Performance of TES X-Ray Microcalorimeters Designed for 14.4-keV Solar Axion Search

被引:1
|
作者
Yagi, Y. [1 ,3 ]
Konno, R. [1 ,4 ]
Hayashi, T. [2 ]
Tanaka, K. [1 ,3 ]
Yamasaki, N. Y. [1 ,3 ,4 ]
Mitsuda, K. [5 ]
Sato, R. [6 ]
Saito, M. [7 ]
Homma, T. [6 ,7 ]
Nishida, Y. [8 ]
Mori, S. [8 ]
Iyomoto, N. [8 ]
Hara, T. [9 ]
机构
[1] Japan Aerosp Explorat Agcy JAXA, Dept Space Astron & Astrophys, Inst Space & Astronaut Sci ISAS, 3-1-1 Yoshinodai,Chuo Ku, Sagamihara, Kanagawa 2525210, Japan
[2] Japan Aerosp Explorat Agcy JAXA, Inst Space & Astronaut Sci ISAS, Astromat Sci Res Grp ASRG, 3-1-1 Yoshinodai,Chuo Ku, Sagamihara, Kanagawa 2525210, Japan
[3] Univ Tokyo, Sch Sci, Dept Phys, 7-3-1 Hongo,Bunkyo Ku, Tokyo 1130033, Japan
[4] Kitasato Univ, Sch Sci, Dept Phys, 1-15-1 Kitasato,Minami Ku, Sagamihara, Kanagawa 2520373, Japan
[5] Natl Astron Observ Japan NAOJ, 2-21-1 Osawa, Mitaka, Tokyo 1818588, Japan
[6] Waseda Univ, Sch Adv Sci & Engn, Dept Appl Chem, Okubo 3-4-1,Shinjuku Ku, Tokyo 1698555, Japan
[7] Waseda Univ, Res Org Nano & Life Innovat, 513 Waseda Tsurumaki Cho,Shinjuku Ku, Tokyo 1620041, Japan
[8] Kyushu Univ, Dept Appl Quantum Phys & Nucl Engn, Motooka 744,Nishi Ku, Fukuoka 8190395, Japan
[9] Natl Inst Mat Sci NIMS, Res Network & Facil Serv Div, 1-2-1 Sengen, Tsukuba, Ibaraki 3050047, Japan
关键词
Sensors; Microcalorimeters; TES; Solar axions; Monochromatic axion; Fe-57; M1; TRANSITION; RESONANT ABSORPTION; CP CONSERVATION; CONSTRAINTS; INVARIANCE;
D O I
10.1007/s10909-023-02942-w
中图分类号
O59 [应用物理学];
学科分类号
摘要
A Fe-57 nucleus in the solar core could emit a 14.4-keV monochromatic axion through the M1 transition if a hypothetical elementary particle, axion, exists to solve the strong CP problem. Transition edge sensor (TES) X-ray microcalorimeters can detect such axions very efficiently if they are again converted into photons by a Fe-57 absorber. We have designed and produced a dedicated TES array with Fe-57 absorbers for the solar axion search. The iron absorber is set next to the TES, keeping a certain distance to reduce the iron-magnetization effect on the spectroscopic performance. A gold thermal transfer strap connects them. A sample pixel irradiated from a Fe-57 source detected 698 pulses. In contrast to thermal simulations, we consider that the pulses include either events produced in an iron absorber or gold strap at a fraction dependent on the absorption rate of each material. Furthermore, photons deposited on the iron absorber are detected through the strap as intended. The identification of all events still needs to be completed. However, we successfully operated the TES with the unique design under iron magnetization for the first time.
引用
收藏
页码:255 / 264
页数:10
相关论文
共 50 条
  • [31] 14.4 keV X-Ray Michelson Interferometer Design and Core Component Characterization
    Si Shangyu
    Li Zhongliang
    Xue Lian
    Yang Junliang
    Luo Hongxin
    Li Wei
    Zhang Xiaowei
    ACTA OPTICA SINICA, 2023, 43 (04)
  • [32] The 7 keV axion dark matter and the X-ray line signal
    Higaki, Tetsutaro
    Jeong, Kwang Sik
    Takahashi, Fuminobu
    PHYSICS LETTERS B, 2014, 733 : 25 - 31
  • [33] High count-rate study of two TES x-ray microcalorimeters with different transition temperatures
    Lee, Sang-Jun
    Adams, Joseph S.
