Clinical accuracy of partially guided implant placement in edentulous patients: A computed tomography-based retrospective study

被引:0
|
作者
Wang, Baixiang [1 ]
Yang, Jiakang [1 ]
Siow, Lixuen [1 ]
Wang, Yu [1 ]
Zhang, Xinyue [1 ]
Zhou, Yiqun [1 ]
Yu, Mengfei [1 ]
Wang, Huiming [1 ]
机构
[1] Zhejiang Univ, Canc Ctr Zhejiang Univ, Stomatol Hosp, Zhejiang Prov Clin Res Ctr Oral Dis,Sch Stomatol,K, Hangzhou, Peoples R China
关键词
CBCT; dental implants; deviation; template-guided surgery; whole-arch restoration; SURGERY; NAVIGATION; POSITIONS; SUPPORT; MAXILLA;
D O I
10.1111/clr.14191
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives:<bold> </bold>This retrospective study was intended to evaluate the clinical accuracy of partially guided template in guiding implant placement in edentulous patients. Methods:<bold> </bold>A total of 120 implants were placed in 24 patients with at least one completely edentulous arch with a partially guided system. Based on CBCT data, a repeatable method was used to measure linear and angular deviations of implants at 3D level in Mimics medical software. The influence of supporting tissue and implant region on the accuracy was assessed, followed by the evaluation of direction of linear deviations in biologically vital areas. Results: Linear deviations of all implants were 1.91 +/- 0.68 mm, 1.47 +/- 0.68 mm, and 1.02 +/- 0.69 mm at apical, apical lateral, and apical vertical levels. When at the cervical, cervical lateral, and cervical vertical levels, the linear deviations were 1.53 +/- 0.65 mm, 0.98 +/- 0.53 mm, and 1.01 +/- 0.69 mm, respectively. Angular deviation of all implants was 7.14 +/- 3.41 degrees. Implants guided by mucosa + tooth-supported templates showed higher linear deviations at apical vertical level (1.21 +/- 0.72 mm vs. 0.86 +/- 0.63 mm, p < .05) and cervical vertical level (1.18 +/- 0.72 mm vs. 0.87 +/- 0.63 mm, p < .05) than mucosa-supported templates, and implants in maxilla were found higher angular deviation than mandible (7.89 +/- 3.61 degrees vs. 6.29 +/- 2.97 degrees, p < .05). Conclusions:<bold> </bold>The partially guided template served as clinically viable surgical assistance in implant placement in edentulous patients. When using mucosa + tooth-supported template or placing implants in maxilla, more caution was required, especially in biologically vital areas.
引用
收藏
页码:31 / 39
页数:9
相关论文
共 50 条
  • [41] Accuracy of computer navigation in total knee arthroplasty: A prospective computed tomography-based study
    Hannan, Richard
    Free, Matthew
    Arora, Varun
    Harle, Robin
    Harvie, Paul
    [J]. MEDICAL ENGINEERING & PHYSICS, 2020, 79 : 52 - 59
  • [42] Computed tomography-based classification of axis vertebra: choice of screw placement
    Nupur Pruthi
    Rose Dawn
    Yogitha Ravindranath
    Tanmoy Kumar Maiti
    Roopa Ravindranath
    Mariamma Philip
    [J]. European Spine Journal, 2014, 23 : 1084 - 1091
  • [43] Computed tomography-based classification of axis vertebra: choice of screw placement
    Pruthi, Nupur
    Dawn, Rose
    Ravindranath, Yogitha
    Maiti, Tanmoy Kumar
    Ravindranath, Roopa
    Philip, Mariamma
    [J]. EUROPEAN SPINE JOURNAL, 2014, 23 (05) : 1084 - 1091
  • [44] Retropharyngeal lymphadenopathy in patients with nasopharyngeal carcinoma - A computed tomography-based study
    Chua, DTT
    Sham, JST
    Kwong, DLW
    Au, GKH
    Choy, DTK
    [J]. CANCER, 1997, 79 (05) : 869 - 877
  • [45] Accuracy of Image-Guided Pedicle Screw Placement Using Intraoperative Computed Tomography-Based Navigation With Automated Referencing, Part I: Cervicothoracic Spine
    Scheufler, Kai-Michael
    Franke, Joerg
    Eckardt, Anke
    Dohmen, Hildegard
    [J]. NEUROSURGERY, 2011, 69 (04) : 782 - 795
  • [46] Accuracy of Subaxial Cervical Pedicle Screw Placement Using Direct Visualization Versus Computed Tomography-Based Navigation
    Farber, S. Harrison
    Godzik, Jakub
    Hlubek, Randall J.
    Zhou, James J.
    Walker, Corey T.
    Kakarla, U. Kumar
    Uribe, Juan S.
    Turner, Jay D.
    [J]. CLINICAL SPINE SURGERY, 2022, 35 (01): : E104 - E110
  • [47] Assessment of thickness of roof of the glenoid fossa in dentate, edentulous, and partially edentulous subjects using cone beam computed tomography (CBCT)- a retrospective study
    Veettil, Aiswarya Chandran Kana
    Shantha, Abhinethra Mariyappa
    Ashwathappa, Deepak Timmasandra
    Choudary, Amirneni Sailaja
    Lingaiah, Upasana
    [J]. JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2022, 123 (05) : E279 - E284
  • [48] Trephination-based, guided surgical implant placement: A clinical study
    Suriyan, Nawakamon
    Sarinnaphakorn, Lertrit
    Deeb, George R.
    Bencharit, Sompop
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (03): : 411 - 416
  • [49] Anterior Transarticular Crossing Screw Placement for Atlantoaxial Instability in Children: Computed Tomography-Based Study
    Liu, Qi
    Lin, Junyu
    Yin, Yongjie
    Liu, Yapu
    Huang, Zucheng
    Liu, Junhao
    Li, Ruoyao
    Ji, Wei
    [J]. WORLD NEUROSURGERY, 2022, 161 : E192 - E198
  • [50] Implant Placement in Patients under Treatment with Rivaroxaban: A Retrospective Clinical Study
    Galletti, Guido
    Alfonsi, Fortunato
    Raffaele, Angelo
    Alberto Valente, Nicola
    Chatelain, Sibylle
    Kolerman, Roni
    Cinquini, Chiara
    Romeggio, Stefano
    Iezzi, Giovanna
    Barone, Antonio
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (12) : 1 - 13