Improving the photovoltaic/thermal (PV/T) system by adding the PCM and finned tube heat exchanger

被引:1
|
作者
Al-Hamzawi, Hassan Abdal Haidy [1 ]
Shojaeefard, Mohammad Hassan [1 ]
Sharfabadi, Mohammad Mazidi [2 ]
机构
[1] Iran Univ Sci & Technol, Sch Mech Engn, Hengam Ave, Tehran 1684613114, Iran
[2] Res Inst Petr Ind RIPI, Dev & Optimizat Energy Technol Div, Tehran 1485613111, Iran
关键词
DESALINATION;
D O I
10.1063/5.0179371
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In this study, we aimed to improve the performance of the photovoltaic-thermal (PV/T) system by incorporating phase change material (PCM) into the heat exchanger. A new design for the finned tube heat exchanger layout was introduced, and a comprehensive mathematical model was developed to analyze the heat transfer process and operational efficiency of the PV/T system. The temperature variation of the PV/T system was simulated and validated using real climatic conditions in Baghdad and Tehran. To conduct our analysis, we utilized the OpenFOAM software and enhanced our solver to accurately capture the melting process in the PCM. We also investigated the effects of wind velocity and atmospheric pressure on the performance of the PV/T system. Our findings showed that an increase in wind velocity led to an increase in PV/T efficiency, while an increase in atmospheric pressure resulted in a decrease in efficiency. Additionally, we observed that the Baghdad climate was more sensitive to variations in wind velocity compared to Tehran. In Baghdad and Tehran, the highest obtained water temperatures were 54.3 and 50.1 C-degrees, respectively. Furthermore, a study was conducted to assess the viability of using PV/T (photovoltaic-thermal) technology for hot water production in the Multi-Effect Desalination and Adsorption Desalination cycle. The proposed PV/T system demonstrated an average performance improvement of 26% compared to traditional PV/T systems. During warmer months, the system was capable of producing 0.11 and 0.10 m(3)/h of potable water per month in Baghdad and Tehran, respectively. Furthermore, the system had the potential to generate 170 and 140 kW h of electricity for the respective cities.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] Modeling of Finned-Tube Heat Exchanger Using in Air Conditioning System
    Khotphan, Suphod
    SURANAREE JOURNAL OF SCIENCE AND TECHNOLOGY, 2006, 13 (01): : 20 - 28
  • [22] Finned-tube heat exchanger optimization methodology
    Stewart, SW
    Shelton, SV
    Aspelund, KA
    HEAT TRANSFER ENGINEERING, 2005, 26 (07) : 22 - 28
  • [23] Experiments on the dehumidification performance of a finned tube heat exchanger
    Chuah, YK
    Hung, CC
    Tseng, PC
    HVAC&R RESEARCH, 1998, 4 (02): : 167 - 178
  • [24] Analysis on thermal hydraulic performance of the elliptical tube in the finned-tube heat exchanger by new method
    Wang, Qiang
    Qian, Zuoqin
    Cheng, Junlin
    Huang, Weilong
    Ren, Jie
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 134 : 388 - 397
  • [25] Research on the Thermal Hydraulic Performance and Entropy Generation Characteristics of Finned Tube Heat Exchanger with Streamline Tube
    Qian, Zuoqin
    Wang, Qiang
    Lv, Song
    ENERGIES, 2020, 13 (20)
  • [26] Effect of fins and nanoparticles in the discharge performance of PCM thermal storage system with a multi pass finned tube heat exchange
    Pássaro, João
    Rebola, A.
    Coelho, L.
    Conde, J.
    Evangelakis, G.A.
    Prouskas, C.
    Papageorgiou, D.G.
    Zisopoulou, A.
    Lagaris, I.E.
    Applied Thermal Engineering, 2022, 212
  • [27] Effect of fins and nanoparticles in the discharge performance of PCM thermal storage system with a multi pass finned tube heat exchange
    Passaro, Joao
    Rebola, A.
    Coelho, L.
    Conde, J.
    Evangelakis, G. A.
    Prouskas, C.
    Papageorgiou, D. G.
    Zisopoulou, A.
    Lagaris, I. E.
    APPLIED THERMAL ENGINEERING, 2022, 212
  • [28] Joining by forming technology for thermal applications: A case study of finned tube heat exchanger
    Saltarelli, Riccardo
    Alves, Luis M.
    Fasano, Matteo
    Afonso, Rafael M.
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 59
  • [29] Author Correction: Melting enhancement of PCM in a finned tube latent heat thermal energy storage
    Sameh Ahmed
    Aissa Abderrahmane
    Abdulkafi Mohammed Saeed
    Kamel Guedri
    Abed Mourad
    Obai Younis
    Thongchai Botmart
    Nehad Ali Shah
    Scientific Reports, 12
  • [30] Heat transfer study on finned tube heat exchanger using CFD
    Rajeshkumar, M.
    Logesh, K.
    Thangaraj, M.
    Govindan, S.
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2021, 42 (03) : 239 - 243