Novel configuration of dual-temperature condensation and dual-temperature evaporation high-temperature heat pump system: Carbon footprint, energy consumption, and financial assessment

被引:33
|
作者
Dai, Baomin [1 ]
Wang, Qi [1 ]
Liu, Shengchun [1 ]
Wang, Dabiao [2 ]
Yu, Liqi [1 ]
Li, Xinhai [1 ]
Wang, Yuanyuan [1 ]
机构
[1] Tianjin Univ Commerce, Tianjin Key Lab Refrigerat Technol, Tianjin 300134, Peoples R China
[2] Fuzhou Univ, Natl Engn Res Ctr Chem Fertilizer Catalyst NERC CF, Sch Chem Engn, Fujian 350002, Peoples R China
关键词
High-temperature heat pump; Ejector; Dual-temperature condensation; Dual-temperature evaporation; Temperature matching; Waste heat recovery; CO2 REFRIGERATION CYCLE; LOW-GWP REFRIGERANTS; PERFORMANCE ANALYSIS; WORKING; R1234ZE(Z);
D O I
10.1016/j.enconman.2023.117360
中图分类号
O414.1 [热力学];
学科分类号
摘要
To achieve the goal of carbon neutrality for the application of industrial heating by recovery waste heat, the concept of dual-temperature condensation and dual-temperature evaporation is proposed for the hightemperature heat pump (HTHP) by introducing the techniques of ejector and two-stage compression. The energy, exergy, emission, and economic models are developed and optimized for the two new proposed systems. Then, the energy consumption, CO2 emissions and cost (LCC) during the whole life cycle are compared with five existing heat pumps and four traditional boilers. The highest coefficient of performance (COP) of heat pump (HP) can be got when intermediate water temperature on the heat sink side is optimum. The new proposed systems have better performances than the other five HTHPs. During the rated working condition, discharge temperature decreases by the use of dual-temperature condensation and dual-temperature evaporation HP with an ejector (EjDCDE). The optimal COP of Ej-DCDE-2 is 4.25, which is 11.55% and 1.43% higher than dual-temperature condensation and single-temperature evaporation HP and Ej-DCDE-1, respectively. The exergy destruction of Ej-DCDE-2 is reduced by 27.88% compared with basic heat pump (Base). Moreover, Ej-DCDE-2 has the lowest primary energy consumption of 14.62 ktoe, 22.19% and 25.09% lower than Base and oil-fired boiler during the total working period, respectively. In general, HTHPs have lower carbon dioxide, gaseous and particular pollutant emissions compared with boilers, especially Ej-DCDE-2. Finally, Ej-DCDE-2 has the minimum LCC, which is 14.67% and 11.75% less than Base and coal-fired boiler. Ej-DCDE-2 shows the most potential advantages of all the heating solutions and is recommended to replace traditional boilers for industrial heating.
引用
收藏
页数:25
相关论文
共 50 条
  • [41] An optimal design method for a heat exchanger for a dual-stage circulating high-temperature heat pump system
    Zhao, Tianyi
    Zhang, Jili
    Ma, Liangdong
    APPLIED THERMAL ENGINEERING, 2013, 61 (02) : 698 - 715
  • [42] Thermodynamic analysis of two-stage and dual-temperature ejector refrigeration cycles driven by the waste heat of exhaust gas
    Liang, Youcai
    Ye, Kai
    Zhu, Yan
    Lu, Jidong
    ENERGY, 2023, 278
  • [43] Thermodynamic and economic evaluation of a non-cascaded dual-temperature compression-absorption-resorption refrigeration system
    Kumar, Anil
    Modi, Anish
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [44] Experimental research on the concentration distribution characteristics of dual-temperature refrigeration system using R290/R600a based on separation condensation
    Chen, Qi
    Yan, Gang
    Yu, Jianlin
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 131 : 244 - 253
  • [45] Thermodynamic analysis of a dual-pressure evaporation high-temperature heat pump with low GWP zeotropic mixtures for steam generation
    Feng, Chunyu
    Guo, Cong
    Chen, Junbin
    Tan, Sicong
    Jiang, Yuyan
    ENERGY, 2024, 294
  • [46] Performance assessment of a waste-heat driven CO2-based combined power and refrigeration cycle for dual-temperature refrigerated truck application
    Pan, Mingzhang
    Zhu, Yan
    Liang, Youcai
    Lu, Fulu
    Zhi, Ruiping
    Xiao, Gang
    ENERGY CONVERSION AND MANAGEMENT, 2021, 249
  • [47] Dual coating system for pipelines in high-temperature service
    Cox, J.W.
    Fogh, Ken
    Materials Performance, 1990, 29 (10) : 18 - 21
  • [48] Mathematical-Experimental Assessment of Energy Efficiency of High-Temperature Heat Pump Distiller
    I. I. Malafeev
    G. A. Il’in
    V. B. Sapozhnikov
    Chemical and Petroleum Engineering, 2019, 55 : 556 - 561
  • [49] Mathematical-Experimental Assessment of Energy Efficiency of High-Temperature Heat Pump Distiller
    Malafeev, I. I.
    Il'in, G. A.
    Sapozhnikov, V. B.
    CHEMICAL AND PETROLEUM ENGINEERING, 2019, 55 (7-8) : 556 - 561
  • [50] HIGH-TEMPERATURE HEAT-PUMP BY BINARY REFRIGERATING SYSTEM
    SHIBATA, E
    NAKAKOSHI, T
    MINATO, K