A Novel Computation of Delay Margin Based on Grey Wolf Optimisation for a Load Frequency Control of Two-Area-Network Power Systems

被引:3
|
作者
Ibrahim, Mohammad Haziq [1 ]
Peng, Ang Swee [1 ]
Dani, Muhammad Norfauzi [1 ]
Khalil, Ashraf [2 ]
Law, Kah Haw [1 ]
Yunus, Sharina [1 ]
Rahman, Mohammad Ishlah [3 ]
Au, Thien Wan [4 ]
机构
[1] Univ Teknol Brunei, Elect & Elect Engn Programme Area, BE-1410 Bandar Seri Begawan, Brunei
[2] Tech Univ Denmark, DTU Engn Technol, DK-2750 Ballerup, Denmark
[3] Minist Educ, Politeknik Brunei, Sch Sci & Engn, Bandar Seri Begawan, Brunei
[4] Univ Teknol Brunei, Sch Comp & Informat, BE-1410 Bandar Seri Begawan, Brunei
关键词
communication time delay; delay margin; delay dependent stability; grey wolf optimisation; two-area load-frequency control; DEPENDENT STABILITY; LINEAR-SYSTEMS; CONSTANT; CRITERIA;
D O I
10.3390/en16062860
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In classical power systems, frequency measurements are transferred via a specialised communication channel, resulting in time delay. The time delay plays a major role in a power system, which can reduce the dynamic performance of the load-frequency control (LFC) system and can destabilise the system. The research to date has tended to focus on developing a new algorithm to determine the delay margin (DM) rather than looking into a hybrid algorithm which includes a nature-inspired metaheuristic optimisation technique. This paper introduces a novel method for computing the DM based on grey wolf optimisation (GWO), specifically for the constant time delay. In the proposed method, GWO is employed to optimise the minimum error of the spectral radius and to determine the best design variable of the crossing frequency. With the help of the proposed method, the sweeping range is no longer required, which improves the accuracy of the result. To evaluate the proposed method, a two-area network power system is considered as a case study. Furthermore, the effect of the PI controller gains on the DM is taken into account. The proposed method efficacy is demonstrated by comparing it with the most recently published methods. The results demonstrate that the proposed method is remarkably better than the existing methods found in the literature, where the smallest percentage inaccuracy using the simulation-based DM based on GWO is found to be 0.000%.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Load frequency control for two-area hybrid microgrids using model predictive control optimized by grey wolf-pattern search algorithm
    Amiri, Farhad
    Hatami, Alireza
    SOFT COMPUTING, 2023, 27 (23) : 18227 - 18243
  • [32] Delay-dependent Robust Load Frequency Control for Time Delay Power Systems
    Zhang, Chuan-ke
    Jiang, Lin
    Wu, Q. H.
    He, Yong
    Wu, Min
    2013 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PES), 2013,
  • [33] H∞ Load Frequency Control Design Based on Delay Discretization Approach for Interconnected Power Systems with Time Delay
    Pradhan, Subrat Kumar
    Das, Dushmanta Kumar
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2021, 9 (06) : 1468 - 1477
  • [34] H∞ Load Frequency Control Design Based on Delay Discretization Approach for Interconnected Power Systems with Time Delay
    Subrat Kumar Pradhan
    Dushmanta Kumar Das
    JournalofModernPowerSystemsandCleanEnergy, 2021, 9 (06) : 1468 - 1477
  • [35] Stability delay margin computation of multi-area load frequency control system with electric vehicle using critical eigenvalue tracing method
    Aydin, Omer
    Sonmez, Sahin
    Ayasun, Saffet
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2023, 45 (05) : 874 - 885
  • [36] Effects of fractional-order PI controller on delay margin in single-area delayed load frequency control systems
    Vedat ?ELIK
    Mahmut Temel ?ZDEMIR
    Kwang Y.LEE
    JournalofModernPowerSystemsandCleanEnergy, 2019, 7 (02) : 380 - 389
  • [37] Delay -Dependent Stability Analysis for Load Frequency Control Systems with Two Delay Components
    Liu, Pipi
    Huang, Zhanjun
    Liu, Yipeng
    Wang, Zhanshan
    PROCEEDINGS OF THE 30TH CHINESE CONTROL AND DECISION CONFERENCE (2018 CCDC), 2018, : 6476 - 6481
  • [38] Effects of fractional-order PI controller on delay margin in single-area delayed load frequency control systems
    Celik, Vedat
    Ozdemir, Mahmut Temel
    Lee, Kwang Y.
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2019, 7 (02) : 380 - 389
  • [39] Model Predictive Load Frequency Control of two-area Interconnected Time Delay Power System with TCSC
    Deng, Yan
    Liu, Wenze
    2017 2ND ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2017), 2017, 199
  • [40] Differential Evolution based IMC-PID Design for Load frequency control of Two-area power systems
    Sonker, Bheem
    Kumar, Deepak
    Sreeram, Victor
    Samuel, Paulson
    2020 AUSTRALIAN AND NEW ZEALAND CONTROL CONFERENCE (ANZCC 2020), 2020, : 67 - 70