    Bandler, Simon R.
    Betancourt-Martinez, Gabriele L.
    Chervenak, James A.
    Eckart, Megan E.
    Finkbeiner, Fred M.
    Kelley, Richard L.
    Kilbourne, Caroline A.
    Porter, Frederick S.
    Sadleir, John E.
    Smith, Stephen J.
    Wassell, Edward J.
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2017, 30 (10):
  • [34] Development of TES microcalorimeters for future X-ray missions - art. no. 62662M
    Ferrari, L.
    Dussoni, S.
    Gatti, F.
    Pergolesi, D.
    Gomes, M. Ribeiro
    Valle, R.
    Piro, L.
    Colasanti, L.
    Toniolo, M. Ferrari
    Torrioli, G.
    Bastia, P.
    Space Telescopes and Instrumentation II: Ultraviolet to Gamma Ray, Pts 1 and 2, 2006, 6266 : M2662 - M2662
  • [35] Development of a Real-Time Pulse Processing Algorithm for TES-Based X-Ray Microcalorimeters
    Tan, Hui
    Hennig, Wolfgang
    Warburton, William K.
    Doriese, W. Bertrand
    Kilbourne, Caroline A.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 276 - 280
  • [36] Energy Calibration of High-Resolution X-Ray TES Microcalorimeters With 3 eV Optical Photons
    Jaeckel, F. T.
    Ambarish, C., V
    Christensen, N.
    Gruenke, R.
    Hu, L.
    McCammon, D.
    McPheron, M.
    Meyer, M.
    Nelms, K. L.
    Roy, A.
    Wulf, D.
    Zhang, S.
    Zhou, Y.
    Adams, J. S.
    Bandler, S. R.
    Chervenak, J. A.
    Datesman, A. M.
    Eckart, M. E.
    Ewin, A. J.
    Finkbeiner, F. M.
    Kelley, R.
    Kilbourne, C. A.
    Miniussi, A. R.
    Porter, F. S.
    Sadleir, J. E.
    Sakai, K.
    Smith, S. J.
    Wakeham, N.
    Wassell, E.
    Yoon, W.
    Morgan, K. M.
    Schmidt, D. R.
    Swetz, D. S.
    Ullom, J. N.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2019, 29 (05)
  • [37] SmallSat Solar Axion and Activity X-ray Imager (SSAXI)
    Hong, Jaesub
    Romaine, Suzanne
    Kenter, Almus
    Moore, Christopher
    Reeves, Katherine
    Ramsey, Brian
    Kilaru, Kiranmayee
    Vogel, Julia K.
    Armendariz, Jamie Ruz
    Hudson, Hugh
    Perez, Kerstin
    UV, X-RAY, AND GAMMA-RAY SPACE INSTRUMENTATION FOR ASTRONOMY XXI, 2019, 11118
  • [38] Hidden axion dark matter decaying through mixing with QCD axion and the 3.5 keV X-ray line
    Higaki, Tetsutaro
    Kitajima, Naoya
    Takahashi, Fuminobu
    JOURNAL OF COSMOLOGY AND ASTROPARTICLE PHYSICS, 2014, (12):
  • [39] New solar x-ray constraints on keV axionlike particles
    Beaufort, Cyprien
    Bastero-Gil, Mar
    Luce, Tiffany
    Santos, Daniel
    PHYSICAL REVIEW D, 2023, 108 (08)
  • [40] SEARCH FOR SOLAR X-RAY BRIGHT POINTS AT RADIO, OPTICAL AND X-RAY WAVELENGTHS
    AVERY, LW
    FELDMAN, PA
    GAIZAUSKAS, V
    ROY, JR
    WOLFSON, CJ
    JOURNAL OF THE ROYAL ASTRONOMICAL SOCIETY OF CANADA, 1976, 70 (05) : 265 - 265