Adaptive model-based Magnetic Resonance

被引:3
|
作者
Beracha, Inbal [1 ]
Seginer, Amir [2 ]
Tal, Assaf [1 ,3 ]
机构
[1] Weizmann Inst Sci, Dept Chem & Biol Phys, Rehovot, Israel
[2] Siemens Healthcare Ltd, Rosh Haayeen, Rosh Haayeen, Israel
[3] Weizmann Inst Sci, Dept Chem & Biol Phys, IL-7610001 Rehovot, Israel
基金
以色列科学基金会;
关键词
adaptive MR; Bayesian estimation; model-based reconstruction; qMRI; quantitative MR; real-time MRI; PROSPECTIVE MOTION CORRECTION; COMPRESSED-SENSING MRI; REAL-TIME MRI; IMAGE-RECONSTRUCTION; N-ACETYLASPARTATE; RELAXATION-TIMES; BRAIN; QUANTIFICATION; ACQUISITION; METABOLITES;
D O I
10.1002/mrm.29688
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeConventional sequences are static in nature, fixing measurement parameters in advance in anticipation of a wide range of expected tissue parameter values. We set out to design and benchmark a new, personalized approach-termed adaptive MR-in which incoming subject data is used to update and fine-tune the pulse sequence parameters in real time. MethodsWe implemented an adaptive, real-time multi-echo (MTE) experiment for estimating T(2)s. Our approach combined a Bayesian framework with model-based reconstruction. It maintained and continuously updated a prior distribution of the desired tissue parameters, including T-2, which was used to guide the selection of sequence parameters in real time. ResultsComputer simulations predicted accelerations between 1.7- and 3.3-fold for adaptive multi-echo sequences relative to static ones. These predictions were corroborated in phantom experiments. In healthy volunteers, our adaptive framework accelerated the measurement of T-2 for n-acetyl-aspartate by a factor of 2.5. ConclusionAdaptive pulse sequences that alter their excitations in real time could provide substantial reductions in acquisition times. Given the generality of our proposed framework, our results motivate further research into other adaptive model-based approaches to MRI and MRS.
引用
收藏
页码:839 / 851
页数:13
相关论文
共 50 条
  • [41] VALIDATION OF A BRACHIAL OSCILLOMETRY AND MODEL-BASED ESTIMATE OF STROKE VOLUME AGAINST MAGNETIC RESONANCE IMAGING
    Weber, T.
    Feistritzer, H.
    Klug, G.
    Hametner, B.
    Wassertheurer, S.
    Metzler, B.
    JOURNAL OF HYPERTENSION, 2018, 36 : E296 - E296
  • [42] Geometry-driven-diffusion filtering of magnetic resonance images using model-based conductance
    Bajla, I
    Holländer, I
    MACHINE VISION AND APPLICATIONS, 2001, 12 (05) : 223 - 237
  • [43] Identifying the neural dynamics of category decisions with computational model-based functional magnetic resonance imaging
    Emily M. Heffernan
    Juliana D. Adema
    Michael L. Mack
    Psychonomic Bulletin & Review, 2021, 28 : 1638 - 1647
  • [44] Model-based separation filtering of magnetic data
    Pilkington, M
    Cowan, DR
    GEOPHYSICS, 2006, 71 (02) : L17 - L23
  • [45] Model-Based Reconstruction for Magnetic Particle Imaging
    Knopp, Tobias
    Sattel, Timo F.
    Biederer, Sven
    Rahmer, Juergen
    Weizenecker, Juergen
    Gleich, Bernhard
    Borgert, Joern
    Buzug, Thorsten M.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (01) : 12 - 18
  • [46] Hybrid model-based adaptive fuzzy control system
    Chen, JY
    PROCEEDINGS OF THE 2002 IEEE INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS, VOL 1 & 2, 2002, : 1126 - 1131
  • [47] Model-based optimization of adaptive external counterpulsation therapy
    Weyer, Soeren
    Weber, Hannes
    Kleeberg, Christian
    Leonhardt, Steffen
    Teichmann, Daniel
    INTERNATIONAL JOURNAL OF MODELING SIMULATION AND SCIENTIFIC COMPUTING, 2016, 7 (02)
  • [48] ADAPTIVE MODEL-BASED CONTROL USING NEURAL NETWORKS
    MILLS, PM
    ZOMAYA, AY
    TADE, MO
    INTERNATIONAL JOURNAL OF CONTROL, 1994, 60 (06) : 1163 - 1192
  • [49] Adaptive Stabilization of Model-Based Networked Control Systems
    Garcia, Eloy
    Antsaklis, Panos J.
    2011 AMERICAN CONTROL CONFERENCE, 2011, : 1094 - 1099
  • [50] Model-based adaptive filtering of dielectric elastomer loudspeakers
    Garnell E.
    Doaré O.
    Rouby C.
    AES: Journal of the Audio Engineering Society, 2021, 69 (06): : 389 - 397