A Novel Computation of Delay Margin Based on Grey Wolf Optimisation for a Load Frequency Control of Two-Area-Network Power Systems

被引:3
|
作者
Ibrahim, Mohammad Haziq [1 ]
Peng, Ang Swee [1 ]
Dani, Muhammad Norfauzi [1 ]
Khalil, Ashraf [2 ]
Law, Kah Haw [1 ]
Yunus, Sharina [1 ]
Rahman, Mohammad Ishlah [3 ]
Au, Thien Wan [4 ]
机构
[1] Univ Teknol Brunei, Elect & Elect Engn Programme Area, BE-1410 Bandar Seri Begawan, Brunei
[2] Tech Univ Denmark, DTU Engn Technol, DK-2750 Ballerup, Denmark
[3] Minist Educ, Politeknik Brunei, Sch Sci & Engn, Bandar Seri Begawan, Brunei
[4] Univ Teknol Brunei, Sch Comp & Informat, BE-1410 Bandar Seri Begawan, Brunei
关键词
communication time delay; delay margin; delay dependent stability; grey wolf optimisation; two-area load-frequency control; DEPENDENT STABILITY; LINEAR-SYSTEMS; CONSTANT; CRITERIA;
D O I
10.3390/en16062860
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In classical power systems, frequency measurements are transferred via a specialised communication channel, resulting in time delay. The time delay plays a major role in a power system, which can reduce the dynamic performance of the load-frequency control (LFC) system and can destabilise the system. The research to date has tended to focus on developing a new algorithm to determine the delay margin (DM) rather than looking into a hybrid algorithm which includes a nature-inspired metaheuristic optimisation technique. This paper introduces a novel method for computing the DM based on grey wolf optimisation (GWO), specifically for the constant time delay. In the proposed method, GWO is employed to optimise the minimum error of the spectral radius and to determine the best design variable of the crossing frequency. With the help of the proposed method, the sweeping range is no longer required, which improves the accuracy of the result. To evaluate the proposed method, a two-area network power system is considered as a case study. Furthermore, the effect of the PI controller gains on the DM is taken into account. The proposed method efficacy is demonstrated by comparing it with the most recently published methods. The results demonstrate that the proposed method is remarkably better than the existing methods found in the literature, where the smallest percentage inaccuracy using the simulation-based DM based on GWO is found to be 0.000%.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Load Frequency Control of Two Area and Multi Source Power System Using Grey Wolf Optimization Algorithm
    Dogan, Ahmet
    2019 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONICS ENGINEERING (ELECO 2019), 2019, : 81 - 84
  • [2] A Novel Rekasius Substitution Based Exact Method for Delay Margin Analysis of Multi-Area Load Frequency Control Systems
    Cao, Yulei
    Li, Chongtao
    He, Tingyi
    Chen, Yiping
    Li, Shengnan
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2021, 36 (06) : 5222 - 5234
  • [3] Gain and phase margins-based delay margin computation of load frequency control systems using Rekasius substitution
    Sonmez, Sahin
    Ayasun, Saffet
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2019, 41 (12) : 3385 - 3395
  • [4] A Novel Grey Wolf Optimizer Based Load Frequency Controller for Renewable Energy Sources Integrated Thermal Power Systems
    Can, Ozay
    Ozturk, Ali
    Eroglu, Hasan
    Kotb, Hossam
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2022, 49 (15) : 1248 - 1259
  • [5] Stability Delay Margin Computation of Load Frequency Control System with Demand Response
    Katipoglu, Deniz
    Sonmez, Sahin
    Ayasun, Saffet
    2019 IEEE 1ST GLOBAL POWER, ENERGY AND COMMUNICATION CONFERENCE (GPECOM2019), 2019, : 473 - 478
  • [6] Load frequency control of interconnected power system using grey wolf optimization
    Guha, Dipayan
    Roy, Provas Kumar
    Banerjee, Subrata
    SWARM AND EVOLUTIONARY COMPUTATION, 2016, 27 : 97 - 115
  • [7] Multi-Area Load Frequency Control of Hydro-Thermal-Wind Power Based on Improved Grey Wolf Optimization Algorithm
    Kong, Fannie
    Li, Jinfang
    Yang, Daliang
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2020, 26 (06) : 32 - 39
  • [8] DELAY MARGIN COMPUTATION FOR LOAD FREQUENCY CONTROL SYSTEM WITH PLUG-IN ELECTRIC VEHICLES
    Khalil, Ashraf
    Peng, Ang S.
    INTERNATIONAL JOURNAL OF POWER AND ENERGY SYSTEMS, 2018, 38 (03): : 115 - 131
  • [9] Grey Wolf Algorithm based Control Strategy for Load Frequency Control in Coordination with IPFC
    Shankar, Ravi
    2018 INTERNATIONAL CONFERENCE ON RECENT INNOVATIONS IN ELECTRICAL, ELECTRONICS & COMMUNICATION ENGINEERING (ICRIEECE 2018), 2018, : 569 - 574
  • [10] Application of grey wolf optimization algorithm for load frequency control in multi-source single area power system
    Nikhil Paliwal
    Laxmi Srivastava
    Manjaree Pandit
    Evolutionary Intelligence, 2022, 15 : 563 - 584