Titanium Boston keratoprosthesis with corneal cell adhesive and bactericidal dual coating

被引:3
|
作者
Gomez, Silvia Gonzalez [1 ,2 ,3 ]
Guillem-Marti, Jordi [1 ,2 ,3 ,7 ]
Martin-Gomez, Helena [1 ,2 ]
Mas-Moruno, Carlos [1 ,2 ,3 ]
Ginebra, Maria-Pau [1 ,2 ,3 ,4 ]
Gil, Francisco Javier [5 ]
Barraquer, Rafael Ignasi [6 ]
Manero, Jose Maria [1 ,2 ,3 ]
机构
[1] Univ Politecn Cataluna, Barcelona East Sch Engn EEBE, Dept Mat Sci & Engn, Biomat Biomech & Tissue Engn Grp, Barcelona 08019, Spain
[2] UPC, Barcelona Res Ctr Multiscale Sci & Engn, EEBE, Barcelona 08019, Spain
[3] Inst Recerca St Joan Deu, Barcelona 08034, Spain
[4] Inst Bioengn Catalonia IBEC, Barcelona 08028, Spain
[5] Univ Int Catalunya, Bioengn Inst Technol, Barcelona 08195, Spain
[6] Ctr Oftalmol Barraquer, Barcelona, Spain
[7] Univ Politecn Catalunya UPC, Dept Mat Sci & Engn, Biomat Biomech & Tissue Engn Grp, Barcelona, Spain
来源
BIOMATERIALS ADVANCES | 2023年 / 154卷
关键词
Boston keratoprostheses; Corneal blindness; Dual coating; Peptide platform; Titanium implant; GRAM-NEGATIVE BACTERIA; INFECTIOUS ENDOPHTHALMITIS; SURFACE-ROUGHNESS; III COLLAGEN; IN-VITRO; KERATOCYTE; DIFFERENTIATION; PROLIFERATION; MYOFIBROBLAST; BINDING;
D O I
10.1016/j.bioadv.2023.213654
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
The Boston keratoprosthesis (BKPro) is a medical device used to restore vision in complicated cases of corneal blindness. This device is composed by a front plate of polymethylmethacrylate (PMMA) and a backplate usually made of titanium (Ti). Ti is an excellent biomaterial with numerous applications, although there are not many studies that address its interaction with ocular cells. In this regard, despite the good retention rates of the BKPro, two main complications compromise patients' vision and the viability of the prosthesis: imperfect adhesion of the corneal tissue to the upside of the backplate and infections. Thus, in this work, two topographies (smooth and rough) were generated on Ti samples and tested with or without functionalization with a dual peptide platform. This molecule consists of a branched structure that links two peptide moieties to address the main complications associated with BKPro: the well-known RGD peptide in its cyclic version (cRGD) as cell pro-adherent motif and the first 11 residues of lactoferrin (LF1-11) as antibacterial motif. Samples were physicochemically characterized, and their biological response was evaluated in vitro with human corneal keratocytes (HCKs) and against the gram-negative bacterial strain Pseudomonas aeruginosa. The physicochemical characterization allowed to verify the functionalization in a qualitative and quantitative manner. A higher amount of peptide was anchored to the rough surfaces. The studies performed using HCKs showed increased long-term proliferation on the functionalized samples. Gene expression was affected by topography and peptide functionalization. Roughness promoted alpha-smooth muscle actin (alpha-SMA) overexpression, and the coating notably increased the expression of extracellular matrix components (ECM). Such changes may favour the development of unwanted fibrosis, and thus, corneal haze. In contrast, the combination of the coating with a rough topography decreased the expression of alpha-SMA and ECM components, which would be desirable for the long-term success of the prosthesis. Regarding the antibacterial activity, the functionalized smooth and rough surfaces promoted the death of bacteria, as well as a perturbation in their wall definition and cellular morphology. Bacterial killing values were 58 % for smooth functionalised and 68 % for rough functionalised samples. In summary, this study suggests that the use of the dual peptide platform with cRGD and LF1-11 could be a good strategy to improve the in vitro and in vivo performance of the rough topography used in the commercial BKPro.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Outcomes of the Boston Type I Keratoprosthesis as the Primary Penetrating Corneal Procedure
    Driver, Todd H.
    Aravena, Carolina
    Duong, Huong N. V.
    Christenbury, Joseph G.
    Yu, Fei
    Basak, Samar K.
    Aldave, Anthony J.
    CORNEA, 2018, 37 (11) : 1400 - 1407
  • [22] An improved biofunction of Titanium for keratoprosthesis by hydroxyapatite-coating
    Dong, Ying
    Yang, Jingxin
    Wang, Liqiang
    Ma, Xiao
    Huang, Yifei
    Qiu, Zhiye
    Cui, Fuzhai
    JOURNAL OF BIOMATERIALS APPLICATIONS, 2014, 28 (07) : 990 - 997
  • [23] The Use of Precut, γ-Irradiated Corneal Lenticules in Boston Type 1 Keratoprosthesis Implantation
    Akpek, Esen K.
    Aldave, Anthony J.
    Aquavella, James V.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 154 (03) : 495 - 498
  • [24] Boston Type 1 Keratoprosthesis for Gelatinous Drop-Like Corneal Dystrophy
    Lekhanont, Kaevalin
    Jongkhajornpong, Passara
    Chuephanich, Pichaya
    Inatomi, Tsutomu
    Kinoshita, Shigeru
    OPTOMETRY AND VISION SCIENCE, 2016, 93 (06) : 640 - 646
  • [25] Long-Term Outcomes of the Boston Type I Keratoprosthesis in the Management of Corneal Limbal Stem Cell Deficiency
    Aravena, Carolina
    Bozkurt, Tahir Kansu
    Yu, Fei
    Aldave, Anthony J.
    CORNEA, 2016, 35 (09) : 1156 - 1164
  • [26] In Situ Corneal Cross-Linking for Recurrent Corneal Melting After Boston Type 1 Keratoprosthesis
    Toth, Gabor
    Bucher, Franziska
    Siebelmann, Sebastian
    Bachmann, Bjoern
    Hermann, Manuel
    Szentmary, Nora
    Nagy, Zoltan Zsolt
    Cursiefen, Claus
    CORNEA, 2016, 35 (06) : 884 - 887
  • [27] In Vitro and In Vivo Assessment of Titanium Surface Modification for Coloring the Backplate of the Boston Keratoprosthesis
    Paschalis, Eleftherios I.
    Chodosh, James
    Spurr-Michaud, Sandra
    Cruzat, Andrea
    Tauber, Allyson
    Behlau, Irmgard
    Gipson, Ilene
    Dohlman, Claes H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (06) : 3863 - 3873
  • [28] Boston keratoprosthesis type 1 for limbal stem cell deficiency after severe chemical corneal injury: A systematic review
    Shanbhag, Swapna S.
    Saeed, Hajirah N.
    Paschalis, Eleftherios I.
    Chodosh, James
    OCULAR SURFACE, 2018, 16 (03): : 272 - 281
  • [29] Repair of an exposed glaucoma tube with a corneal graft in a patient with a Boston type 1 keratoprosthesis
    Oydanich, M.
    Khouri, A. S.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2024, 47 (02):
  • [30] Management of corneal melt in patients with Boston Keratoprosthesis Type 1: Repair versus repeat
    Daoud, Roy
    Sabeti, Saama
    Harissi-Dagher, Mona
    OCULAR SURFACE, 2020, 18 (04): : 713 - 717