Cardiac computed tomography angiography with and without bolus tracking methods in infants with congenital heart disease

被引:1
|
作者
Yoshiura, Takayuki [1 ,2 ]
Masuda, Takanori [3 ]
Tahara, Masahiro [4 ]
Kobayashi, Yukie [2 ]
Kikuhara, Yukari [2 ]
Ishibashi, Toru [2 ]
Nonaka, Haruki [2 ]
Oku, Takayuki [2 ]
Sato, Tomoyasu [2 ]
Funama, Yoshinori [5 ]
机构
[1] Kumamoto Univ, Grad Sch Hlth Sci, 4-24-1 Kuhonji, Kumamoto 8620976, Japan
[2] Tsuchiya Gen Hosp, Dept Med Technol, 3-30 Nakajima Cho, Hiroshima 7308655, Japan
[3] Kawasaki Univ Med Welf, Fac Hlth Sci & Technol, Dept Radiol Technol, 288 Matsushima, Kurashiki, Okayama 7010193, Japan
[4] Hiroshima Cent St Childrens Clin, 7-1 Mikawa Cho, Hiroshima 7300029, Japan
[5] Kumamoto Univ, Fac Life Sci, Dept Med Radiat Sci, 4-24-1 Kuhonji, Kumamoto 8620976, Japan
关键词
RADIATION-EXPOSURE; PEDIATRIC-PATIENTS; CT ANGIOGRAPHY; TETRALOGY; PREVALENCE; CHILDREN; SOCIETY; FALLOT; TRENDS; CANCER;
D O I
10.1093/rpd/ncad295
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The study investigated radiation dose, vascular computed tomography (CT) enhancement and image quality of cardiac computed tomography angiography (CCTA) with and without bolus tracking (BT) methods in infants with congenital heart disease (CHD). The volume CT dose index (CTDIvol) and dose length product (DLP) were recorded for all CT scans, and the effective dose was obtained using a conversion factors. The CT number for the ascending aorta (AO) and pulmonary artery (PA), image noise of muscle tissue and contrast-to-noise ratio (CNR) were measured and calculated. The median values in the groups with and without BT were 2.20 mGy versus 0.44 mGy for CTDIvol, 8.10 mGy<middle dot>cm versus 6.20 mGy<middle dot>cm for DLP, and 0.66 mSv versus 0.51 mSv for effective dose (p < 0.001). There were no statistical differences in vascular CT enhancement, image noise, and CNR. CCTA without BT methods can reduce the radiation dose while maintaining vascular CT enhancement and image quality compared to CCTA with BT methods.
引用
收藏
页码:251 / 258
页数:8
相关论文
共 50 条
  • [31] Image Quality of Coronary Computed Tomography Angiography with 320-Row Area Detector Computed Tomography in Children with Congenital Heart Disease
    Tada, Akihiro
    Sato, Shuhei
    Kanie, Yuichiro
    Tanaka, Takashi
    Inai, Ryota
    Akagi, Noriaki
    Morimitsu, Yusuke
    Kanazawa, Susumu
    PEDIATRIC CARDIOLOGY, 2016, 37 (03) : 497 - 503
  • [32] Cardiac CT in the Preoperative Diagnostics of Neonates with Congenital Heart Disease: Radiation Dose Optimization by Omitting Test Bolus or Bolus Tracking
    Schindler, Philipp
    Kehl, Hans-Gerd
    Wildgruber, Moritz
    Heindel, Walter
    Schuelke, Christoph
    ACADEMIC RADIOLOGY, 2020, 27 (05) : E102 - E108
  • [33] Optimal placement of the region of interest for bolus tracking on brain computed tomography angiography in Beagle dogs
    Park, Sieun
    Jang, Min
    Lee, Kija
    Choi, Hojung
    Lee, Youngwon
    Park, Inchul
    Choi, Sooyoung
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2021, 83 (08): : 1196 - 1201
  • [34] Computed tomography of the airways and lungs in congenital heart disease
    Jordan B. Rapp
    Ammie M. White
    Hansel J. Otero
    David M. Biko
    Pediatric Radiology, 2022, 52 : 2529 - 2537
  • [35] Computed tomography for imaging of pediatric congenital heart disease
    Glaser-Gallion, N.
    Stinn, B.
    Alkadhi, H.
    Lell, M.
    Goo, H. W.
    Paul, J-F
    Wildermuth, S.
    Leschka, S.
    RADIOLOGE, 2011, 51 (01): : 38 - 43
  • [36] Computed tomography of the airways and lungs in congenital heart disease
    Rapp, Jordan B.
    White, Ammie M.
    Otero, Hansel J.
    Biko, David M.
    PEDIATRIC RADIOLOGY, 2022, 52 (13) : 2529 - 2537
  • [37] Use of 320-Detector Computed Tomographic Angiography for Infants and Young Children with Congenital Heart Disease
    Al-Mousily, Faris
    Shifrin, Roger Y.
    Fricker, Frederick J.
    Feranec, Nicholas
    Quinn, Nancy S.
    Chandran, Arun
    PEDIATRIC CARDIOLOGY, 2011, 32 (04) : 426 - 432
  • [38] COMPUTED-TOMOGRAPHY IN CONGENITAL HEART-DISEASE
    FARMER, DW
    LIPTON, MJ
    WEBB, WR
    RINGERTZ, H
    HIGGINS, CB
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) : 677 - 687
  • [39] Three-dimensional helical computed tomographic angiography in neonates and infants with complex congenital heart disease
    Kawano, T
    Ishii, M
    Takagi, J
    Maeno, Y
    Eto, G
    Sugahara, Y
    Toshima, T
    Yasunaga, H
    Kawara, T
    Todo, K
    Kato, H
    AMERICAN HEART JOURNAL, 2000, 139 (04) : 654 - 660
  • [40] Use of 320-Detector Computed Tomographic Angiography for Infants and Young Children with Congenital Heart Disease
    Faris Al-Mousily
    Roger Y. Shifrin
    Frederick J. Fricker
    Nicholas Feranec
    Nancy S. Quinn
    Arun Chandran
    Pediatric Cardiology, 2011, 32 : 426 - 432