty of wind speed and series compensation degree has significant effects on the SSO of the series-compensated grid-connected system of doubly-fed induction generator (DFIG)-based wind farms. The oscillation risk of the grid-connected wind power systems is highly stochastic and time-varying and is difficult to evaluate accurately and quantitatively. Given the above problems, this paper proposes a risk evaluation method for SSO of the grid-connected system for series-compensated DFIG-based wind farms considering the uncertainty of wind speed and series compensation degree. First, the mechanism and time-varying characteristics of the subsynchronous oscillation of the grid-connected wind power systems are analyzed, and the risk quantification index is accordingly selected. Secondly, according to the oscillation analysis model of the doubly-fed wind farm grid-connected system, the extended Prony and Latin hypercube sampling are used to identify the SSO signal, and the least-squares polynomial method is applied to obtain the indicator model for the corresponding mode. Then, the risk matrix is used to quantify the probability and severity of the occurrence of subsynchronous oscillation risk caused by the uncertainty of the grid-connected wind farm systems. Finally, examples are presented to verify the effectiveness and viability of the proposed method.
引用
收藏
页码:853 / 865
页数:13
相关论文
共 50 条
  • [1] SSO risk evaluation method for grid-connected wind farm systems based on LHS and extended Prony
    Wei Chen
    Zhaohui Liu
    Zhanhong Wei
    Jinhui Shi
    Ziang Xun
    Electrical Engineering, 2023, 105 : 853 - 865
  • [2] SSO Risk Evaluation for a Grid-connected PMSG-based Wind Farm Based on Sequential Monte Carlo Simulation
    Tao, Shun
    Liu, Yunbo
    Yan, Yanan
    Zhao, Lei
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2023, 9 (04): : 1348 - 1358
  • [3] A novel dynamic equivalence method for grid-connected wind farm
    Jia-geng Qiao
    Zong-xiang Lu
    Yong Min
    Journal of Zhejiang University-SCIENCE A, 2008, 9 : 558 - 563
  • [4] A simulation method of grid-connected wind farm on transient stability
    Han, Xiaoning
    Lei, Qiaohong
    Shi, Yan
    Han, Xiaoqing
    2007 CONFERENCE PROCEEDINGS IPEC, VOLS 1-3, 2007, : 955 - +
  • [6] A novel dynamic equivalence method for grid-connected wind farm
    Qiao, Jia-Geng
    Lu, Zong-Xiang
    Min, Yong
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2008, 9 (04): : 558 - 563
  • [7] Supervision of a Grid-Connected Wind Farm by the Electric Production Distribution Method
    Amor, Walid Ouled
    Ghariani, Moez
    Guesmi, Soltana
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2015, 5 (04): : 944 - 951
  • [8] Analysis of SSO Influencing Factors and Parameter Adjustment for Grid-Connected Full-Converter Wind Farm Based on Impedance Sensitivity
    Zhang M.
    Xiao S.
    Tian T.
    Zhang H.
    Bi T.
    Liang F.
    Dianwang Jishu/Power System Technology, 2018, 42 (09): : 2768 - 2777
  • [9] Overview of Subsynchronous Oscillation in Grid-connected Wind Farm
    Xu Pei-Zhen
    Lu Yong-Geng
    Cao Xi-Min
    RECENT ADVANCES IN ELECTRICAL & ELECTRONIC ENGINEERING, 2020, 13 (07) : 969 - 979
  • [10] Grid-connected Multilevel Topology for HVDC Offshore Wind Farm Based on MFT
    Firas Obeidat
    XU Lie
    LI Yong-dong
    电力电子技术, 2013, 47 (06) : 29 - 32