Clinical value of four-dimensional hysterosalpingo-contrast sonography assisted by intrauterine pressure measurement for tubal patency evaluation

被引:0
|
作者
Lin, Chunhong [1 ]
Chen, Jianyong [2 ]
Li, Xianguo [3 ]
Wang, Linlin [1 ]
Yan, Fengqin [1 ]
Chang, Ye [4 ]
Yang, Xueniu [5 ,6 ]
机构
[1] Hengshui Peoples Hosp, Dept Ultrasound 3, Hengshui, Hebei, Peoples R China
[2] Hubei Coll Chinese Med, Dept Med Med, Jingzhou, Hubei, Peoples R China
[3] Fifth Peoples Hosp Hengshui, Med Dept, Hengshui, Hebei, Peoples R China
[4] Hengshui Peoples Hosp, Dept Ultrasound 1, Hengshui, Hebei, Peoples R China
[5] Chongqing Populat & Family Planning Sci & Technol, NHC Key Lab Birth Defects & Reprod Hlth, Chongqing, Peoples R China
[6] Chongqing Populat & Family Planning Sci & Technol, Chongqing Key Lab Birth Defects & Reprod Hlth, NHC Key Lab Birth Defects & Reprod Hlth, Chongqing, Peoples R China
来源
INVESTIGACION CLINICA | 2023年 / 64卷 / 03期
关键词
tubal patency; 4D hysterosalpingo-contrast sonography; intrauterine pressure;
D O I
10.54817/IC.v64n3a5
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
We aimed to explore the clinical value of four-dimensional hys-terosalpingo-contrast sonography (4D-HyCoSy) assisted by intrauterine pres-sure measurement for evaluating tubal patency. One hundred and thirty-two patients diagnosed with tubal factor infertility from February 2018 to February 2021 were selected as subjects. With hysterosalpingography diagnosis results as the gold standard, 4D-HyCoSy was conducted for all patients, and the status of the fallopian tubes was classified into patency, occlusion, and partial occlusion. Based on the function of fallopian tubes, 4D-HyCoSy diagnosis results revealed that fallopian tubes showed bilateral patency, incomplete patency (including bilateral partial occlusion, unilateral patency, and unilateral partial occlusion, unilateral patency and unilateral occlusion), unilateral partial occlusion and unilateral occlusion, and bilateral occlusion. The cutoff value of peak intra-uterine pressure was determined using the receiver operating characteristic curve (ROC), specificity, and the area under the ROC curve (AUC) between 4D-HyCoSy alone and 4D-HyCoSy assisted by intrauterine pressure measure-ments. There were significant differences in the peak intrauterine pressure among patients with bilateral patency, incomplete patency, unilateral partial occlusion, and unilateral and bilateral occlusions (p<0.05). The corresponding cutoff values of peak intrauterine pressure were 24.42, 36.34, and 47.68 kPa; AUC values were 0.812, 0.836, and 0.827, respectively. The FSM model showed that the AUC of 4D-HyCoSy alone, assisted by peak intrauterine pressure was 0.85, with a higher sensitivity (88.13%) than that of 4D-HyCoSy (p<0.05). 4D-HyCoSy, assisted by intrauterine pressure measurement, has an excellent value for evaluating tubal patency.
引用
收藏
页码:317 / 328
页数:12
相关论文
共 50 条
  • [21] The validity of air and saline hysterosalpingo-contrast sonography in tubal patency investigation before insemination treatment
    Ahinko-Hakamaa, Katja
    Huhtala, Heini
    Tinkanen, Helena
    EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2007, 132 (01): : 83 - 87
  • [22] Causes of misdiagnosis in assessing tubal patency by transvaginal real-time three-dimensional hysterosalpingo-contrast sonography
    Liang, Na
    Wu, Qing-Qing
    Li, Jing-Hua
    Gao, Feng-Yun
    Sun, Fu-Li
    Guo, Cui-Xia
    REVISTA DA ASSOCIACAO MEDICA BRASILEIRA, 2019, 65 (08): : 1055 - 1060
  • [23] Combined Real-Time Three-Dimensional Hysterosalpingo-Contrast Sonography with B Mode Hysterosalpingo-Contrast Sonography in the Evaluation of Fallopian Tube Patency in Patients Undergoing Infertility Investigations
    Chen, Sumin
    Du, Xiya
    Chen, Qingzi
    Chen, Shaoqi
    BIOMED RESEARCH INTERNATIONAL, 2019, 2019
  • [24] Use of atropine in four-dimensional hysterosalpingo-contrast sonography: Does it suppress pain during infertility examination?
    Ma, Yunfei
    Du, Lianfang
    Li, Fan
    Zhu, Zhengqiu
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 2018, 45 (12): : 1334 - 1340
  • [25] Hysterosalpingo-Contrast Sonography With a Saline-Air Device Is Equivalent to Hysterosalpingography Only in the Presence of Tubal Patency
    Robertshaw, Isela M.
    Sroga, Julie M.
    Batcheller, April E.
    Martinez, Alan M.
    Winter, Thomas C., III
    Sinning, Kristin
    Maxwell, Rose
    Lindheim, Steven R.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (06) : 1215 - 1222
  • [26] The value of transvaginal 4-dimensional hysterosalpingo-contrast sonography in predicting the necessity of assisted reproductive technology for women with tubal factor infertility
    Gu, Pan
    Yang, Xuan
    Zhao, Xingping
    Xu, Dabao
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (08) : 3698 - 3714
  • [27] Three- or four-dimensional hysterosalpingo contrast sonography for diagnosing tubal patency in infertile females: a systematic review with meta-analysis
    Wang, Yuelong
    Qian, Linxue
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1063):
  • [28] Intrauterine insemination results are not affected if Hysterosalpingo Contrast Sonography is used as the sole test of tubal patency
    Hamilton, J
    Latarche, E
    Gillott, C
    Lower, A
    Grudzinskas, JG
    FERTILITY AND STERILITY, 2003, 80 (01) : 165 - 171
  • [29] Four-dimensional hysterosalpingo-contrast sonography with auxiliary hydrogen peroxide examination for the diagnosis of fallopian tube patency following interventional treatment of ovarian ectopic cysts
    Dejiao Kong
    Xiaoqiu Dong
    Zihan Wang
    Liwei Zhang
    Xiaohui Shao
    Yunfeng Qi
    Archives of Gynecology and Obstetrics, 2017, 295 : 519 - 526
  • [30] Four-dimensional hysterosalpingo-contrast sonography with auxiliary hydrogen peroxide examination for the diagnosis of fallopian tube patency following interventional treatment of ovarian ectopic cysts
    Kong, Dejiao
    Dong, Xiaoqiu
    Wang, Zihan
    Zhang, Liwei
    Shao, Xiaohui
    Qi, Yunfeng
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2017, 295 (02) : 519 - 526