The longitudinal energy spread of ion beams extracted from an electron cyclotron resonance ion source

被引:1
|
作者
Angot, J. [1 ]
Tarvainen, O. [2 ]
Chauveau, P. [3 ]
Kosonen, S. T. [4 ]
Kalvas, T. [4 ]
Thuillier, T. [1 ]
Migliore, M. [1 ]
Maunoury, L. [3 ]
机构
[1] Univ Grenoble Alpes, CNRS, Grenoble INP, LPSC IN2P3, F-38000 Grenoble, France
[2] Rutherford Appleton Lab, STFC ISIS Pulsed Spallat Neutron & Muon Facil, Harwell OX11 0QX, England
[3] Grand Accelerateur Natl Ions Lourds GANIL, F-14076 Caen 5, France
[4] Univ Jyvdskyld, Accelerator Lab, Dept Phys, Survontie 9, FIZ-40500 Jyvdskyld, Finland
关键词
Ion sources (positive ions; negative ions; electron cyclotron resonance (ECR); electron beam (EBIS)); Instrumentation for particle accelerators and storage rings-low energy (linear accelerators; cyclotrons; electrostatic accelerators);
D O I
10.1088/1748-0221/18/04/P04018
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present a study of factors affecting the energy spread of ion beams extracted from a Charge Breeder Electron Cyclotron Resonance Ion Source (CB-ECRIS). The comprehensive simulations, supported by experiments with a Retarding Field Analyser (RFA), reveal that the longitudinal and transverse energy spread of the extracted beams are strongly affected by the electrostatic focusing effects, namely the extraction geometry and plasma beam boundary, to the extent that the electrostatic effects dominate over the magnetic field induced rotation of the beam or the effect of plasma potential and ion temperature. The dominance of the electrostatic focusing effect over the magnetic field induced rotation complicates parametric studies of the transverse emittance as a function of the magnetic field strength, and comparison of emittance values obtained with different ion sources having different extraction designs. Our results demonstrate that the full ion beam energy spread, relevant for the downstream accelerator, can be measured with the RFA only when all ions are collected. On the contrary, studying the effect of plasma properties (plasma potential and ion temperature) on the longitudinal energy spread requires heavy collimation of the beam accepting only ions near the symmetry axis of the beam for which the electrostatic and magnetic effects are suppressed. As the extraction system of the CB-ECRIS is similar to a conventional ECRIS, the conclusions of the study can be generalised to apply for all high charge state ECR ion sources. Finally, we present the results of systematic plasma potential measurements of the Phoenix-type CB-ECRIS at LPSC, varying the source potential, the microwave power and the axial magnetic field srength. It was observed that the plasma potential increases with the extraction magnetic field and the microwave power.
引用
收藏
页数:42
相关论文
共 50 条
  • [31] Production of highly charged ion beams from electron cyclotron resonance ion sources (invited)
    Xie, ZQ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02): : 625 - 630
  • [32] Production of beams from solid materials at Center for Nuclear Study electron cyclotron resonance ion source
    Ohshiro, Y.
    Yamaka, S.
    Watanabe, S.
    Kobayashi, K.
    Kotaka, Y.
    Nishimura, M.
    Kase, M.
    Muto, H.
    Yamaguchi, H.
    Shimoura, S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (02):
  • [33] Metallic ion production with electron cyclotron resonance ion source Caprice
    Barue, C
    Bossler, J
    Schennach, S
    Schulte, H
    Wolf, BH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (03): : 1368 - 1370
  • [34] Analysis and recombination of multiple-charge-state beams from an electron cyclotron resonance ion source
    Ostroumov, P. N.
    Kondrashev, S. A.
    Mustapha, B.
    Scott, R.
    Vinogradov, N. E.
    PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2009, 12 (01):
  • [36] A new 18 GHz room temperature electron cyclotron resonance ion source for highly charged ion beams
    Koivisto, H.
    Ikonen, A.
    Kalvas, T.
    Kosonen, S.
    Kronholm, R.
    Marttinen, M.
    Tarvainen, O.
    Toivanen, V.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (02):
  • [37] Effect of Mid-Electrode Potential on Multi-Charged Ion Beam Extracted from Electron Cyclotron Resonance Ion Source
    Imai, Y.
    Kimura, D.
    Yano, K.
    Kumakura, S.
    Nishiokada, T.
    Sato, F.
    Kato, Y.
    Iida, T.
    Muramatsu, M.
    Kitagawa, A.
    2014 20TH INTERNATIONAL CONFERENCE ON ION IMPLANTATION TECHNOLOGY (IIT 2014), 2014,
  • [39] Production of intense highly charged ion beams by IMP 14.5 GHz electron cyclotron resonance ion source
    Zhao, Hongwei
    Zhang, Zimin
    Zhang, Xuezhen
    Zhao, Yubin
    Guo, Xiaohong
    Liu, Zhanwen
    Li, Xixia
    Wang, Yifang
    Wei, Baowen
    Nuclear Science and Techniques/Hewuli, 2000, 11 (03): : 145 - 149
  • [40] Study of slowing down and thermalization of externally injected ion beams in electron cyclotron resonance ion source plasmas
    Babu, Paritosh Sing
    Naik, Vaishali
    PHYSICS OF PLASMAS, 2019, 26 (03)