The validity of using bare graphite electrode for the voltammetric determination of paracetamol and caffeine

被引:4
|
作者
Stoytcheva, Margarita [1 ]
Zlatev, Roumen [1 ]
Velkova, Zdravka [2 ]
Gochev, Velizar [3 ]
Meza, Claudia [1 ]
Valdez, Benjamin [1 ]
Kirova, Gergana [2 ]
Hristova, Yana [3 ]
Toscano-Palomar, Lydia [4 ]
机构
[1] Univ Autonoma Baja Calif, Inst Ingn, Mexicali, Mexico
[2] Med Univ Plovdiv, Fac Pharm, Dep Chem Sci, Plovdiv, Bulgaria
[3] Plovdiv Univ P Hilendarski, Fac Biol, Dep Biochem & Microbiol, Plovdiv, Bulgaria
[4] Tecnol Nacl Mexico, Inst Tecnol Mexicali, Mexicali, Mexico
来源
关键词
Paracetamol; Caffeine; Graphite electrode; Adsorptive stripping voltammetry; ELECTROCHEMICAL DETERMINATION; CARBON; PHARMACEUTICALS; ACETAMINOPHEN;
D O I
10.1016/j.ijoes.2023.100120
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The validity of applying the readily available bare spectroscopic graphite electrode in the pharmaceutical analysis as a cost-effective, simple, and efficient alternative to the modified carbon-based electrodes was eval-uated in this work using paracetamol and caffeine as test analytes. The cyclic voltammetry study on their electrochemical behavior revealed that paracetamol and caffeine display well-expressed oxidation peaks at potentials of typically 0.51 V and 1.36 V vs. Ag, AgCl/KClsat, correspondingly and that their oxidation is an adsorption-controlled process. Then the bare spectroscopic graphite electrode was applied for the separate and individual determination of the test analytes by differential pulse adsorptive stripping voltammetry. Under optimized experimental conditions (3 min accumulation time, pH 5.0) the electrode exhibited a linear response to paracetamol in the range from 5 mu mol L-1 to 150 mu mol L-1 and to caffeine in the range from 5 mu mol L-1 to 60 mu mol L-1. The detection limit achieved (0.2 mu mol L-1 for each of the analytes) was found to be sufficient to carry out paracetamol and/or caffeine analysis in drugs. The results were validated by separate and individual paracetamol and caffeine determinations in commercial tablets with satisfactory recovery values (98.90-101.85 %). The presence of common pharmaceutical excipients did not affect the paracetamol and/or caffeine voltammetric response.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] VOLTAMMETRIC DETERMINATION OF 1,3-DIOXOLANE HYDROPEROXIDES USING A GRAPHITE ELECTRODE
    KURAMSHIN, EM
    YUFEREVA, LA
    MAISTRENKO, VN
    ZLOTSKII, SS
    RAKHMANKULOV, DL
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1984, 39 (02): : 283 - 285
  • [32] Rapid Voltammetric Screening Method for the Assessment of Bioflavonoid Content Using the Disposable Bare Pencil Graphite Electrode
    David, Iulia Gabriela
    Numan, Nimet
    Buleandra, Mihaela
    Popa, Dana-Elena
    Litescu, Simona Carmen
    Riga, Sorin
    Ciobanu, Adela Magdalena
    CHEMOSENSORS, 2021, 9 (11)
  • [33] A disposable voltammetric sensor for the determination of diphenylamine using modified pencil graphite electrode
    Santhy Antherjanam
    Beena Saraswathyamma
    Analytical Sciences, 2024, 40 : 163 - 174
  • [34] VOLTAMMETRIC DETERMINATION OF SOME DRUGS USING SILICONE RUBBER BASED GRAPHITE ELECTRODE
    PUNGOR, E
    FEHER, Z
    NAGY, G
    ACTA CHIMICA ACADEMIAE SCIENTARIUM HUNGARICAE, 1971, 70 (03): : 207 - &
  • [35] A disposable voltammetric sensor for the determination of diphenylamine using modified pencil graphite electrode
    Antherjanam, Santhy
    Saraswathyamma, Beena
    ANALYTICAL SCIENCES, 2024, 40 (01) : 163 - 174
  • [36] A voltammetric method for rapid determination of palladium in a phosphate electrolyte using a graphite electrode
    Kiryushov, VN
    Kletenik, YB
    INDUSTRIAL LABORATORY, 1997, 63 (02): : 63 - 65
  • [37] Sensitive adsorptive stripping voltammetric determination of paracetamol at multiwalled carbon nanotube modified basal plane pyrolytic graphite electrode
    Kachoosangi, Roohollah Torabi
    Wildgoose, Gregory G.
    Compton, Richard G.
    ANALYTICA CHIMICA ACTA, 2008, 618 (01) : 54 - 60
  • [38] Voltammetric determination of paracetamol in pharmaceutical tablet samples using anthraquinone modified carbon paste electrode
    Amare, Meareg
    Teklay, Welday
    COGENT CHEMISTRY, 2019, 5 (01):
  • [39] Novel cork-graphite electrochemical sensor for voltammetric determination of caffeine
    Monteiro, Mayra K. S.
    Paiva, Suelya S. M.
    da Silva, Djalma R.
    Vilar, Vitor J. P.
    Martinez-Huitle, Carlos A.
    dos Santos, Elisama V.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 839 : 283 - 289
  • [40] Simultaneous Square-Wave Voltammetric Determination of Paracetamol, Caffeine and Orphenadrine in Pharmaceutical Formulations Using a Cathodically Pretreated Boron-Doped Diamond Electrode
    Pires Eisele, Ana Paula
    Clausen, Debora Nobile
    Teixeira Tarley, Cesar Ricardo
    Dall'Antonia, Luiz Henrique
    Sartori, Elen Romao
    ELECTROANALYSIS, 2013, 25 (07) : 1734 - 1741