Dual-Energy CT for Detecting Painful Knee Prosthesis Loosening

被引:8
|
作者
Foti, Giovanni [1 ]
Longo, Chiara [1 ]
D'Onofrio, Mirko [3 ]
Natali, Simone [2 ]
Piovan, Gianluca [2 ]
Oliboni, Eugenio [1 ]
Iacono, Venanzio [2 ]
Guerriero, Massimo [4 ]
Zorzi, Claudio [2 ]
机构
[1] IRCCS Sacro Cuore Don Calabria Hosp, Dept Radiol, Via Don A Sempreboni 10, I-37024 Negrar, Italy
[2] IRCCS Sacro Cuore Don Calabria Hosp, Dept Orthopaed Surg, Via Don A Sempreboni 10, I-37024 Negrar, Italy
[3] Verona Univ Hosp, Dept Radiol, Verona, Italy
[4] Univ Verona, Dept Comp Sci, Verona, Italy
关键词
UNITED-STATES; ARTIFACTS; HIP; ARTHROPLASTY; REPLACEMENT; REDUCTION; QUALITY;
D O I
10.1148/radiol.211818
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Dual-energy CT (DECT) is an alternative to radiography and single-energy CT (SECT) for detecting prosthesis -related complications. Purpose: To compare the diagnostic performance of DECT, SECT, and radiography for knee prosthesis loosening, with use of surgery or imaging follow-up reference standards. Materials and Methods: In this prospective single-center study from December 2018 to June 2021, participants with unilateral painful knee prostheses underwent radiographic, SECT, and DECT imaging. Five blinded readers, four radiologists, and one orthopedic surgeon evaluated the images. Prosthesis loosening was diagnosed by a periprosthetic lucent zone greater than 2 mm. The sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) of each method were determined and compared with use of a multireader multicase analysis. Results: There were 92 study participants (mean age +/- SD, 70 years +/- 9.4; 67 women) evaluated. Tibial and femoral loosening were diagnosed in 47 and 24 participants, respectively. For the tibia, mean sensitivity and specificity for arthroplasty loosening were 88% and 91%, respectively, for DECT, 73% and 78% for SECT, and 68% and 81% for radiography. For the tibia, DECT demonstrated similar diagnostic performance (AUC, 0.90) to SECT (AUC: 0.90 vs AUC: 0.87, respectively; P = .13) but was superior to radiog-raphy (AUC: 0.90 vs AUC: 0.82; P = .002). Overall diagnostic performance of DECT (AUC, 0.87) for the femur was superior to both SECT and radiography (P < .001). Conclusion: Dual-energy CT had generally better diagnostic performance in detecting loosening of tibial and femoral components after total knee arthroplasty compared with single-energy CT or radiography.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Dual-Energy CT of Gallstone Ileus
    Liu, Peng
    Tan, Xian-zheng
    RADIOLOGY, 2020, 295 (03) : 516 - 516
  • [22] Dual-Energy CT: Oncologic Applications
    De Cecco, Carlo Nicola
    Darnell, Anna
    Rengo, Marco
    Muscogiuri, Giuseppe
    Bellini, Davide
    Ayuso, Carmen
    Laghi, Andrea
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : S98 - S105
  • [23] Clinical Applications of Dual-Energy CT
    Hamid, Saira
    Nasir, Muhammad Umer
    So, Aaron
    Andrews, Gordon
    Nicolaou, Savvas
    Qamar, Sadia Raheez
    KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (06) : 970 - 982
  • [24] Dual-Energy CT Applications in the Abdomen
    Heye, Tobias
    Nelson, Rendon C.
    Ho, Lisa M.
    Marin, Daniele
    Boll, Daniel T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : S64 - S70
  • [25] Dual-Energy CT Principles and Applications
    Chellini, David
    Kinman, Karen
    RADIOLOGIC TECHNOLOGY, 2020, 91 (06) : 561CT - 576CT
  • [26] Dual-energy CT in musculoskeletal trauma
    Wong, A. J. N.
    Wong, M.
    Kutschera, P.
    Lau, K. K.
    CLINICAL RADIOLOGY, 2021, 76 (01) : 38 - 49
  • [27] Dual-Energy CT in the Acute Abdomen
    Uyeda J.W.
    Patino M.
    Sahani D.V.
    Current Radiology Reports, 3 (6)
  • [28] Dual-energy CT of the urinary tract
    Kaza, Ravi K.
    Platt, Joel F.
    Megibow, Alec J.
    ABDOMINAL IMAGING, 2013, 38 (01): : 167 - 179
  • [29] Dual-Energy CT: General Principles
    Johnson, Thorsten R. C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : S3 - S8
  • [30] Dual-Energy CT for the Musculoskeletal System
    Mallinson, Paul I.
    Coupal, Tyler M.
    McLaughlin, Patrick D.
    Nicolaou, Savvas
    Munk, Peter L.
    Ouellette, Hugue A.
    RADIOLOGY, 2016, 281 (03) : 690 - 707