Markerless head motion tracking and event-by-event correction in brain PET

被引:6
|
作者
Zeng, Tianyi [1 ]
Lu, Yihuan [1 ,2 ]
Jiang, Weize [2 ]
Zheng, Jiaxu [2 ]
Zhang, Jiazhen [1 ]
Gravel, Paul [1 ]
Wan, Qianqian [2 ]
Fontaine, Kathryn [1 ]
Mulnix, Tim [1 ]
Jiang, Yulin [2 ]
Yang, Zhaohui [2 ]
Revilla, Enette Mae [1 ]
Naganawa, Mika [1 ]
Toyonaga, Takuya [1 ]
Henry, Shannan [1 ]
Zhang, Xinyue [2 ]
Cao, Tuoyu [2 ]
Hu, Lingzhi [2 ]
Carson, Richard E. [1 ]
机构
[1] Yale Univ, Dept Radiol & Biomed Imaging, New Haven, CT 06520 USA
[2] United Imaging Healthcare, Houston, TX USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2023年 / 68卷 / 24期
关键词
markerless motion tracking system; PET; head motion; event-by-event correction; registration quality metric; 1ST-IN-HUMAN; REGISTRATION; MCT;
D O I
10.1088/1361-6560/ad0e37
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Head motion correction (MC) is an essential process in brain positron emission tomography (PET) imaging. We have used the Polaris Vicra, an optical hardware-based motion tracking (HMT) device, for PET head MC. However, this requires attachment of a marker to the subject's head. Markerless HMT (MLMT) methods are more convenient for clinical translation than HMT with external markers. In this study, we validated the United Imaging Healthcare motion tracking (UMT) MLMT system using phantom and human point source studies, and tested its effectiveness on eight 18F-FPEB and four 11C-LSN3172176 human studies, with frame-based region of interest (ROI) analysis. We also proposed an evaluation metric, registration quality (RQ), and compared it to a data-driven evaluation method, motion-corrected centroid-of-distribution (MCCOD). Approach. UMT utilized a stereovision camera with infrared structured light to capture the subject's real-time 3D facial surface. Each point cloud, acquired at up to 30 Hz, was registered to the reference cloud using a rigid-body iterative closest point registration algorithm. Main results. In the phantom point source study, UMT exhibited superior reconstruction results than the Vicra with higher spatial resolution (0.35 +/- 0.27 mm) and smaller residual displacements (0.12 +/- 0.10 mm). In the human point source study, UMT achieved comparable performance as Vicra on spatial resolution with lower noise. Moreover, UMT achieved comparable ROI values as Vicra for all the human studies, with negligible mean standard uptake value differences, while no MC results showed significant negative bias. The RQ evaluation metric demonstrated the effectiveness of UMT and yielded comparable results to MCCOD. Significance. We performed an initial validation of a commercial MLMT system against the Vicra. Generally, UMT achieved comparable motion-tracking results in all studies and the effectiveness of UMT-based MC was demonstrated.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Evaluation of electromagnetic motion tracking and event-by-event motion correction in clinical brain PET imaging
    Tan, Wanbin
    Wang, Zipai
    Zeng, Xinjie
    Li, Yixin
    Chiang, Gloria
    Li, Yi
    de Leon, Mony
    Ajay, Gupta
    Goldan, Amirhossein
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [2] Data-driven motion detection and event-by-event correction for brain PET
    Lu, Yihuan
    Gallezot, Jean-Dominique
    Naganawa, Mika
    Fontaine, Kathryn
    Toyonaga, Takuya
    Ren, Silin
    Mulnix, Tim
    Liu, Chi
    Carson, Richard
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [3] Data-Driven Motion Detection and Event-by-Event Correction for Brain PET: Comparison with Vicra
    Lu, Yihuan
    Naganawa, Mika
    Toyonaga, Takuya
    Gallezot, Jean-Dominique
    Fontaine, Kathryn
    Ren, Silin
    Revilla, Enette Mae
    Mulnix, Tim
    Carson, Richard E.
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61 (09) : 1397 - 1403
  • [4] Event-by-Event Continuous Respiratory Motion Correction for Dynamic PET Imaging
    Yu, Yunhan
    Chan, Chung
    Ma, Tianyu
    Liu, Yaqiang
    Gallezot, Jean-Dominique
    Naganawa, Mika
    Kelada, Olivia J.
    Germino, Mary
    Sinusas, Albert J.
    Carson, Richard E.
    Liu, Chi
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (07) : 1084 - 1090
  • [5] Event-by-event motion compensation for small animal PET
    Zhou, Victor W.
    Kyme, Andre Z.
    Meikle, Steven R.
    Fulton, Roger R.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3109 - +
  • [6] Evaluation of Frame-Based and Event-by-Event Motion-Correction Methods for Awake Monkey Brain PET Imaging
    Jin, Xiao
    Mulnix, Tim
    Sandiego, Christine M.
    Carson, Richard E.
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (02) : 287 - 293
  • [7] Event-by-event motion compensation in 3D PET
    Fulton, R
    Nickel, I
    Tellmann, L
    Meikle, S
    Pietrzyk, U
    Herzog, H
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3286 - 3289
  • [8] Event-by-event Respiratory Motion Correction for PET with 3-Dimensional Internal-external Motion Correlation
    Chan, Chung
    Jin, Xiao
    Fung, Edward K.
    Naganawa, Mika
    Mulnix, Tim
    Carson, Richard E.
    Liu, Chi
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2117 - 2122
  • [9] Direct reconstruction of parametric images for brain PET with event-by-event motion correction: evaluation in two tracers across count levels
    Germino, Mary
    Gallezot, Jean-Dominque
    Yan, Jianhua
    Carson, Richard E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (13): : 5344 - 5364
  • [10] Assessment of a new PET event-by-event image-based motion correction for brain imaging in amyloid and epilepsy on a multimodality PET-MR scanner
    Rodriguez, J. Anton
    Herholz, K.
    Oldfield, C.
    Spangler-Bickell, M. G.
    Deller, T. W.
    Parkes, L. M.
    Matthews, J. C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S716 - S717