A super-voxel-based method for generating surrogate lung ventilation images from CT

被引:5
|
作者
Chen, Zhi [1 ]
Huang, Yu-Hua [1 ]
Kong, Feng-Ming [2 ,3 ]
Ho, Wai Yin [4 ]
Ren, Ge [1 ]
Cai, Jing [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Hlth Technol & Informat, Hong Kong, Peoples R China
[2] Queen Mary Hosp, Dept Clin Oncol, Hong Kong, Peoples R China
[3] Univ Hong Kong, Dept Clin Oncol, Hong Kong, Peoples R China
[4] Queen Mary Hosp, Dept Nucl Med, Hong Kong, Peoples R China
关键词
ventilation; 4DCT; super-voxel; radiotherapy; lung cancer; COMPUTED-TOMOGRAPHY; HYPERPOLARIZED HE-3; SPECT; VOLUME;
D O I
10.3389/fphys.2023.1085158
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Purpose: This study aimed to develop and evaluate CTVISVD, a super-voxel-based method for surrogate computed tomography ventilation imaging (CTVI). Methods and Materials: The study used four-dimensional CT (4DCT) and single-photon emission computed tomography (SPECT) images and corresponding lung masks from 21 patients with lung cancer obtained from the Ventilation And Medical Pulmonary Image Registration Evaluation dataset. The lung volume of the exhale CT for each patient was segmented into hundreds of super-voxels using the Simple Linear Iterative Clustering (SLIC) method. These super-voxel segments were applied to the CT and SPECT images to calculate the mean density values (D-mean) and mean ventilation values (Vent(mean)), respectively. The final CT-derived ventilation images were generated by interpolation from the Dmean values to yield CTVISVD. For the performance evaluation, the voxel- and region-wise differences between CTVISVD and SPECT were compared using Spearman's correlation and the Dice similarity coefficient index. Additionally, images were generated using two deformable image registration (DIR)-based methods, CTVIHU and CTVIJac, and compared with the SPECT images. Results: The correlation between the D-mean and Vent(mean) of the super-voxel was 0.59 +/- 0.09, representing a moderate-to-high correlation at the super-voxel level. In the voxel-wise evaluation, the CTVISVD method achieved a stronger average correlation (0.62 +/- 0.10) with SPECT, which was significantly better than the correlations achieved with the CTVIHU (0.33 +/- 0.14, p < 0.05) and CTVIJac (0.23 +/- 0.11, p < 0.05) methods. For the region-wise evaluation, the Dice similarity coefficient of the high functional region for CTVISVD (0.63 +/- 0.07) was significantly higher than the corresponding values for the CTVIHU (0.43 +/- 0.08, p < 0.05) and CTVIJac (0.42 +/- 0.05, p < 0.05) methods. Conclusion: The strong correlation between CTVISVD and SPECT demonstrates the potential usefulness of this novel method of ventilation estimation for surrogate ventilation imaging.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Method of automatic ROI selection on lung CT images
    Gaidel, Andrey
    3RD INTERNATIONAL CONFERENCE INFORMATION TECHNOLOGY AND NANOTECHNOLOGY (ITNT-2017), 2017, 201 : 258 - 264
  • [22] SIFT-GVF-based lung edge correction method for correcting the lung region in CT images
    Li, Xin
    Feng, Bin
    Qiao, Sai
    Wei, Haiyan
    Feng, Changli
    PLOS ONE, 2023, 18 (02):
  • [23] Voxel agglomeration for accelerated estimation of permeability from micro-CT images
    Chung, Traiwit
    Wang, Ying Da
    Armstrong, Ryan T.
    Mostaghimi, Peyman
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2020, 184 (184)
  • [24] Identification of Benign and Malignant Lung Nodules in CT Images Based on Ensemble Learning Method
    Xu, Yifei
    Wang, Shijie
    Sun, Xiaoqian
    Yang, Yanjun
    Fan, Jiaxing
    Jin, Wenwen
    Li, Yingyue
    Su, Fangchu
    Zhang, Weihua
    Cui, Qingli
    Hu, Yanhui
    Wang, Sheng
    Zhang, Jianhua
    Chen, Chuanliang
    INTERDISCIPLINARY SCIENCES-COMPUTATIONAL LIFE SCIENCES, 2022, 14 (01) : 130 - 140
  • [25] Identification of Benign and Malignant Lung Nodules in CT Images Based on Ensemble Learning Method
    Yifei Xu
    Shijie Wang
    Xiaoqian Sun
    Yanjun Yang
    Jiaxing Fan
    Wenwen Jin
    Yingyue Li
    Fangchu Su
    Weihua Zhang
    Qingli Cui
    Yanhui Hu
    Sheng Wang
    Jianhua Zhang
    Chuanliang Chen
    Interdisciplinary Sciences: Computational Life Sciences, 2022, 14 : 130 - 140
  • [26] Quantification of Lung Ventilation Using Voxel-Based Delta Radiomics Extracted from Thoracic 4DCT
    Chen, X.
    Lafata, K.
    Yang, Z.
    Yin, F.
    MEDICAL PHYSICS, 2020, 47 (06) : E435 - E435
  • [27] Generation of planar images from lung ventilation/perfusion SPECT
    Bailey, Dale L.
    Schembri, Geoffrey P.
    Harris, Benjamin E.
    Bailey, Elizabeth A.
    Cooper, Robert A.
    Roach, Paul J.
    ANNALS OF NUCLEAR MEDICINE, 2008, 22 (05) : 437 - 445
  • [28] Voxel-based comparative analysis of lung lesions in CT for therapeutic purposes
    Barros Netto, Stelmo Magalhaes
    Silva, Aristofanes Correa
    Nunes, Rodolfo Acatauassu
    Gattass, Marcelo
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2017, 55 (02) : 295 - 314
  • [29] Voxel-based comparative analysis of lung lesions in CT for therapeutic purposes
    Stelmo Magalhães Barros Netto
    Aristófanes Corrêa Silva
    Rodolfo Acatauassú Nunes
    Marcelo Gattass
    Medical & Biological Engineering & Computing, 2017, 55 : 295 - 314
  • [30] Generation of planar images from lung ventilation/perfusion SPECT
    Dale L. Bailey
    Geoffrey P. Schembri
    Benjamin E. Harris
    Elizabeth A. Bailey
    Robert A. Cooper
    Paul J. Roach
    Annals of Nuclear Medicine, 2008, 22