Carboxymethylated maltodextrin as a chiral selector for the separation of some basic drug enantiomers using capillary electrophoresis

被引:6
|
作者
Alawadi, Mustafa [1 ]
Fakhari, Ali Reza [1 ]
Bayatloo, Mohammad Reza [1 ]
Nojavan, Saeed [1 ]
机构
[1] Shahid Beheshti Univ, Dept Analyt Chem & Pollutants, Tehran, Iran
关键词
Carboxymethylated maltodextrin; Basic drugs; Capillary electrophoresis; Enantiomer separation; PHARMACEUTICAL FORMULATIONS; AMLODIPINE ENANTIOMERS; IONIC LIQUID; ENANTIOSEPARATION; QUANTIFICATION; CYCLODEXTRIN;
D O I
10.1016/j.chroma.2023.464335
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, carboxymethylated maltodextrin (Cm-MD) was successfully synthesized as an efficient anionic chiral selector and applied for the enantiomer separation of some basic drugs including tramadol, venlafaxine, verapamil, hydroxyzine, citalopram, fluoxetine, and amlodipine by capillary electrophoresis (CE). The synthesized chiral selector was characterized by the nuclear magnetic resonance and Fourier transform infrared spectrophotometry. Under the optimized Cm-MD modified CE conditions (background electrolyte: phosphate buffer (pH 5.0, 50 mM) containing 5% (w/v) Cm-MD; applied voltage: 20 kV; and capillary column temperature: 25 C), successful enantiomer separation of all studied chiral drugs were observed. By comparison of Cm-MD and MD for enantiomer separation of the model drugs, it was revealed that Cm-MD exhibits a higher resolution in comparison to the MD modified CE. This enhanced resolution could be attributed to the electrostatic interactions between the cationic drugs and anionic Cm-MD and opposite direction mobility of the host-guest complex relative to the chiral analyte. The optimized Cm-MD modified CE method was successfully used for the assay of the enantiomers of citalopram and venlafaxine in commercial tablets. The proposed method showed the linear range of 5.0-150.0 mg/L and 10.0-150.0 mg/L for both enantiomers of citalopram and venlafaxine, respectively. The limits of quantification were 5.0 and 10.0 mg/L for the enantiomers of citalopram and venlafaxine, respectively. The limit of detection for all enantiomers was found to be < 3.0 mg/L. Intra-and inter-day RSDs (n = 4) were less than 9.7%. The relative errors were less than 9.4% for all enantiomers. The obtained results in this research show that Cm-MD as a new, efficient and inexpensive chiral selector can be used for enantiomer separation of basic drugs using the CE technique.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Chiral Separation of Indapamide Enantiomers by Capillary Electrophoresis
    Tero-Vescan, Amelia
    Hancu, Gabriel
    Oroian, Mihaela
    Carje, Anca
    ADVANCED PHARMACEUTICAL BULLETIN, 2014, 4 (03) : 267 - 272
  • [22] Chiral separation of fluvastatin enantiomers by capillary electrophoresis
    Trung, Tran Quoc
    Dung, Phan Thanh
    Hoan, Nguyen Ngoc
    Kim, Dae Joong
    Lee, Joo Huyn
    Kim, Kyeong Ho
    ARCHIVES OF PHARMACAL RESEARCH, 2008, 31 (08) : 1066 - 1072
  • [23] Chiral separation of binaphthol enantiomers in capillary electrophoresis
    Wang, RY
    Lu, XN
    Wu, MJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 27 (01) : 73 - 76
  • [24] Chiral separation of fluvastatin enantiomers by capillary electrophoresis
    Tran Quoc Trung
    Phan Thanh Dung
    Nguyen Ngoc Hoan
    Dae Joong Kim
    Joo Huyn Lee
    Kyeong Ho Kim
    Archives of Pharmacal Research, 2008, 31 : 1066 - 1072
  • [25] Chiral capillary electrophoresis as predictor for separation of drug enantiomers in continuous flow zone electrophoresis
    Wind, M
    Hoffmann, P
    Wagner, H
    Thormann, W
    JOURNAL OF CHROMATOGRAPHY A, 2000, 895 (1-2) : 51 - 65
  • [26] Investigation of enantiomeric separation of basic drugs by capillary electrophoresis using clindamycin phosphate as a novel chiral selector
    Chen, Bin
    Du, Yingxiang
    Li, Ping
    ELECTROPHORESIS, 2009, 30 (15) : 2747 - 2754
  • [27] Simultaneous Chiral Separation of Geometry Isomers and Enantiomers of Nateglinide by Capillary Electrophoresis with Mixture of CD Derivations as Chiral Selector
    Bao-hui, Li
    Bao-juan, Tian
    Yun-kai, Lv
    ANALYTICAL LETTERS, 2008, 41 (17) : 3177 - 3186
  • [28] Enantiomeric separation by capillary electrophoresis using a crown ether as chiral selector
    Kuhn, R
    ELECTROPHORESIS, 1999, 20 (13) : 2605 - 2613
  • [29] Enantiomeric separation of basic drugs with hydroxypropyl-β-cyclodextrin as chiral selector by capillary electrophoresis
    Fu, XY
    Lü, JD
    Sun, CR
    Pan, HH
    Chen, YZ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 27 (07) : 790 - 793
  • [30] Carboxymethylated cyclosophoraose as a novel chiral additive for the stereoisomeric separation of some flavonoids by capillary electrophoresis
    Jeon, Yukyoung
    Kwon, Chanho
    Cho, Eunae
    Jung, Seunho
    CARBOHYDRATE RESEARCH, 2010, 345 (16) : 2408 - 2412