Improvements in the Compression Filter and Calibration Factor of the Progressive Pulse Compression Technique

被引:0
|
作者
Salazar, Cesar M. [1 ,2 ]
Cheong, Boonleng [1 ]
Palmer, Robert D. [1 ,3 ]
Schvartzman, David [1 ,3 ]
Ryzhkov, Alexander V. [1 ,4 ]
机构
[1] Univ Oklahoma, Adv Radar Res Ctr, Norman, OK 73019 USA
[2] Univ Oklahoma, Cooperat Inst Severe & High Impact Weather Res and, Norman, OK 73019 USA
[3] Univ Oklahoma, Sch Meteorol, Norman, OK 73019 USA
[4] Univ Oklahoma, Cooperat Inst Severe & High Impact Weather Res & O, Sch Meteorol, Norman, OK 73019 USA
关键词
Radar; Meteorological radar; Sensitivity; Radar polarimetry; Urban areas; Reflectivity; Doppler radar; Bandwidth; pulse compression; signal processing; solid-state amplifier; weather radar; WEATHER RADAR; WAVE-FORM; DESIGN;
D O I
10.1109/TGRS.2024.3353174
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Progressive pulse compression (PPC) was introduced to mitigate the need for a fill pulse in pulse-compression-based radar systems. It provides a method for recovering signals in the blind-range region created by the transmission of relatively long pulses. However, the initial implementation of PPC has limitations that need to be addressed for it to be more useful for meteorological applications. The proposed updated algorithm, named herein PPC+, brings significant improvements to mitigate these limitations. The methodology of PPC+ is similar to that of PPC, except that it uses a set of improved pulse compression filters. The improved compression filters are designed based on an amplitude modulation approach and are generated by multiplying the original filter by a range-dependent window. The window can be divided into two sections, the first part has a number of nulled samples used for mitigating the main lobe migration, and the remaining portion is a number of tapered samples to alleviate the "shoulder" effect from range sidelobes. Also, in contrast to PPC, the calibration factor used in PPC+ is further tuned to account for the tapering used in the improved compression filters. The PPC+ technique has been tested using data collected with PX-1000, a polarimetric X-band transportable solid-state radar system designed and operated by the Advanced Radar Research Center (ARRC) at The University of Oklahoma, and it is implemented and operational on that system (data available at https://radarhub.arrc.ou.edu). This technique has also been implemented on Horus, a fully digital phased array radar recently completed at the ARRC.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 50 条
  • [31] Imaging system for intravascular ultrasonography using pulse compression technique
    Hu, ZQ
    Moriya, T
    Tanahashi, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2001, 40 (5B): : 3896 - 3899
  • [32] A Pulse Compression Technique for Improving the Temporal Resolution of Ultrasonic Testing
    Jiao, Jingpin
    Ma, Ting
    Hou, Song
    Wu, Bin
    He, Cunfu
    JOURNAL OF TESTING AND EVALUATION, 2018, 46 (03) : 1238 - 1249
  • [33] Improvement of Radar Performance Using LFM Pulse Compression Technique
    Intyas, Ilfiyantri
    Hasanah, Rahmawati
    Hidayat, M. Reza
    Hasanah, Barokatun
    Suskmono, Andriyan B.
    Munir, Achmad
    5TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATICS 2015, 2015, : 302 - 307
  • [34] Research on the imaging of concrete defect based on the pulse compression technique
    Chang-Zheng Li
    Bi-Xing Zhang
    Fang-Fang Shi
    Fu-Li Xie
    Applied Geophysics, 2013, 10 : 337 - 348
  • [35] Synthetic aperture technique for echographic focusing based on pulse compression
    Biagi, E
    Masotti, L
    Rossi, I
    Scabia, M
    2004 IEEE Ultrasonics Symposium, Vols 1-3, 2004, : 1425 - 1428
  • [36] Pulse compression technique considering velocity dispersion of guided wave
    Toiyama, K.
    Hayashi, T.
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOL 27A AND 27B, 2008, 975 : 587 - +
  • [37] Pulse compression technique applied to ultrasonic nondestructive testing of concrete
    Chang, YF
    Lee, CH
    JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 2004, 27 (02) : 187 - 192
  • [38] EVALUATION OF A PULSE-COMPRESSION TECHNIQUE FOR ULTRASOUND SPECKLE REDUCTION
    RAO, NAH
    IAUBRY, WM
    ELECTRONICS LETTERS, 1993, 29 (21) : 1900 - 1901
  • [39] Investigation of a pulse compression technique for medical ultrasound: A simulation study
    Rao, N.A.H.
    Medical and Biological Engineering and Computing, 1994, 32 (02): : 181 - 188
  • [40] Imaging system for intravascular ultrasonography using pulse compression technique
    Hu, Zhiqiang
    Moriya, Tadashi
    Tanahashi, Yoshikatsu
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2001, 40 (5 B): : 3896 - 3899