Accelerated Damage in Metallized Film Capacitors Under Pulse Surge Combined With Rated DC Voltage

被引:1
|
作者
Zhang, Chuansheng [1 ,2 ]
Feng, Yu [1 ]
Kong, Fei [1 ]
Xing, Zhaoliang [3 ]
Zhang, Cheng [1 ,2 ]
Shao, Tao [1 ,2 ]
机构
[1] Chinese Acad Sci, Inst Elect Engn, Beijing Int S&T Cooperat Base Plasma Science&Energ, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Sch Elect Elect & Commun Engn, Beijing 100049, Peoples R China
[3] State Grid Smart Grid Res Inst Co Ltd, State Key Lab Adv Power Transmiss Technol, Beijing 102209, Peoples R China
基金
中国国家自然科学基金;
关键词
Capacitors; Capacitance; Electrodes; Resistance; Dielectrics; Plasma temperature; Electric breakdown; Capacitance loss; equivalent series resistance (ESR); metallized film capacitors (MFCs); repetitive pulses; self-healing; TEMPERATURE RISE; RELIABILITY;
D O I
10.1109/TPS.2023.3272695
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
Metallized film capacitors (MFCs) have good self-healing performance and are widely used in pulsed power supplies, power systems, and aerospace equipment. The self-healing time of MFCs is often in the order of microseconds. When the pulsewidth of overvoltage is close to the self-healing time, MFCs are at risk of insulation failure. In this article, self-healing energy and time under pulse surge combined with rated dc voltage are investigated by analyzing the effect of the number of applied pulses on the capacitance loss, dielectric loss, and equivalent series resistance (ESR) of MFC. The correlation between the number of applied pulses and the capacitance loss of MFC at different repetition frequencies, pulse components, and temperatures is studied, fitting the 5% turning points of capacitance loss. The experimental results show that the multiple types of self-healing occur in an active period of one pulse under microsecond overvoltage. According to the level of injection energy and several typical waveforms from voltage and current, the self-healing process of MFC can be classified into effective self-healing, disruptive self-healing, and fatal self-healing. When effective self-healing occurs in the MFC, the performances remain stable for a certain time. As the number of tolerated pulses increases, disruptive self-healing and fatal self-healing significantly decrease capacitance value but increase dielectric loss and ESR.
引用
收藏
页码:1494 / 1501
页数:8
相关论文
共 50 条
  • [21] Metallized Film Capacitors Degradation under High Electrodynamic Load
    Belko, Victor O.
    Emelyanov, Oleg A.
    Ivanov, Ivan O.
    Glivenko, Dmitry Y.
    PROCEEDINGS OF THE 2017 IEEE RUSSIA SECTION YOUNG RESEARCHERS IN ELECTRICAL AND ELECTRONIC ENGINEERING CONFERENCE (2017 ELCONRUS), 2017, : 1120 - 1122
  • [22] The Diagnostics of Metallized Film Capacitors under Soft Training Test
    Belko, Victor
    Emelyanov, Oleg
    Ivanov, Ivan
    Starovoytenkov, Victor
    2020 INTERNATIONAL CONFERENCE ON DIAGNOSTICS IN ELECTRICAL ENGINEERING, DIAGNOSTIKA, 2020, : 150 - 153
  • [23] Self-healing Characteristics and Life Prediction of Metallized Film Capacitor Under DC Voltage
    Li Z.
    Wang J.
    Xu Z.
    Wang X.
    Cheng L.
    Liu W.
    Gaodianya Jishu/High Voltage Engineering, 2023, 49 (07): : 2929 - 2937
  • [24] Failure mechanism of metallized film capacitors under DC field superimposed AC harmonic: From equipment to material
    Li, Zhiyuan
    Zhou, Yihan
    Wang, Xuguang
    Liu, Hongbo
    Cheng, Lu
    Liu, Wenfeng
    Li, Shengtao
    Guo, Jiang
    Xu, Yang
    HIGH VOLTAGE, 2024,
  • [25] Modeling of ESR in metallized film capacitors and its implication on pulse handling capability
    Li, Hua
    Huang, Xiang
    Li, Zhiwei
    Li, Haoyuan
    Wang, Wenjuan
    Wang, Bowen
    Zhang, Qin
    Lin, Fuchang
    MICROELECTRONICS RELIABILITY, 2015, 55 (07) : 1046 - 1053
  • [26] Electrical Tree in Silicone Rubber under Voltage Combined of DC and Pulse
    Wang, Fuyu
    Han, Tao
    Su, Jingang
    Guo, Yaguang
    2018 IEEE 2ND INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD), 2018,
  • [27] Accelerated Degradation Testing and Failure Mechanism Analysis of Metallized Film Capacitors for AC Filtering
    Yao, Bo
    Wei, Xing
    Zhang, Yichi
    Correia, Pedro
    Wu, Rui
    Song, Sungyoung
    Trintis, Ionut
    Wang, Haoran
    Wang, Huai
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2024, 39 (05) : 6256 - 6270
  • [28] Capacitance Loss Analysis of Metallized Film Capacitors under AC Condition
    Li, Zheng
    Li, Hua
    Lin, Fuchang
    Wang, Zhehao
    Zhang, Guohao
    Qi, Liang
    PROCEEDINGS OF THE 2020 3RD IEEE INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD 2020), 2020, : 173 - 176
  • [29] Self-healing Characteristics of Metallized Film Capacitor under DC and AC Superimposed Voltage with Harmonics
    Zheng, Linzi
    Zhu, Lingyu
    Liu, Junjie
    Di, Zhenguo
    Ji, Shengchang
    2022 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (IEEE CEIDP 2022), 2022, : 175 - 178
  • [30] Manufacturing technology effect on current pulse handling performance of metallized polypropylene film capacitors
    El-Husseini, MH
    Venet, P
    Al-Majid, A
    Fathallah, M
    Rojat, G
    Ferreira, JA
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2003, 36 (18) : 2295 - 2303