Sonoelastography for Testicular Tumor Identification: A Systematic Review and Meta-Analysis of Diagnostic Test Accuracy

被引:6
|
作者
Lai, Derek Ka-Hei [1 ]
Cheng, Ethan Shiu-Wang [2 ]
Mao, Ye-Jiao [1 ]
Zheng, Yi [1 ]
Yao, Ke-Yu [3 ]
Ni, Ming [4 ,5 ]
Zhang, Ying-Qi [6 ]
Wong, Duo Wai-Chi [1 ]
Cheung, James Chung-Wai [1 ,7 ]
机构
[1] Hong Kong Polytech Univ, Fac Engn, Dept Biomed Engn, Hong Kong, Peoples R China
[2] Hong Kong Polytech Univ, Fac Engn, Dept Elect & Informat Engn, Hong Kong, Peoples R China
[3] Imperial Coll, Dept Mat, London SW7 2AZ, England
[4] Shanghai Jiao Tong Univ, Ruijin Hosp, Sch Med, Dept Orthopaed, Shanghai 200240, Peoples R China
[5] Shanghai Jiao Tong Univ, Ruijin Hosp, Shanghai Inst Traumatol & Orthopaed, Sch Med,Lab Prevent & Treatment Bone & Joint Dis, Shanghai 200240, Peoples R China
[6] Tongji Univ, Tongji Hosp, Sch Med, Dept Orthopaed, Shanghai 200065, Peoples R China
[7] Hong Kong Polytech Univ, Res Inst Smart Ageing, Hong Kong, Peoples R China
关键词
ultrasound elastography; malignancy; seminoma; scrotum; Leydig cell; Sertoli cell; CONTRAST-ENHANCED ULTRASOUND; SHEAR-WAVE ELASTOGRAPHY; TIME TISSUE ELASTOGRAPHY; LEYDIG-CELL TUMORS; MULTIPARAMETRIC US; DIFFERENTIAL-DIAGNOSIS; SCROTAL ULTRASOUND; CANCER; FEATURES; UPDATE;
D O I
10.3390/cancers15153770
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary Testicular cancer is a prevalent malignancy in young men aged 15 to 35 years. Sonoelastography is an emerging technique for distinguishing between non-neoplasms, benignities, and malignancies by characterizing the tissue stiffness of testes. This review provides a summary of studies on the diagnostic accuracy of sonoelastography for identifying benign and malignant lesions, as well as tumors and non-tumors. The objective of this review was to summarize the applications of sonoelastography in testicular tumor identification and inquire about their test performances. Two authors independently searched English journal articles and full conference papers from CINAHL, Embase, IEEE Xplore(& REG;), PubMed, Scopus, and Web of Science from inception and organized them into a PIRO (patient, index test, reference test, outcome) framework. Eleven studies (n = 11) were eligible for data synthesis, nine of which (n = 9) utilized strain elastography and two (n = 2) employed shear-wave elastography. Meta-analyses were performed on the distinction between neoplasm (tumor) and non-neoplasm (non-tumor) from four study arms and between malignancy and benignity from seven study arms. The pooled sensitivity of classifying malignancy and benignity was 86.0% (95%CI, 79.7% to 90.6%). There was substantial heterogeneity in the classification of neoplasm and non-neoplasm and in the specificity of classifying malignancy and benignity, which could not be addressed by the subgroup analysis of sonoelastography techniques. Heterogeneity might be associated with the high risk of bias and applicability concern, including a wide spectrum of testicular pathologies and verification bias in the reference tests. Key technical obstacles in the index test were manual compression in strain elastography, qualitative observation of non-standardized color codes, and locating the Regions of Interest (ROI), in addition to decisions in feature extractions. Future research may focus on multiparametric sonoelastography using deep learning models and ensemble learning. A decision model on the benefits-risks of surgical exploration (reference test) could also be developed to direct the test-and-treat strategy for testicular tumors.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] Diagnostic test accuracy of ADC values for identification of clear cell renal cell carcinoma: systematic review and meta-analysis
    Tordjman, Mickael
    Mali, Rahul
    Madelin, Guillaume
    Prabhu, Vinay
    Kang, Stella K.
    EUROPEAN RADIOLOGY, 2020, 30 (07) : 4023 - 4038
  • [32] Meta-analysis for the diagnostic accuracy of a test?
    McDonough, PG
    FERTILITY AND STERILITY, 1999, 71 (02) : 391 - 392
  • [33] Diagnostic accuracy of point-of-care ultrasound for paediatric testicular torsion: a systematic review and meta-analysis
    Mori, Takaaki
    Ihara, Takateru
    Nomura, Osamu
    EMERGENCY MEDICINE JOURNAL, 2023, 40 (02) : 140 - 146
  • [34] Diagnostic test accuracy of ADC values for identification of clear cell renal cell carcinoma: systematic review and meta-analysis
    Mickael Tordjman
    Rahul Mali
    Guillaume Madelin
    Vinay Prabhu
    Stella K. Kang
    European Radiology, 2020, 30 : 4023 - 4038
  • [35] Diagnostic Accuracy of the ID Migraine: A Systematic Review and Meta-Analysis
    Cousins, Grainne
    Hijazze, Samira
    Van de Laar, Floris A.
    Fahey, Tom
    HEADACHE, 2011, 51 (07): : 1140 - 1148
  • [36] The diagnostic accuracy of procalcitonin for bacteraemia: a systematic review and meta-analysis
    Hoeboer, S. H.
    van der Geest, P. J.
    Nieboer, D.
    Groeneveld, A. B. J.
    CLINICAL MICROBIOLOGY AND INFECTION, 2015, 21 (05) : 474 - 481
  • [37] Diagnostic accuracy of tests for leprosy: a systematic review and meta-analysis
    Gurung, P.
    Gomes, C. M.
    Vernal, S.
    Leeflang, M. M. G.
    CLINICAL MICROBIOLOGY AND INFECTION, 2019, 25 (11) : 1315 - 1327
  • [38] Diagnostic accuracy for skin cancers: a systematic review and meta-analysis
    Chen, Jennifer
    Fernandez, Kristen
    Reddy, Rasika
    Fadadu, Raj
    Kohn, Michael
    Kim, Mi-Ok
    Wei, Maria
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2023, 89 (03) : AB148 - AB148
  • [39] Systematic review with meta-analysis of diagnostic test accuracy for COVID-19 by mass spectrometry
    Spick, Matt
    Lewis, Holly M.
    Wilde, Michael J.
    Hopley, Christopher
    Huggett, Jim
    Bailey, Melanie J.
    METABOLISM-CLINICAL AND EXPERIMENTAL, 2022, 126
  • [40] A simple plaster for screening for diabetic neuropathy: A diagnostic test accuracy systematic review and meta-analysis
    Tsapas, Apostolos
    Liakos, Aris
    Paschos, Paschalis
    Karagiannis, Thomas
    Bekiari, Eleni
    Tentolouris, Nikolaos
    Boura, Panagiota
    METABOLISM-CLINICAL AND EXPERIMENTAL, 2014, 63 (04): : 584 - 592