Effect of stagnation period and flow rate on soluble and particulate Pb leaching in copper pipe water distribution systems

被引:0
|
作者
Chang, Lu [1 ]
Lee, Joseph H. W. [2 ]
机构
[1] Beijing Normal Univ, Sch Environm, State Key Lab Water Environm Simulat, Beijing 100875, Peoples R China
[2] Macau Univ Sci & Technol, Macao Environm Res Inst, Taipa, Macao, Peoples R China
关键词
Lead in drinking water; Copper water distribution system; Particulates contaminants; Sequential sampling; Stagnation time; Flow rate; DRINKING-WATER; LEAD RELEASE; CORROSION; EXPOSURE; BUILDINGS; PARTICLES; CHEMISTRY;
D O I
10.1016/j.jher.2023.06.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Extremely high lead level in tap water caused by particulates has attracted increasing attention in recent years. Despite extensive research on the role of particulate Pb in water supply systems with lead service lines, little information is available on the role of particulate Pb in copper (Cu) water distribution systems. In this study, the dissolved, colloidal, and particulate lead and copper concentrations in representative prototype copper pipe water distribution systems with leaded solder joints and brass fixtures are measured. The effects of flow rate and stagnation time on metal fractionation are investigated. For each experimental scenario, all the water that stagnated inside the system is sampled to have a comprehensive understanding of lead contamination. Sampled at flow rates of 200-250 mL/s, the soluble lead and copper make up 60-96 % of the total concentration in the samples after hours of stagnation. More than half of the Pb and Cu particles are larger than 0.8 & mu;m. Higher flow rates result in substantial increases in particulate metal concentrations but have no apparent effect on dissolved metals. The soluble and particulate copper concentrations (. 100-250 & mu;g/L) both increase with stagnation time. For the case of Pb, while the particulate concentration increases (up to . 40 & mu;g/L after 12 h), the soluble concentration does not change significantly beyond 4 h; this can be attributed to the different solubilities of Pb (. 20 & mu;g/L) and Cu (. 200 & mu;g/L) in tap water. The results also show that particulates suspended by clean "once through" water (without prior stagnation) can lead to high levels of Pb contamination (> 10 & mu;g/L).
引用
收藏
页码:1 / 9
页数:9
相关论文
共 39 条
  • [21] A Novel Leakage-Detection Method Based on Sensitivity Matrix of Pipe Flow: Case Study of Water Distribution Systems
    Geng, Zhiqiang
    Hu, Xuan
    Han, Yongming
    Zhong, Yanhua
    JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT, 2019, 145 (02)
  • [22] Unsteady stagnation-point flow and heat transfer over an exponential stretching sheet in Copper-water nanofluid with slip velocity effect
    Dzulkifli, N. F.
    Bachok, N.
    Pop, I.
    Yacob, N. A.
    Arifin, N. M.
    Rosali, H.
    3RD INTERNATIONAL CONFERENCE ON MATHEMATICAL SCIENCES AND STATISTICS, 2018, 1132
  • [23] THE EFFECT OF PH ADJUSTMENT ON THE INTERNAL CORROSION RATE OF RESIDENTIAL CAST-IRON AND COPPER WATER DISTRIBUTION PIPES
    MILLETTE, L
    MAVINIC, DS
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1988, 15 (01) : 79 - 90
  • [24] Effect of pipe materials on chlorine decay, trihalomethanes formation, and bacterial communities in pilot-scale water distribution systems
    C. Zhang
    C. Li
    X. Zheng
    J. Zhao
    G. He
    T. Zhang
    International Journal of Environmental Science and Technology, 2017, 14 : 85 - 94
  • [25] Effect of pipe materials on chlorine decay, trihalomethanes formation, and bacterial communities in pilot-scale water distribution systems
    Zhang, C.
    Li, C.
    Zheng, X.
    Zhao, J.
    He, G.
    Zhang, T.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2017, 14 (01) : 85 - 94
  • [26] EFFECT OF WATER FLOW RATE ON COOLING EFFECTIVENESS AND AIR TEMPERATURE CHANGE IN EVAPORATIVE COOLING PAD SYSTEMS
    Karaca, Cengiz
    Yildiz, Yilmaz
    Dagtekin, Metin
    Gumus, Zekai
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2016, 15 (04): : 827 - 833
  • [28] Water spray flow rate effect on smoke temperature distribution under the ceiling in tunnel fires with longitudinal ventilation
    Wang, Jie
    Xie, Zhicheng
    Lu, Kaihua
    Jiang, Xuepeng
    Zhang, Hongjie
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2018, 79 : 190 - 196
  • [29] The effect of white or grey PVC pipe and its joint solvents (primer and cement) on odour problems CD in drinking water distribution systems
    Wiesenthal, K. E.
    Suffet, I. H.
    WATER SCIENCE AND TECHNOLOGY, 2007, 55 (05) : 169 - 176
  • [30] Enhancing heat pipe solar water heating systems performance using a novel variable mass flow rate technique and different solar working fluids
    Shafieian, Abdellah
    Osman, Junaid Jaffer
    Khiadani, Mehdi
    Nosrati, Ataollah
    SOLAR ENERGY, 2019, 186 : 191 - 203