Exergy analysis and optimization of a hybrid cryocooler operating in 1-2 K based on the two-stage Joule-Thomson expansion

被引:1
|
作者
Zhao, Bangjian [1 ,3 ]
Tan, Jun [1 ,4 ]
Zhao, Yongjiang [1 ,3 ]
Xue, Renjun [1 ,3 ]
Tan, Han [1 ,3 ]
Wu, Shiguang [1 ,3 ]
Zhai, Yujia [1 ,3 ]
Wu, Dirui [1 ,3 ]
Ma, Dong [1 ,3 ]
Dang, Haizheng [1 ,2 ,4 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Tech Phys, State Key Lab Infrared Phys, 500 Yutian Rd, Shanghai 200083, Peoples R China
[2] Shanghai Res Ctr Quantum Sci, Shanghai 201315, Peoples R China
[3] Univ Chinese Acad Sci, 19A Yuquan Rd, Beijing 100049, Peoples R China
[4] Shanghai Boreas Cryogen Co Ltd, Shanghai 201802, Peoples R China
基金
中国国家自然科学基金;
关键词
Exergy analysis; Optimization; Hybrid cryocooler; Two-stage JT expansion; 1-2; K; HEAT-TRANSFER; REFRIGERATION; TUBE;
D O I
10.1016/j.energy.2023.128314
中图分类号
O414.1 [热力学];
学科分类号
摘要
Theoretical and experimental investigations on a hybrid cryocooler with the two-stage Joule-Thomson (JT) expansion operating in 1-2 K are conducted. An exergy model is carried out to analyze the irreversibility of each component and to determine the maximum exergy efficiency of the JT cycle which provides the direction for potential improvements. Important operating parameters are calculated to evaluate the exergy destructions of the components as well as the whole system. The simulation results show that the JT cycle with two-stage expansion processes has higher energy and exergy performances than the single-stage system. The experimental results indicate that with two-stage JT expansion the hybrid cryocooler achieves the cooling capacity of 56.2 mW at 2.0 K with a gross input power of 398 W, the FOM is improved from 1.54% to 1.93%, and the exergy efficiency of the JT cycle is enhanced to 48.93% from 29.77% with the single-stage JT expansion. The good agreements between simulations and experiments are observed.
引用
收藏
页数:14
相关论文
共 23 条
  • [21] Modeling and performance analysis of a hybrid-connected two-stage liquid dehumidification fresh air system based on CaCl2/LiCl double solution
    Peng, Donggen
    Cao, Zhuo
    Applied Thermal Engineering, 2021, 199
  • [22] Modeling and performance analysis of a hybrid-connected two-stage liquid dehumidification fresh air system based on CaCl2/LiCl double solution
    Peng, Donggen
    Cao, Zhuo
    APPLIED THERMAL ENGINEERING, 2021, 199
  • [23] Energy optimization dispatch based on two-stage and multi-objective comparative analysis for PV and BESS integrated fast charging stations with V2G
    Zhan, Shuhe
    Zhou, Yun
    Feng, Donghan
    Wang, Haojing
    Fang, Chen
    IET RENEWABLE POWER GENERATION, 2024, 18 : 4426 - 4438