Caster Walker GAIT Trainer (CGT): A robotic assistive device

被引:3
|
作者
Singh, Ramanpreet [1 ]
Pathak, Vimal Kumar [1 ]
Sharma, Abhishek [1 ]
Chakraborty, Debaditya [1 ]
Saxena, Kuldeep K. [2 ]
Prakash, C. [3 ]
Buddhi, Dharam [4 ]
Salem, Karrar Hazim [5 ]
机构
[1] Manipal Univ Jaipur, Dept Mech Engn, Jaipur 303007, Rajasthan, India
[2] GLA Univ, Dept Mech Engn, Mathura 281406, Uttar Pradesh, India
[3] Lovely Profess Univ, Div Res & Dev, Phagwara, India
[4] Uttaranchal Univ, Div Res & Innovat, Dehra Dun 248007, Uttarakhand, India
[5] Al Mustaqbal Univ Coll, Pharm Dept, Hillah 51001, Iraq
关键词
Defect-free; Mechanism synthesis; Gait rehabilitation; Caster Walker Gait Trainer; Lower limb; CGT; TLBO; Teaching-Learning-Based-Optimization; Stephenson III six-bar mechanism; MECHANICAL DESIGN; STROKE; REHABILITATION; OPTIMIZATION; LINKAGES; WALKING; PEOPLE;
D O I
10.1016/j.robot.2022.104302
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Stroke has become one of the leading causes of lower limb paresis. Costing the patients, a fortune for its diagnosis and prognosis. Clinical experimentations have proven that one can regain ambulation if the rehabilitation is started in the acute or sub-acute stage. Traditional mode of rehabilitation include manual therapies which are labor-intensive and time consuming. Therefore, robotic training are preferred over manual therapies. Nevertheless, there are some limitations such as devices are bulky and complex, some are not portable, others need body weight support system, and costly. To address such issues, this paper proposes development of a new Caster Walker Gait Trainer (CGT) for gait rehabilitation. CGT is an end-effector based passive device in which Stephenson III six-bar linkage has been implemented to mimic the kinematics of a healthy gait. The trainer device uses a belt-pulley system for providing motion to the linkage. The lower limb of the patient gets the drive as he/she pushes the cater walker forward or backward. The paper also proposed the optimal design of defect-free Stephenson III six-bar linkage using loop-by-loop approach. To design the linkage, an optimal problem is formulated, and tear drop ankle trajectory is desired. The optimization problem is solved using a nature-inspired algorithm and it is found that the trajectory generated by the synthesized mechanism is able to mimic the desired trajectory. Then using the notion of inverse kinematics, hip and knee trajectories are obtained from the generated ankle trajectory for validation. (c) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Overground Robotic Gait Trainer mTPAD Improves Gait Symmetry and Weight Bearing in Stroke Survivors
    Stramel, Danielle Marie
    Winterbottom, Lauren
    Stein, Joel
    Agrawal, Sunil K.
    BIOENGINEERING-BASEL, 2023, 10 (06):
  • [22] A Novel Robotic Assistive Device for Stroke-Rehabilitation
    McConnell, Alistair
    Kong, Xianwen
    Vargas, Patricia A.
    2014 23RD IEEE INTERNATIONAL SYMPOSIUM ON ROBOT AND HUMAN INTERACTIVE COMMUNICATION (IEEE RO-MAN), 2014, : 917 - 923
  • [23] A Wearable Robotic Device for Assistive Navigation and Object Manipulation
    Jin, Lingqiu
    Zhang, He
    Ye, Cang
    2021 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS), 2021, : 765 - 770
  • [24] Development of a Holonomic Robotic Wheeled Walker for Persons with Gait Disorder
    Arogunjo, Ezekiel Olayiwola
    Markus, Elisha D.
    Yskandar, Hamam
    2019 OPEN INNOVATIONS CONFERENCE (OI), 2019, : 159 - 164
  • [25] Balance Gait Controller for a Bipedal Robotic Walker With Foot Slip
    Mihalec, Marko
    Yi, Jingang
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2023, 28 (04) : 2012 - 2019
  • [26] A Novel Robotic Walker for Over-Ground Gait Rehabilitation
    Ye, Jing
    Reyes, Francisco A.
    Yu, Haoyong
    CONVERGING CLINICAL AND ENGINEERING RESEARCH ON NEUROREHABILITATION II, VOLS 1 AND 2, 2017, 15 : 1223 - 1227
  • [27] Trainer variability during step training after spinal cord injury: Implications for robotic gait-training device design
    Galvez, Jose A.
    Budovitch, Amy
    Harkema, Susan J.
    Reinkensmeyer, David J.
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2011, 48 (02): : 147 - 159
  • [28] EFFECTS OF LUMBOSACRAL ASSISTIVE DEVICE ON NORMAL DISTANCE GAIT CHARACTERISTICS
    STREICH, K
    WOOD, C
    BRUCKNER, J
    PHYSICAL THERAPY, 1987, 67 (05): : 783 - 783
  • [29] Development of Gait Assistive Device Using Pneumatic Artificial Muscle
    Hashimoto, Yusuke
    Nakanishi, Yasutaka
    Saga, Norihiko
    Nagase, Jun-ya
    Satoh, Toshiyuki
    2016 JOINT 8TH INTERNATIONAL CONFERENCE ON SOFT COMPUTING AND INTELLIGENT SYSTEMS (SCIS) AND 17TH INTERNATIONAL SYMPOSIUM ON ADVANCED INTELLIGENT SYSTEMS (ISIS), 2016, : 710 - 713
  • [30] HYBRID: Ambulatory Robotic Gait Trainer with Movement Induction and Partial Weight Support
    Urendes, Eloy
    Asin-Prieto, Guillermo
    Ceres, Ramon
    Garcia-Carmona, Rodrigo
    Raya, Rafael
    Pons, Jose L.
    SENSORS, 2019, 19 (21)