关键词
chitosan; hydrogel coating; inflammation; suture degradation; suture treatment; SYNOVIAL-FLUID; ACIDOSIS; TENDON;
D O I
10.1002/jor.25514
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The mechanical properties of sutures are important for wound closure and meniscus repair. A tough gel coating technology has been developed to modify and functionalize sutures, but its effects on suture degradation remain unexplored. Our aim is to investigate how a tough gel coating mediates the properties of the suture. The Polyglactin910 (Vicryl) suture was chosen because it is widely used, strong, easy to handle, and degradable. This study compared six pristine Vicryl sutures and six coated Vicryl sutures at 0, 2, 4, and 6 weeks. All the sutures were soaked in phosphate-buffered saline (PBS), to mimic degradation in physiological conditions, and tensile strength was tested at each time point. The pH of the soaking mediums was measured weekly and compared at 4, 5, and 6 weeks. No significant difference (p = 0.059 and p = 0.576) was found between the absolute and normalized breaking force of coated and pristine Vicryl sutures at 0, 2, 4, and 6 weeks. After 4 weeks of immersion, the soaking medium became more acidic for both suture types. The decrease in pH was less significant for coated Vicryl sutures than for pristine ones (p < 0.001) at 4, 5, and 6 weeks of immersion. Although coating does not affect the strength of Vicryl sutures soaked in PBS, it can effectively act as a buffer to the acidic environment caused by suture degradation, which could help reduce inflammation. Hydrogel coating is a promising technology to modify suture characteristics.
引用
收藏
页码:1815 / 1820
页数:6
相关论文
共 50 条
  • [21] Micromechanical poroelastic and viscoelastic properties of ex-vivo soft tissues
    Islam, Mohammad R.
    Virag, Jitka
    Oyen, Michelle L.
    JOURNAL OF BIOMECHANICS, 2020, 113
  • [22] EX-VIVO OPTICAL-PROPERTIES OF HUMAN COLON TISSUE
    MARCHESINI, R
    PIGNOLI, E
    TOMATIS, S
    FUMAGALLI, S
    SICHIROLLO, AE
    DIPALMA, S
    DALFANTE, M
    SPINELLI, P
    CROCE, AC
    BOTTIROLI, G
    LASERS IN SURGERY AND MEDICINE, 1994, 15 (04) : 351 - 357
  • [23] Comparison of two techniques (in vivo and ex-vivo) for evaluating the elastic properties of the ascending aorta: Prospective cohort study
    Morgant, Marie-Catherine
    Lin, Siyu
    Marin-Castrillon, Diana
    Bernard, Chloe
    Laubriet, Aline
    Cochet, Alexandre
    Lalande, Alain
    Bouchot, Olivier
    PLOS ONE, 2021, 16 (09):
  • [24] Development and Optimization of Proniosomal Gel Containing Etodolac: In-vitro, Ex-vivo and In-vivo Evaluation
    Patil, Moreshwar
    Pandit, Prashant
    Udavant, Pavan
    Sonawane, Sandeep
    Bhambere, Deepak
    ARS PHARMACEUTICA, 2021, 62 (03) : 290 - 304
  • [25] Corneal lenticules as an ex-vivo model to study keratocyte biology
    Shroff, R.
    Shetty, R.
    Kumar, D.
    Kumar, S.
    Pahuja, N.
    Ghosh, A.
    ACTA OPHTHALMOLOGICA, 2015, 93
  • [26] A TECHNIQUE FOR THE EX-VIVO STUDY OF ENDOTHELIAL-SECRETED VWF
    OBRIEN, JR
    THROMBOSIS AND HAEMOSTASIS, 1993, 69 (06) : 949 - 949
  • [27] Argatroban for anticoagulation of a blood salvage system - an ex-vivo study
    Martin Beiderlinden
    Carsten Brau
    Santo di Grazia
    Michael Wehmeier
    Tanja A. Treschan
    BMC Anesthesiology, 16
  • [28] Mucoadhesive polymer films for tissue retraction in laparoscopic surgery: Ex-vivo study on their mechanical properties
    Wang, Zhigang
    Tai, Lik-Ren
    McLean, Donald
    Wright, Emma J.
    Florence, Gordon J.
    Brown, Stuart I.
    Andre, Pascal
    Cuschieri, Alfred
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (01) : 445 - 451
  • [29] Novel stent surface coating inhibits thrombus formation in a baboon ex-vivo model
    Jabara, R.
    Robinson, K.
    Gadesam, R.
    Pendyala, L.
    Chronos, N.
    Hanson, S.
    EUROPEAN HEART JOURNAL, 2009, 30 : 759 - 759
  • [30] Development of an Ex-vivo Model to Study Tissue Contraction in the Conjunctiva
    Tovell, V. E.
    Khaw, P. T.
    Bailly, M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)