Robotic-Assisted Total Knee Arthroplasty Has Similar Rates of Prosthetic Noise Generation as Conventional Total Knee Arthroplasty

被引:1
|
作者
Cozzarelli, Nicholas F. [1 ,2 ]
Khan, Irfan A. [1 ]
Imam, Nareena [1 ]
Klein, Gregg R. [1 ]
Levine, Harlan [1 ]
Seidenstein, Ari [1 ]
Zaid, Musa B. [1 ]
Lonner, Jess H. [1 ]
机构
[1] Rothman Orthopaed Inst, Div Adult Reconstruct, Philadelphia, PA USA
[2] Rothman Orthopaed Inst, 125 S 9th St,Ste 1000, Philadelphia, PA 19107 USA
来源
ARTHROPLASTY TODAY | 2023年 / 23卷
关键词
Total knee arthroplasty; TKA; Robotic assisted; Noise generation; Satisfaction; YOUNG-PATIENTS;
D O I
10.1016/j.artd.2023.101216
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Noise has been reported to occur with relatively high frequency after conventional total knee arthroplasty (C-TKA), and this may impact the incidence of patient satisfaction and function. The purpose of this study was to compare the rate of patient-reported prosthetic noise generation after robotically-assisted TKA (RA-TKA) and C-TKA.Methods: A retrospective study was conducted of unilateral primary RA-TKAs and C-TKAs performed between 2018 and 2021. Patients completed a survey consisting of 4 Likert scale questions related to prosthetic noise generation and Knee Injury and Osteoarthritis Score Joint Replacement and Forgotten Joint Score were assessed prospectively preoperatively and at a minimum of 1-year of clinical follow-up. Statistical analysis was done utilizing T-tests and chi-square tests, with statistical significance defined as a P-value < .05.Results: One hundred sixty-two RA-TKAs and 320 C-TKAs with similar baseline characteristics and functions were included. There were no significant differences in hearing or feeling grinding, popping, clicking, or clunking (40.7% vs 38.1%; P = .647) between groups. Most RA-TKAs and C-TKAs were not dissatisfied regarding noise generation (70.4% vs 73.1%; P = .596). In both cohorts, patients who reported noise generation had lower average Forgotten Joint Scores (45.5 vs 66.1; P < .001) and lower postoperative Knee Injury and Osteoarthritis Score Joint Replacement scores (72.0 vs 81.4; P < .001) than those who did not experience noise generation.Conclusions: While RA-TKA may facilitate soft tissue balancing, there were no differences in prosthetic noise generation between RA-TKA and C-TKA. However, those who experience implant-generated noise have lower functional outcome scores.(c) 2023 The Authors. Published by Elsevier Inc. on behalf of The American Association of Hip and Knee Surgeons. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/ licenses/by-nc-nd/4.0/).
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Robotic-assisted total knee arthroplasty is comparable to conventional total knee arthroplasty: a meta-analysis and systematic review
    James Randolph Onggo
    Jason Derry Onggo
    Richard De Steiger
    Raphael Hau
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 1533 - 1549
  • [2] Robotic-assisted total knee arthroplasty is comparable to conventional total knee arthroplasty: a meta-analysis and systematic review
    Onggo, James Randolph
    Onggo, Jason Derry
    De Steiger, Richard
    Hau, Raphael
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (10) : 1533 - 1549
  • [3] Conversion of Patellofemoral Arthroplasty to Robotic-Assisted Total Knee Arthroplasty
    Lachance, Andrew D.
    Steika, Roman
    Lutton, Jeffrey
    Austin, David
    ARTHROPLASTY TODAY, 2023, 23
  • [4] Outcomes following robotic assisted total knee arthroplasty compared to conventional total knee arthroplasty
    Aggarwal, Vikram A.
    Sun, Joshua
    Sambandam, Senthil N.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (05) : 2223 - 2227
  • [5] Robotic-assisted total knee arthroplasty demonstrates decreased postoperative pain and opioid usage compared to conventional total knee arthroplasty
    Bhimani, S. J.
    Bhimani, R.
    Smith, A.
    Eccles, C.
    Smith, L.
    Malkani, A.
    BONE & JOINT OPEN, 2020, 1 (02): : 8 - 12
  • [6] Robotic-Assisted Total Knee Arthroplasty in Obese Patients
    Richardson, Mary K.
    Digiovanni, Ryan M.
    McCrae, Brian K.
    Cooperman, Wesley S.
    Ludington, John
    Heckmann, Nathanael D.
    Oakes, Daniel A.
    ARTHROPLASTY TODAY, 2024, 26
  • [7] Not All Robotic-assisted Total Knee Arthroplasty Are the Same
    Siddiqi, Ahmed
    Mont, Michael A.
    Krebs, Viktor E.
    Piuzzi, Nicolas S.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2021, 29 (02) : 45 - 59
  • [8] The Current Role of Robotic-assisted Total Knee Arthroplasty
    Rodriguez-Merchan, E. Carlos
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2022, 10 (12): : 989 - 991
  • [9] What are the benefits of robotic-assisted total knee arthroplasty over conventional manual total knee arthroplasty? A systematic review of comparative studies
    Mancino, Fabio
    Cacciola, Giorgio
    Malahias, Michael-Alexander
    De Filippis, Roberto
    De Marco, Davide
    Di Matteo, Vincenzo
    Gu, A.
    Sculco, Peter K.
    Maccauro, Giulio
    De Martino, Ivan
    ORTHOPEDIC REVIEWS, 2020, 12 : 15 - 22
  • [10] Comparison of robotic-assisted and conventional manual implantation of a primary total knee arthroplasty
    Park, Sang Eun
    Lee, Chun Taek
    JOURNAL OF ARTHROPLASTY, 2007, 22 (07): : 1054 - 1059