New generation of superior single plating vs. low-profile dual minifragment plating in diaphyseal clavicle fractures: a biomechanical comparative study

被引:2
|
作者
Pastor, Tatjana [1 ,2 ]
Zderic, Ivan [1 ]
Berk, Till [3 ]
Souleiman, Firas [4 ]
Vogelin, Esther [2 ]
Beeres, Frank J. P. [5 ]
Gueorguiev, Boyko [1 ]
Pastor, Torsten [5 ,6 ]
机构
[1] AO Res Inst Davos, Davos, Switzerland
[2] Univ Bern, Inselspital Univ Hosp Bern, Dept Plast & Hand Surg, Bern, Switzerland
[3] Univ Hosp Zurich, Dept Trauma, Zurich, Switzerland
[4] Univ Hosp Leipzig, Dept Orthopaed Trauma & Plast Surg, Leipzig, Germany
[5] Lucerne Cantonal Hosp, Dept Orthopaed & Trauma Surg, Luzern, Switzerland
[6] Cantonal Hosp Lucerne, Dept Orthoped & Trauma Surg, Spitalstr 16,POB 6000, CH-6000 Luzern, Switzerland
关键词
Midshaft/diaphyseal clavicle fracture; dual plating; minifragment plates; biomechanics; motion tracking; implant removal; FIXATION;
D O I
10.1016/j.jse.2023.08.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
<bold>Background: </bold>Recently, a new generation of superior clavicle plates was developed featuring the variable-angle locking technology for enhanced screw positioning and a less prominent and optimized plate-to-bone fit design. On the other hand, minifragment plates in dual plating mode have demonstrated promising clinical results. The aim of the current study was to compare the biomechanical competence of single superior plating using the new-generation plate vs. dual plating using low-profile minifragment plates. <bold>Methods: </bold>Sixteen paired human cadaveric clavicles were pairwise assigned to 2 groups for instrumentation with either a superior 2.7-mm variable-angle locking compression plate (group 1), or with one 2.5-mm anterior combined with one 2.0-mm superior matrix mandible plate (group 2). An unstable clavicle shaft fracture (AO/OTA 15.2C) was simulated by means of a 5-mm osteotomy gap. Specimens were cyclically tested to failure under craniocaudal cantilever bending, superimposed with bidirectional torsion around the shaft axis, and monitored via motion tracking. <bold>Results: </bold>Initial construct stiffness was significantly higher in group 2 (9.28 +/- 4.40 N/mm) compared to group 1 (3.68 +/- 1.08 N/mm), P = .003. The amplitudes of interfragmentary motions in terms of axial and shear displacement, fracture gap opening and torsion, over the course of 12,500 cycles were significantly higher in group 1 compared to group 2, P <= .038. Cycles to 2 mm shear displacement were significantly lower in group 1 (22,792 +/- 4346) compared to group 2 (27,437 +/- 1877), P = .047. <bold>Conclusion: </bold>From a biomechanical perspective, low-profile 2.5/2.0-mm dual plates could be considered as a useful alternative for diaphyseal clavicle fracture fixation, especially in less common unstable fracture configurations.
引用
收藏
页码:409 / 416
页数:8
相关论文
共 26 条
  • [21] Intramedullary nailing vs. palmar locked plating for unstable dorsally comminuted distal radius fractures: A biomechanical study
    Burkhart, Klaus J.
    Nowak, Tobias E.
    Gradl, Georg
    Klitscher, Daniela
    Mehling, Isabella
    Mehler, Dorothea
    Mueller, Lars P.
    Rommens, Pol M.
    CLINICAL BIOMECHANICS, 2010, 25 (08) : 771 - 775
  • [22] Anteroinferior versus superior plating techniques for displaced midshaft clavicle fractures: A retrospective single centre cohort study from Northern Nigeria
    Arojuraye, S. A.
    Salihu, M. N.
    Mustapha, I. U.
    Alabi, I. A.
    Okoh, N.
    Ayeni, F. B.
    SURGEON-JOURNAL OF THE ROYAL COLLEGES OF SURGEONS OF EDINBURGH AND IRELAND, 2022, 20 (05): : E248 - E253
  • [23] Locking Reconstruction Double Plating of Distal Humeral Fractures: How Many Screws in the Distal Ulnar Column Segment in A3 Fracture Provide Superior Stability? A Comparative Biomechanical In Vitro Study
    Mehling, Isabella
    Schmidt-Horlohe, Kay
    Mueller, Lars Peter
    Sternstein, Werner
    Korner, Jan
    Rommens, Pol Maria
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (08) : 581 - 587
  • [24] Clinical and functional outcomes of locked plating vs. cerclage compression wiring for AO type C patellar fractures- a retrospective single-center cohort study
    Bickel, Steven
    Jensen, Kai Oliver
    Klingebiel, Felix Karl-Ludwig
    Teuben, Michel Paul Johan
    Pfeifer, Roman
    Pape, Hans-Christoph
    Hierholzer, Christian
    Kalbas, Yannik
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2024, 50 (06) : 2975 - 2985
  • [25] Medium-Term Outcomes of Stent Therapy for Aortic Coarctation in Children Under 30 kg with New Generation Low-Profile Stents: A Follow-Up Study of a Single Centre Experience
    Gibb, Jack J. C.
    Kim, Wan Cheol
    Barlatay, Francisco Gonzalez
    Tometzki, Andrew
    Pateman, Alan
    Caputo, Massimo
    Taliotis, Demetris
    PEDIATRIC CARDIOLOGY, 2024, 45 (03) : 544 - 551
  • [26] Medium-Term Outcomes of Stent Therapy for Aortic Coarctation in Children Under 30 kg with New Generation Low-Profile Stents: A Follow-Up Study of a Single Centre Experience
    Jack J. C. Gibb
    Wan Cheol Kim
    Francisco Gonzalez Barlatay
    Andrew Tometzki
    Alan Pateman
    Massimo Caputo
    Demetris Taliotis
    Pediatric Cardiology, 2024, 45 : 544 - 551