Slice-specific tracking for free-breathing diffusion tensor cardiac MRI

被引:0
|
作者
Xu, Xi [1 ,2 ]
Hu, Junpu [3 ]
Zheng, Yijia [1 ]
Liu, Yuanyuan [1 ]
Cui, Zhuoxu [1 ]
Liang, Dong [2 ,4 ]
Zhu, Yanjie [1 ,5 ]
机构
[1] Chinese Acad Sci, Shenzhen Inst Adv Technol, Paul C Lauterbur Res Ctr Biomed Imaging, Shenzhen, Peoples R China
[2] Univ Chinese Acad Sci, Shenzhen Coll Adv Technol, Shenzhen, Peoples R China
[3] United Imaging Healthcare, Shanghai, Peoples R China
[4] Chinese Acad Sci, Shenzhen Inst Adv Technol, Res Ctr Med AI, Shenzhen, Peoples R China
[5] Chinese Acad Sci, Shenzhen Inst Adv Technol, Paul C Lauterbur Res Ctr Biomed Imaging, Shenzhen 518055, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
cardiac magnetic resonance; diffusion tensor imaging; free breathing; motion correction; navigator; slice tracking; HUMAN HEART; RESPIRATORY MOTION; SPIN-ECHO; REPRODUCIBILITY; HOLD;
D O I
10.1002/nbm.4922
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
BackgroundDiffusion tensor cardiac magnetic resonance (DT-CMR) imaging has great potential to characterize myocardial microarchitecture. However, its accuracy is limited by respiratory and cardiac motion and long scan times. Here, we develop and evaluate a slice-specific tracking method to improve the efficiency and accuracy of DT-CMR acquisition during free breathing. MethodsCoronal images were obtained along with signals from a diaphragmatic navigator. Respiratory and slice displacements were obtained from the navigator signals and coronal images, respectively, and these displacements were fitted with a linear model to obtain the slice-specific tracking factors. This method was evaluated in DT-CMR examinations of 17 healthy subjects, and the results were compared with those obtained using a fixed tracking factor of 0.6. DT-CMR with breath-holding was used for reference. Quantitative and qualitative evaluation methods were used to analyze the performance of the slice-specific tracking method and the consistency between the obtained diffusion parameters. ResultsIn the study, the slice-specific tracking factors showed an upward trend from the basal to the apical slice. Residual in-plane movements were lower in slice-specific tracking than in fixed-factor tracking (RMSE: 2.748 +/- 1.171 versus 5.983 +/- 2.623, P < 0.001). The diffusion parameters obtained using slice-specific tracking were not significantly different from those obtained from breath-holding acquisition (P > 0.05). ConclusionIn free-breathing DT-CMR imaging, the slice-specific tracking method reduced misalignment of the acquired slices. The diffusion parameters obtained using this approach were consistent with those obtained with the breath-holding technique.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Free-breathing pediatric MRI with nonrigid motion correction and acceleration
    Cheng, Joseph Y.
    Zhang, Tao
    Ruangwattanapaisarn, Nichanan
    Alley, Marcus T.
    Uecker, Martin
    Pauly, John M.
    Lustig, Michael
    Vasanawala, Shreyas S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (02) : 407 - 420
  • [42] Graph-based retrospective 4D Image construction from free-breathing MRI slice acquisitions
    Tong, Yubing
    Udupa, Jayaram K.
    Ciesielski, Krzysztof C.
    McDonough, Joseph M.
    Mong, Andrew
    Campbell, Robert M.
    MEDICAL IMAGING 2014: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2014, 9038
  • [43] Diffusion tensor MRI of the human heart In Vivo with a navigator based free breathing approach
    Sonia Nielles-Vallespin
    Choukri Mekkaoui
    Peter D Gatehouse
    Timothy G Reese
    Jennifer Keegan
    Steven Collins
    Peter Speier
    Thorsten Feiweier
    Marcel P Jackowski
    David E Sosnovik
    David N Firmin
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [44] 4D image construction from free-breathing MRI slice acquisitions of the thorax based on a concept of flux
    Hao, You
    Udup, Jayaram K.
    Tong, Yubing
    Wu, Caiyun
    Li, Hua
    McDonough, Joseph M.
    Torigian, Drew A.
    Cahill, Patrick J.
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [45] Real-Time Prediction in Free-Breathing Perfusion MRI
    Song, H.
    Liu, W.
    Ruan, D.
    Jung, S.
    Gach, M.
    MEDICAL PHYSICS, 2014, 41 (06) : 440 - +
  • [46] Relevance of lesion size in navigator-triggered and free-breathing diffusion-weighted liver MRI
    Reithmeier, Bianca
    Laun, Frederik B.
    Fuehres, Tobit
    Uder, Michael
    Bickelhaupt, Sebastian
    Saake, Marc
    EUROPEAN RADIOLOGY, 2025, 35 (04) : 2106 - 2115
  • [47] A new strategy for respiration compensation, applied toward 3D free-breathing cardiac MRI
    Madore, Bruno
    Farnebaeck, Gunnar
    Westin, Carl-Fredrik
    Duran-Mendicuti, Alejandra
    MAGNETIC RESONANCE IMAGING, 2006, 24 (06) : 727 - 737
  • [48] 3-D cardiac MRI in free-breathing newborns and infants: when is respiratory gating necessary?
    Achim Seeger
    Patrick Krumm
    Andreas Hornung
    Jürgen F. Schäfer
    Ulrich Kramer
    Ludger Sieverding
    Pediatric Radiology, 2015, 45 : 1448 - 1454
  • [49] Joint Image Reconstruction and Motion Parameter Estimation for Free-Breathing Navigator-Gated Cardiac MRI
    Akcakaya, Mehmet
    Basha, Tamer A.
    Weingaertner, Sebastian
    Nezafat, Reza
    WAVELETS AND SPARSITY XV, 2013, 8858
  • [50] 3-D cardiac MRI in free-breathing newborns and infants: when is respiratory gating necessary?
    Seeger, Achim
    Krumm, Patrick
    Hornung, Andreas
    Schaefer, Juergen F.
    Kramer, Ulrich
    Sieverding, Ludger
    PEDIATRIC RADIOLOGY, 2015, 45 (10) : 1448 - 1454