Acceptable indoor air quality at reduced energy consumption for high-occupancy buildings with intermittent operation

被引:3
|
作者
Budaiwi, Ismail Mohammed [1 ]
Mohammed, Mohammed Alhaji [1 ]
机构
[1] King Fahd Univ Petr & Minerals, Coll Environm Design, Dept Architectural Engn, Dhahran, Saudi Arabia
关键词
High occupancy buildings; ventilation; indoor air quality; energy savings; intermittent occupancy; contaminant; OPTIMAL TEMPERATURE CONTROL; THERMAL COMFORT; PERSONALIZED VENTILATION; OFFICE BUILDINGS; SUPPLY-SYSTEM; FLOW; PERFORMANCE; VALIDATION; PERCEPTION; MODEL;
D O I
10.1080/00038628.2023.2199705
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In high-occupancy buildings with intermittent and short-occupancy events, occupants and their activities are the primary sources of contaminants, rendering continuous ventilation unnecessary for achieving acceptable indoor air quality (IAQ). Because the recommended ventilation rate constitutes a substantial percentage of the supply air, reducing or discontinuing ventilation during unoccupied periods saves significant energy. This study aims to assess the IAQ of high-occupancy buildings with different ventilation strategies and occupancy schemes to conserve energy using CONTAM (IAQ and ventilation analysis program) and Visual-DOE (energy analysis program). The results show that intermittently operating the ventilation 1 hour before occupancy saves 25% in the auditorium and 33% in the mosque compared to the continuous ventilation strategy. The intermittently operated strategy with ventilation 1 hour before occupancy also revealed an acceptable CO2 level (<1000ppm), while the Formaldehyde (HCHO) levels decreased with increasing ventilation rates, as humans' contribution to the HCHO concentration indoors was insignificant.
引用
收藏
页码:242 / 258
页数:17
相关论文
共 50 条
  • [31] Ventilation Control Approach for Acceptable Indoor Air Quality and Enhancing Energy Saving In Thailand
    Boonyayothin, Vorakamol
    Hirunlabh, Jongjit
    Khummongkol, Pojanie
    Teekasap, Sombat
    Shin, U-Cheul
    Khedari, Joseph
    INTERNATIONAL JOURNAL OF VENTILATION, 2011, 9 (04) : 315 - 326
  • [32] Indoor air quality control in case of scheduled or intermittent occupancy based building: Development of a scale model
    El Mankibi, Mohamed
    BUILDING AND ENVIRONMENT, 2009, 44 (07) : 1356 - 1361
  • [33] Comparison of strategies to improve indoor air quality at pre-occupancy stage in new apartment buildings
    Kim, SS
    Kang, DH
    Choi, DH
    Yeo, MS
    Kim, KW
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 633 - 637
  • [34] Microbiological indoor air quality of hospital buildings with different ventilation systems, cleaning frequencies and occupancy levels
    Hassan, Ahmad
    Zeeshan, Muhammad
    ATMOSPHERIC POLLUTION RESEARCH, 2022, 13 (04)
  • [35] Improving the Indoor Air Quality of Office Buildings in the Post-Pandemic Era-Impact on Energy Consumption and Costs
    D'Agostino, Diana
    Minelli, Federico
    Minichiello, Francesco
    Musella, Maddalena
    ENERGIES, 2024, 17 (04)
  • [36] Comparison of strategies to improve indoor air quality at the pre-occupancy stage in new apartment buildings
    Kim, Sun-Sook
    Kang, Dong-Hwa
    Choi, Dong-Hee
    Yeo, Myoung-Souk
    Kim, Kwang-Woo
    BUILDING AND ENVIRONMENT, 2008, 43 (03) : 320 - 328
  • [37] Intermittent demand-controlled ventilation for energy flexibility and indoor air quality
    Niu, Dun
    Li, Yuxin
    Zhang, Sheng
    Lin, Zhang
    BUILDING AND ENVIRONMENT, 2024, 263
  • [38] HOW VENTILATION INFLUENCES ENERGY CONSUMPTION AND INDOOR AIR QUALITY.
    Woods, James E.
    Maldonado, Eduardo A.B.
    Reynolds, Gary L.
    ASHRAE Journal, 1981, 23 (09) : 40 - 43
  • [39] A review on thermal comfort, indoor air quality and energy consumption in temples
    Yuksel, Ahmet
    Arici, Muslum
    Krajcik, Michal
    Civan, Mihriban
    Karabay, Hasan
    JOURNAL OF BUILDING ENGINEERING, 2021, 35
  • [40] Effectiveness of intermittent personalized ventilation assisting a chilled ceiling for enhanced thermal comfort and acceptable indoor air quality
    Al Assaad, Douaa
    Ghali, Kamel
    Ghaddar, Nesreen
    BUILDING AND ENVIRONMENT, 2018, 144 : 9 - 22