共 50 条
Slice-specific tracking for free-breathing diffusion tensor cardiac MRI
被引:0
|作者:
Xu, Xi
[1
,2
]
Hu, Junpu
[3
]
Zheng, Yijia
[1
]
Liu, Yuanyuan
[1
]
Cui, Zhuoxu
[1
]
Liang, Dong
[2
,4
]
Zhu, Yanjie
[1
,5
]
机构:
[1] Chinese Acad Sci, Shenzhen Inst Adv Technol, Paul C Lauterbur Res Ctr Biomed Imaging, Shenzhen, Peoples R China
[2] Univ Chinese Acad Sci, Shenzhen Coll Adv Technol, Shenzhen, Peoples R China
[3] United Imaging Healthcare, Shanghai, Peoples R China
[4] Chinese Acad Sci, Shenzhen Inst Adv Technol, Res Ctr Med AI, Shenzhen, Peoples R China
[5] Chinese Acad Sci, Shenzhen Inst Adv Technol, Paul C Lauterbur Res Ctr Biomed Imaging, Shenzhen 518055, Guangdong, Peoples R China
基金:
中国国家自然科学基金;
关键词:
cardiac magnetic resonance;
diffusion tensor imaging;
free breathing;
motion correction;
navigator;
slice tracking;
HUMAN HEART;
RESPIRATORY MOTION;
SPIN-ECHO;
REPRODUCIBILITY;
HOLD;
D O I:
10.1002/nbm.4922
中图分类号:
Q6 [生物物理学];
学科分类号:
071011 ;
摘要:
BackgroundDiffusion tensor cardiac magnetic resonance (DT-CMR) imaging has great potential to characterize myocardial microarchitecture. However, its accuracy is limited by respiratory and cardiac motion and long scan times. Here, we develop and evaluate a slice-specific tracking method to improve the efficiency and accuracy of DT-CMR acquisition during free breathing. MethodsCoronal images were obtained along with signals from a diaphragmatic navigator. Respiratory and slice displacements were obtained from the navigator signals and coronal images, respectively, and these displacements were fitted with a linear model to obtain the slice-specific tracking factors. This method was evaluated in DT-CMR examinations of 17 healthy subjects, and the results were compared with those obtained using a fixed tracking factor of 0.6. DT-CMR with breath-holding was used for reference. Quantitative and qualitative evaluation methods were used to analyze the performance of the slice-specific tracking method and the consistency between the obtained diffusion parameters. ResultsIn the study, the slice-specific tracking factors showed an upward trend from the basal to the apical slice. Residual in-plane movements were lower in slice-specific tracking than in fixed-factor tracking (RMSE: 2.748 +/- 1.171 versus 5.983 +/- 2.623, P < 0.001). The diffusion parameters obtained using slice-specific tracking were not significantly different from those obtained from breath-holding acquisition (P > 0.05). ConclusionIn free-breathing DT-CMR imaging, the slice-specific tracking method reduced misalignment of the acquired slices. The diffusion parameters obtained using this approach were consistent with those obtained with the breath-holding technique.