Investigation of Optimal Light Source Wavelength for Cuffless Blood Pressure Estimation Using a Single Photoplethysmography Sensor

被引:3
|
作者
Toda, Sogo [1 ]
Matsumura, Kenta [2 ]
机构
[1] Natl Inst Technol, Ishikawa Coll, Tsubata 9290392, Japan
[2] Univ Toyama, Fac Med, Toyama 9300194, Japan
关键词
blood pressure; heart rate; modified normalized pulse volume; optical wavelength; photoplethysmography; PULSE TRANSIT-TIME; HEART-RATE; OPTICAL-PROPERTIES; PROGNOSTIC VALUE; HYPERTENSION; VARIABILITY; RESPONSES; FINGER; VOLUME; RANGE;
D O I
10.3390/s23073689
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Routine blood pressure measurement is important for the early detection of various diseases. Recently, cuffless blood pressure estimation methods that do not require cuff pressurization have attracted attention. In this study, we investigated the effect of the light source wavelength on the accuracy of blood pressure estimation using only two physiological indices that can be calculated with photoplethysmography alone, namely, heart rate and modified normalized pulse volume. Using a newly developed photoplethysmography sensor that can simultaneously measure photoplethysmograms at four wavelengths, we evaluated its estimation accuracy for systolic blood pressure, diastolic blood pressure, and mean arterial pressure against a standard cuff sphygmomanometer. Mental stress tasks were used to alter the blood pressure of 14 participants, and multiple linear regression analysis showed the best light sources to be near-infrared for systolic blood pressure and blue for both diastolic blood pressure and mean arterial pressure. The importance of the light source wavelength for the photoplethysmogram in cuffless blood pressure estimation was clarified.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Single-source PPG-based local pulse wave velocity measurement: a potential cuffless blood pressure estimation technique
    Nabeel, P. M.
    Jayaraj, J.
    Mohanasankar, S.
    PHYSIOLOGICAL MEASUREMENT, 2017, 38 (12) : 2122 - 2140
  • [42] Using machine learning models for cuffless blood pressure estimation with ballistocardiogram and impedance plethysmogram
    Liu, Shing-Hong
    Sun, Yao
    Wu, Bo-Yan
    Chen, Wenxi
    Zhu, Xin
    FRONTIERS IN DIGITAL HEALTH, 2025, 7
  • [43] Noninvasive Cuffless Blood Pressure Estimation Using Pulse Transit Time and Impedance Plethysmography
    Toan Huu Huynh
    Jafari, Roozbeh
    Chung, Wan-Young
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (04) : 967 - 976
  • [44] A h-Shirt-Based Body Sensor Network for Cuffless Calibration and Estimation of Arterial Blood Pressure
    Gu, W. B.
    Poon, C. C. Y.
    Sy, M. Y.
    Leung, H. K.
    Liang, Y. P.
    Zhang, Y. T.
    SIXTH INTERNATIONAL WORKSHOP ON WEARABLE AND IMPLANTABLE BODY SENSOR NETWORKS, PROCEEDINGS, 2009, : 151 - 155
  • [45] Estimation of Arterial Blood Pressure Based on Artificial Intelligence Using Single Earlobe Photoplethysmography during Cardiopulmonary Resuscitation
    Jong-Uk Park
    Dong-Won Kang
    Urtnasan Erdenebayar
    Yoon-Ji Kim
    Kyoung-Chul Cha
    Kyoung-Joung Lee
    Journal of Medical Systems, 2020, 44
  • [46] Cuffless Blood Pressure Estimation Using Pulse Transit Time and Photoplethysmogram Intensity Ratio
    Gholamhosseini, Hamid
    Baig, Mirza
    Rastegar, Solmaz
    Linden, Maria
    PROCEEDINGS OF THE 15TH INTERNATIONAL CONFERENCE ON WEARABLE MICRO AND NANO TECHNOLOGIES FOR PERSONALIZED HEALTH (PHEALTH 2018), 2018, 249 : 77 - 83
  • [47] Estimation of Arterial Blood Pressure Based on Artificial Intelligence Using Single Earlobe Photoplethysmography during Cardiopulmonary Resuscitation
    Park, Jong-Uk
    Kang, Dong-Won
    Erdenebayar, Urtnasan
    Kim, Yoon-Ji
    Cha, Kyoung-Chul
    Lee, Kyoung-Joung
    JOURNAL OF MEDICAL SYSTEMS, 2019, 44 (01)
  • [48] A 73μW single channel Photoplethysmography-based Blood Pressure Estimation Processor
    Rehman, Abdul
    Bin Altaf, Muhammad Awais
    Saadeh, Wala
    2022 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS 22), 2022, : 2318 - 2322
  • [49] Fair non-contact blood pressure estimation using imaging photoplethysmography
    Fang, Hongli
    Xiong, Jiping
    He, Linying
    BIOMEDICAL OPTICS EXPRESS, 2024, 15 (04): : 2133 - 2151
  • [50] Performance comparison of machine learning algorithms for the estimation of blood pressure using photoplethysmography
    Di Nisio, Attilio
    De Palma, Luisa
    Ragolia, Mattia Alessandro
    Lanzolla, Anna Maria Lucia
    Attivissimo, Filippo
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2025, 99