Rapid Building Energy Modeling Using Prototype Model and Automatic Model Calibration for Retrofit Analysis with Uncertainty

被引:4
|
作者
Chen, Yixing [1 ,2 ]
Wei, Wanlei [1 ]
Song, Chengcheng [1 ]
Ren, Zhiyi [1 ]
Deng, Zhang [1 ]
机构
[1] Hunan Univ, Coll Civil Engn, Changsha 410082, Peoples R China
[2] Hunan Univ, Key Lab Bldg Safety & Energy Efficiency, Minist Educ, Changsha 410082, Peoples R China
关键词
AutoBPS; shopping mall; model calibration; EnergyPlus; Monte Carlo; uncertainty analysis; CONSUMPTION; SIMULATION; STORAGE; SYSTEMS; CHINA;
D O I
10.3390/buildings13061427
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Building performance simulation can be used for retrofit analysis. However, it is time-consuming to create building energy models for existing buildings. This paper presented and implemented a rapid building energy modeling method for existing buildings by using prototype models and automatic model calibration for retrofit analysis with uncertainty. A shopping mall building located in Changsha, China, was selected as a case study to demonstrate the rapid modeling method. First, a toolkit named AutoBPS-Param was developed to generate building energy models with parameterized geometry data. A baseline EnergyPlus model was generated based on the building's basic information, including vintage, climate zone, total floor area, and percentage of each function type. Next, Monte Carlo sampling was applied to generate 1000 combinations for fourteen parameters. One thousand EnergyPlus models were created by modifying the baseline model with each parameter combination. Moreover, the 1000 simulation results were compared with the measured monthly electricity and natural gas usage data to find 29 calibrated solutions. Finally, the 29 calibrated energy models were used to evaluate the energy-saving potential of three energy conservation measures with uncertainty. The retrofit analysis results indicated that the electrical energy saving percentage of chiller replacement ranged from 1.57% to 13.51%, with an average of 8.27%. The energy-saving rate of lighting system replacement ranged from 1.92% to 11.66%, with an average of 6.43%. The energy-saving rate of window replacement ranges from 0.31% to 1.81%, with an average of 0.55%. The results showed that AutoBPS-Param could rapidly create building energy models for existing buildings and can be used for retrofit analysis after model calibration.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] Calibration of building energy models for retrofit analysis under uncertainty
    Heo, Y.
    Choudhary, R.
    Augenbroe, G. A.
    ENERGY AND BUILDINGS, 2012, 47 : 550 - 560
  • [2] Leveraging the analysis of parametric uncertainty for building energy model calibration
    O'Neill, Zheng
    Eisenhower, Bryan
    BUILDING SIMULATION, 2013, 6 (04) : 365 - 377
  • [3] Leveraging the analysis of parametric uncertainty for building energy model calibration
    Zheng O’Neill
    Bryan Eisenhower
    Building Simulation, 2013, 6 : 365 - 377
  • [4] Impact of measured data frequency on commercial building energy model calibration for retrofit analysis
    Derakhti, Mohammad
    O'Brien, William
    Bucking, Scott
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2022, 28 (05) : 628 - 644
  • [5] Automatic calibration model of a building energy simulation using optimization algorithm
    Hong, Taehoon
    Kim, Jimin
    Jeong, Jaemin
    Lee, Myeonghwi
    Ji, Changyoon
    8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105 : 3698 - 3704
  • [6] Building Energy Simulation For Nearly Zero Energy Retrofit Design: The Model Calibration
    Angelotti, Adriana
    Martire, Maricla
    Mazzarella, Livio
    Pasini, Martina
    Ballarini, Ilaria
    Corrado, Vincenzo
    De Luca, Giovanna
    Baggio, Paolo
    Prada, Alessandro
    Bosco, Francesco
    Cornaro, Cristina
    2018 IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2018 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2018,
  • [7] Calibration of a Building Energy Model Considering Parametric Uncertainty
    O'Neill, Zheng
    Eisenhower, Bryan
    Fonoberov, Vladimir
    Bailey, Trevor
    ASHRAE TRANSACTIONS 2012, VOL 118, PT 2, 2012, 118 : 189 - 196
  • [8] Hybrid building energy modeling method with parameterized prototype models and rapid calibration
    Li, Guangchen
    Yang, Jingjing
    Guo, Jiapeng
    Wang, Zhiyuan
    Deng, Zhang
    Chen, Jianli
    Chen, Yixing
    Energy and Buildings, 2024, 325
  • [9] Sensitivity Analysis for Building Energy Simulation Model Calibration via Automatic Differentiation
    Li, Sisi
    Zhou, MengChu
    Deng, Kun
    Song, Zhen
    Lu, Yan
    2014 IEEE 11TH INTERNATIONAL CONFERENCE ON NETWORKING, SENSING AND CONTROL (ICNSC), 2014, : 607 - 612
  • [10] Developing a model for energy retrofit in large building portfolios: Energy assessment, optimization and uncertainty
    Gabrielli, Laura
    Ruggeri, Aurora Greta
    ENERGY AND BUILDINGS, 2019, 202