Fault location for general AC/DC transmission lines: Multi-phase, non-homogeneous, partially mutually coupled and multi-terminal lines

被引:4
|
作者
Lu, Dayou [1 ]
Liu, Yu [1 ,2 ]
机构
[1] ShanghaiTech Univ, Sch Informat Sci & Technol, Shanghai 201210, Peoples R China
[2] Minist Educ, Key Lab Control Power Transmiss & Convers SJTU, Shanghai 200240, Peoples R China
基金
中国国家自然科学基金;
关键词
Fault location; Multi-phase line; Non-homogeneous line; Partially mutually coupled line; Multi-terminal line; Time domain; Distributed parameter; Partial differential equations (PDEs); ALGORITHM; SCHEME; SYSTEM;
D O I
10.1016/j.epsr.2023.109484
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The complexity of a general AC/DC transmission line is mainly caused by the components such as multi-phase line, non-homogeneous line, partially mutually coupled line and multi-terminal line. This paper proposes a systematic methodology to accurately locate faults in a general complex AC/DC transmission line. Instantaneous measurements only at line terminals are required. First, the modeling methodologies of symmetrical/asym-metrical multi-phase line, non-homogeneous (including partially mutually coupled) line and multi-terminal line are proposed. The distributed parameter line model is fully considered with partial differential equations (PDEs) in time domain. Second, the voltage distribution along the entire line is obtained via numerical solutions. Third, the faulted segment and fault location is determined based on the calculated voltage distribution. The proposed method is carefully designed to ensure applicability for a general AC/DC transmission line, independent of the numbers of phases/poles, non-homogeneous (including partially mutually coupled) sections, terminals, and joint points. Numerical experiments in two example complex transmission lines prove that the proposed method can accurately identify faulted segments and locate faults under different fault conditions. The method works with a relatively low sampling rate of 20k samples/sec and a data window of 5 ms after the fault occurs.
引用
收藏
页数:11
相关论文
共 41 条
  • [31] A Novel Protection Based on Current Correlation for DC Lines in Hybrid Cascaded Multi-Terminal HVDC Transmission System
    Liu, Ningning
    Li, Yongli
    Chen, Xiaolong
    Li, Song
    Li, Tao
    IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (04) : 2794 - 2809
  • [32] Travelling wave fault location principle for hybrid multi-terminal LCC-MMC-HVDC transmission lines based on C-EVT
    Wang, Dong
    Yang, Haishan
    Hou, Mengqian
    Guo, Yifei
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 185
  • [33] A non-contact current traveling wave fault location method for multi-terminal overhead power lines based on adaptive mathematical morphology
    Ayambire, Patrick N.
    Huang, Qi
    Awopone, Albert K.
    Jian, Li
    Anane, Paul O. K.
    Bamisile, Olusola
    Zhang, Zhenyuan
    ELECTRICAL ENGINEERING, 2024, : 191 - 204
  • [34] A Novel Single-Terminal Fault Location Method for AC Transmission Lines in a MMC-HVDC-Based AC/DC Hybrid System
    Xue, Shimin
    Lu, Junchi
    Liu, Chong
    Sun, Yabing
    Liu, Baibing
    Gu, Cheng
    ENERGIES, 2018, 11 (08):
  • [35] A pilot protection based on Zero-Sequence voltage ratio for AC lines in hybrid Multi-Terminal HVDC transmission system
    Liu, Ningning
    Li, Yongli
    Chen, Xiaolong
    Li, Song
    Li, Tao
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 155
  • [36] Single-ended Protection Scheme for Hybrid Multi-terminal DC Transmission Lines Based on Intrinsic Mode Feature Vector
    Dai, Zhihui
    Xi, Xiaorui
    Li, Tiecheng
    Niu, Baoyi
    Li, Hangze
    Gaodianya Jishu/High Voltage Engineering, 2024, 50 (10): : 4627 - 4639
  • [37] TLBO merged with studying effect for Economic Environmental Energy Management in High Voltage AC Networks Hybridized with Multi-Terminal DC Lines
    Sarhan, Shahenda
    El-Sehiemy, Ragab A.
    Shaheen, Abdullah M.
    Gafar, Mona
    APPLIED SOFT COMPUTING, 2023, 143
  • [38] Single-ended Protection Scheme for Multi-terminal Hybrid DC Lines Based on Initial Current Traveling Wave Phase
    Dai Z.
    Niu B.
    Qiu H.
    Xi X.
    Han Z.
    Wei S.
    Gaodianya Jishu/High Voltage Engineering, 2024, 50 (02): : 649 - 659
  • [39] A Model-Based DC Fault Location Scheme for Multi-Terminal MMC-HVDC Systems Using a Simplified Transmission Line Representation
    Xu, Jianzhong
    Lu, Yu
    Zhao, Chengyong
    Liang, Jun
    IEEE TRANSACTIONS ON POWER DELIVERY, 2020, 35 (01) : 386 - 395
  • [40] Non-contact fault location and identification method for same-tower multi-circuit transmission lines
    Yin, Tao
    Li, Jian
    Cai, Dongsheng
    Huang, Qi
    Hu, Weihao
    ENERGY REPORTS, 2021, 7 : 147 - 158