Cancer cell detection by plasmonic dual V-shaped PCF biosensor

被引:2
|
作者
Abdelghaffar, M. [1 ,2 ,3 ]
Gamal, Yusuf [3 ,4 ]
El-Khoribi, Reda A. [1 ]
Soliman, Wafaa [2 ]
Badr, Y. [2 ]
Hameed, Mohamed Farhat O. [5 ,6 ]
Obayya, S. S. A. [3 ,7 ]
机构
[1] Cairo Univ, Fac Comp & Artificial Intelligence, Giza, Egypt
[2] Cairo Univ, Natl Inst Laser Enhanced Sci NILES, Laser Sci & Interact Dept, Giza, Egypt
[3] Ctr Photon & Smart Mat, Zewail City Sci Technol & Innovat, 6th Of October City 12578, Giza, Egypt
[4] Cairo Univ, Natl Inst Laser Enhanced Sci NILES, Engn Applicat Laser Dept, Giza, Egypt
[5] Zewail City Sci Technol & Innovat, Ctr Nanotechnol, 6th Of October City 12588, Giza, Egypt
[6] Univ Mansoura, Fac Engn, Dept Math & Engn Phys, Mansoura 35516, Egypt
[7] Univ Mansoura, Fac Engn, Dept Elect & Commun Engn, Mansoura 35516, Egypt
关键词
PHOTONIC-CRYSTAL FIBER; REFRACTIVE-INDEX; RESONANCE; SENSOR; GRATINGS;
D O I
10.1364/JOSAB.500921
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this paper, a highly sensitive plasmonic photonic crystal fiber (PCF) biosensor is reported for cancer cell detection. The modal analysis of the reported biosensor is performed using the full vectorial finite element method. The suggested PCF sensor has dual V-shaped groves to enhance the sensor sensitivity where two gold nano -rods are mounted on the etched surfaces. The main idea of the optical sensors is to track the electromagnetic coupling between the leaky core mode and the surface plasmon mode (SPM) at the metal/dielectric interface. When the SPM and one of the fundamental core modes are phase -matched, strong coupling occurs. Therefore, maximum confinement loss is achieved for the core -guided mode at the resonance wavelength, which depends on the analyte refractive index (RI). The V-shaped groove enhances the core/SPM coupling where high RI sensitivity of 24,000 nm/RIU is achieved along the RI range from 1.38 to 1.39, with a resolution of 2.703 x 10-6 RIU. The potential of using the suggested RI sensor for cancer cell detection is then demonstrated. In this context, high sensitivities of 23,700 nm/RIU, 8,208 nm/RIU, and 14,428.6 are obtained for basal, cervical, and breast cancer cells with resolutions of 4.22 x 10-6 RIU, 12.18 x 10-6 RIU, and 6.93 x 10-6 RIU, respectively. The achieved sensitivity and resolution are higher than those of the recently reported cancer biosensors. Moreover, the developed label -free biosensor is safer than other chemical and surgical techniques. (c) 2023 Optica Publishing Group
引用
下载
收藏
页码:222 / 229
页数:8
相关论文
共 50 条
  • [31] Multi-wavelength and broadband plasmonic switching with V-shaped plasmonic nanostructures on a VO2 coated plasmonic substrate
    Dalal, Kirti
    Sharma, Yashna
    NANOTECHNOLOGY, 2024, 35 (39)
  • [32] Dual-Core Dual-Polished PCF-SPR Sensor for Cancer Cell Detection
    Sardar, Md. Ranju
    Faisal, Mohammad
    IEEE SENSORS JOURNAL, 2024, 24 (07) : 9843 - 9854
  • [33] Adrenal Glands Cancer Detection using PCF-based Biosensor
    Jibon, Rayhan Habib
    Podder, Etu
    Bulbul, Abdullah Al-Mamun
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON ELECTRONICS, COMMUNICATIONS AND INFORMATION TECHNOLOGY 2021 (ICECIT 2021), 2021,
  • [34] Enhanced tunability of V-shaped plasmonic structures using ionic liquid gating and graphene
    Ozdemir, Onur
    Aygar, A. Melis
    Balci, Osman
    Kocabas, Coskun
    Caglayan, Humeyra
    Ozbay, Ekmel
    CARBON, 2016, 108 : 515 - 520
  • [35] Full day modelling of V-shaped organic solar cell
    Andersson, B. Viktor
    Wuerfel, Uli
    Inganas, Olle
    SOLAR ENERGY, 2011, 85 (06) : 1257 - 1263
  • [36] Cancer and cholesterol: understanding the V-shaped association in patients with diabetes
    Ding, Eric L.
    Hu, Frank B.
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2008, 179 (05) : 403 - 404
  • [37] Microfluidic Plasmonic Biosensor for Breast Cancer Antigen Detection
    Johny Paulo Monteiro
    Jean Halison de Oliveira
    Eduardo Radovanovic
    Alexandre Guimarães Brolo
    Emerson Marcelo Girotto
    Plasmonics, 2016, 11 : 45 - 51
  • [38] Microfluidic Plasmonic Biosensor for Breast Cancer Antigen Detection
    Monteiro, Johny Paulo
    de Oliveira, Jean Halison
    Radovanovic, Eduardo
    Brolo, Alexandre Guimares
    Girotto, Emerson Marcelo
    PLASMONICS, 2016, 11 (01) : 45 - 51
  • [39] Miniaturized Dual-band V-Shaped Monopole Antenna fed by V-Stub
    Chawanonphithak, Yuktitath
    2016 INTERNATIONAL ELECTRICAL ENGINEERING CONGRESS, IEECON2016, 2016, : 43 - 46
  • [40] Design of a dual band V-shaped patch antenna using shorting posts
    Borah, Pranjal
    Bhattacharyya, Satyajib
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2016, 58 (02) : 376 - 378