Clinical value of four-dimensional hysterosalpingo-contrast sonography assisted by intrauterine pressure measurement for tubal patency evaluation

被引:0
|
作者
Lin, Chunhong [1 ]
Chen, Jianyong [2 ]
Li, Xianguo [3 ]
Wang, Linlin [1 ]
Yan, Fengqin [1 ]
Chang, Ye [4 ]
Yang, Xueniu [5 ,6 ]
机构
[1] Hengshui Peoples Hosp, Dept Ultrasound 3, Hengshui, Hebei, Peoples R China
[2] Hubei Coll Chinese Med, Dept Med Med, Jingzhou, Hubei, Peoples R China
[3] Fifth Peoples Hosp Hengshui, Med Dept, Hengshui, Hebei, Peoples R China
[4] Hengshui Peoples Hosp, Dept Ultrasound 1, Hengshui, Hebei, Peoples R China
[5] Chongqing Populat & Family Planning Sci & Technol, NHC Key Lab Birth Defects & Reprod Hlth, Chongqing, Peoples R China
[6] Chongqing Populat & Family Planning Sci & Technol, Chongqing Key Lab Birth Defects & Reprod Hlth, NHC Key Lab Birth Defects & Reprod Hlth, Chongqing, Peoples R China
来源
INVESTIGACION CLINICA | 2023年 / 64卷 / 03期
关键词
tubal patency; 4D hysterosalpingo-contrast sonography; intrauterine pressure;
D O I
10.54817/IC.v64n3a5
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
We aimed to explore the clinical value of four-dimensional hys-terosalpingo-contrast sonography (4D-HyCoSy) assisted by intrauterine pres-sure measurement for evaluating tubal patency. One hundred and thirty-two patients diagnosed with tubal factor infertility from February 2018 to February 2021 were selected as subjects. With hysterosalpingography diagnosis results as the gold standard, 4D-HyCoSy was conducted for all patients, and the status of the fallopian tubes was classified into patency, occlusion, and partial occlusion. Based on the function of fallopian tubes, 4D-HyCoSy diagnosis results revealed that fallopian tubes showed bilateral patency, incomplete patency (including bilateral partial occlusion, unilateral patency, and unilateral partial occlusion, unilateral patency and unilateral occlusion), unilateral partial occlusion and unilateral occlusion, and bilateral occlusion. The cutoff value of peak intra-uterine pressure was determined using the receiver operating characteristic curve (ROC), specificity, and the area under the ROC curve (AUC) between 4D-HyCoSy alone and 4D-HyCoSy assisted by intrauterine pressure measure-ments. There were significant differences in the peak intrauterine pressure among patients with bilateral patency, incomplete patency, unilateral partial occlusion, and unilateral and bilateral occlusions (p<0.05). The corresponding cutoff values of peak intrauterine pressure were 24.42, 36.34, and 47.68 kPa; AUC values were 0.812, 0.836, and 0.827, respectively. The FSM model showed that the AUC of 4D-HyCoSy alone, assisted by peak intrauterine pressure was 0.85, with a higher sensitivity (88.13%) than that of 4D-HyCoSy (p<0.05). 4D-HyCoSy, assisted by intrauterine pressure measurement, has an excellent value for evaluating tubal patency.
引用
收藏
页码:317 / 328
页数:12
相关论文
共 50 条
  • [1] Evaluation of Tubal Patency with Transvaginal Three-dimensional Hysterosalpingo-contrast Sonography
    Qi Cheng
    Sha-sha Wang
    Xian-sheng Zhu
    Fan Li
    ChineseMedicalSciencesJournal, 2015, 30 (02) : 70 - 75
  • [2] Evaluation of tubal patency based on peak injection pressure in four-dimensional hysterosalpingo-contrast sonography among infertile females: a preliminary study
    Wang, Ling
    Chen, Xin
    He, Min
    Hu, Sha
    Ren, Quanlin
    Qi, Xiaoying
    Tan, Yifei
    Luo, Hong
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (05) : 3461 - 3472
  • [3] Value of three-dimensional hysterosalpingo-contrast sonography with SonoVue in the assessment of tubal patency
    Zhou, L.
    Zhang, X.
    Chen, X.
    Liao, L.
    Pan, R.
    Zhou, N.
    Di, N.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2012, 40 (01) : 93 - 98
  • [4] Hysterosalpingo-Contrast Sonography With Four-Dimensional Technique for Screening Fallopian Tubal Patency: Let's Make an Exploration
    Chen, Fenhong
    Quan, Juan
    Huang, Pintong
    You, Xiangdong
    JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2017, 24 (03) : 407 - 414
  • [5] Assessment of tubal patency by hysterosalpingo-contrast sonography in cow
    Itoh, K.
    Endo, N.
    Kataoka, S. I.
    Tanaka, T.
    JOURNAL OF ANIMAL SCIENCE, 2016, 94 : 56 - 57
  • [6] Hysterosalpingo-contrast sonography (HyCoSy) for determining tubal patency
    Degenhardt, F
    Jibril, S
    Eisenhauer, B
    CLINICAL RADIOLOGY, 1996, 51 : 15 - 18
  • [7] Hysterosalpingo-contrast sonography (HyCoSy) for determining tubal patency
    Degenhardt, F
    CLINICAL RADIOLOGY, 1996, 51 (12) : 893 - 893
  • [8] Diagnostic value of transvaginal four-dimensional hysterosalpingo-contrast sonography combined with recanalization in patients with tubal infertility
    Gao, Y. B.
    Yan, J. H.
    Yang, Y. D.
    Sun, J.
    Dong, J. Y.
    Cui, G. H.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2019, 22 (01) : 46 - 50
  • [9] Hysterosalpingo-contrast sonography versus radiographic hysterosalpingography in the evaluation of tubal patency
    Hamed, Hossam O.
    Shahin, Ahmed Y.
    Elsamman, Aly M.
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2009, 105 (03) : 215 - 217
  • [10] Confirmation of tubal patency in hysterosalpingo-contrast sonography by transvaginal hydrolaparoscopy
    Ahinko-Hakamaa, Katja Maarit
    Huhtala, Heini
    Tinkanen, Helena
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2009, 88 (03) : 286 - 290