Quantitative assessment of corneal elasticity distribution after FS-LASIK using optical coherence elastography

被引:4
|
作者
Han, Xiao [1 ,2 ,3 ]
Zhang, Yubao [2 ,3 ]
Shi, Gang [4 ]
Liu, Guo [2 ,3 ]
Ai, Sizhu [2 ,3 ]
Wang, Yidi [1 ,2 ,3 ]
Zhang, Qin [2 ,3 ]
He, Xingdao [1 ,2 ,3 ]
机构
[1] Beihang Univ, Sch Instrument Sci & Optoelect Engn, Beijing, Peoples R China
[2] Nanchang Hangkong Univ, Key Lab Optoelect Informat Sci & Technol Jiangxi P, Nanchang, Peoples R China
[3] Nanchang Hangkong Univ, Jiangxi Engn Lab Optoelect Testing Technol, Nanchang, Peoples R China
[4] Univ Sci & Technol Beijing, Sch Math & Phys, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
corneal elasticity distribution; FS-LASIK; optical coherence elastography; Young's modulus; BIOMECHANICAL PROPERTIES; SHEAR-WAVE; EX-VIVO; PRINCIPLES;
D O I
10.1002/jbio.202300441
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Quantifying corneal elasticity after femtosecond laser-assisted in situ keratomileusis (FS-LASIK) procedure plays an important role in improving surgical safety and quality, since some latent complications may occur ascribing to changes in postoperative corneal biomechanics. Nevertheless, it is suggested that current research has been severely constrained due to the lack of an accurate quantification method to obtain postoperative corneal elasticity distribution. In this paper, an acoustic radiation force optical coherence elastography system combined with the improved phase velocity algorithm was utilized to realize elasticity distribution images of the in vivo rabbit cornea after FS-LASIK under various intraocular pressure levels. As a result, elasticity variations within and between the regions of interest could be identified precisely. This is the first time that elasticity imaging of in vivo cornea after FS-LASIK surgery was demonstrated, and the results suggested that this technology may hold promise in further exploring corneal biomechanical properties after refractive surgery.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Changes in Corneal Volume at Different Areas and Its Correlation with Corneal Biomechanics after SMILE and FS-LASIK Surgery
    Wei, Pinghui
    Cheng, George P. M.
    Zhang, Jiamei
    Ng, Alex L. K.
    Chan, Tommy C. Y.
    Jhanji, Vishal
    Wang, Yan
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [22] Effects of corneal epithelial remodeling on corneal asphericity after FS-LASIK and Trans-PRK: A prospective study
    Xu, Mingyu
    Yang, Fan
    Pazo, Emmanuel Eric
    Li, Qiwei
    Yang, Zheng
    Huang, Yue
    Zhao, Shaozhen
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2025, 73 (01) : 134 - 140
  • [23] Comparison of Changes in Corneal Thickness and Curvature After Myopia Correction Between SMILE and FS-LASIK
    Kim, Bu Ki
    Chung, Young Taek
    JOURNAL OF REFRACTIVE SURGERY, 2023, : 15 - 22
  • [24] Changes of corneal epithelial thickness in different regions after FS-LASIK in high astigmatism patients
    Hu, Liang
    Liu, Zhi Chao
    Lin, Meng
    Lu, Fan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [25] Quantitative Compression Optical Coherence Elastography as an Inverse Elasticity Problem
    Dong, Li
    Wijesinghe, Philip
    Dantuono, James T.
    Sampson, David D.
    Munro, Peter R. T.
    Kennedy, Brendan F.
    Oberai, Assad A.
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2016, 22 (03) : 277 - 287
  • [26] Quantitative assessment of corneal viscoelasticity using elastic wave optic coherence elastography
    Wang, Yuanyuan
    Jin, Zi
    Chen, Sisi
    Zhu, Dexi
    Shen, Meixiao
    Lu, Fan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [27] To Investigate the Changes in Corneal Curvature and Its Correlation with Corneal Epithelial Remodeling After Trans-PRK and FS-LASIK
    Yang, Fan
    Yang, Zheng
    Zhao, Shaozhen
    Huang, Yue
    CURRENT EYE RESEARCH, 2024, 49 (10) : 1061 - 1067
  • [28] Corneal Biomechanical Properties after FS-LASIK with Residual Bed Thickness Less Than 50% of the Original Corneal Thickness
    Zhang, Haixia
    Khan, Muhammad Ahmad
    Zhang, Di
    Qin, Xiao
    Lin, Ding
    Li, Lin
    JOURNAL OF OPHTHALMOLOGY, 2018, 2018
  • [29] Comparison of posterior corneal elevation after SMILE and FS-LASIK in correcting myopia over?9.0 diopters
    Zhao, Yu
    Qian, Yishan
    Chen, Xun
    Zhou, Xueyi
    Qin, Bing
    Zhou, Xingtao
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (05)
  • [30] Dynamic and quantitative assessment of blood coagulation using optical coherence elastography
    Xu, Xiangqun
    Zhu, Jiang
    Chen, Zhongping
    SCIENTIFIC REPORTS, 2016, 6